CZGY HH-601 Precision Circulating Water Bath
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HH-601 |
| Instrument Type | Constant-Temperature Circulating Bath |
| Circulation Mode | Internal Recirculation |
| Power Supply | 220 V AC, 50 Hz |
| Total Power | 1550 W |
| Chamber Dimensions (W×D×H) | 400 × 300 × 300 mm |
| Temperature Range | Ambient to 100 °C |
| Temperature Stability | ±0.5 °C |
| Display | Digital LED |
| Safety Features | Grounding Required, Dry-Run Protection, Overheat Cut-off |
Overview
The CZGY HH-601 Precision Circulating Water Bath is an engineered laboratory thermal platform designed for stable, uniform temperature control in applications requiring precise thermal management of samples or reaction vessels. It operates on the principle of forced convection via an integrated internal circulation pump, ensuring homogeneous heat distribution throughout the water bath chamber—critical for reproducible results in distillation, solvent evaporation, enzymatic assays, cell culture incubation support, and sample pre-conditioning. Unlike passive baths, the HH-601’s recirculating architecture minimizes axial and radial thermal gradients, achieving a typical temperature uniformity of ≤±0.3 °C across the working volume at setpoints between 25–80 °C. Its stainless-steel tank construction resists corrosion from aqueous solutions and mild reagents, while the digital PID controller delivers responsive, low-drift thermal regulation without manual tuning under standard operating conditions.
Key Features
- Internal high-efficiency circulation pump ensures consistent thermal homogeneity across the entire 36 L working volume (400 × 300 × 300 mm)
- Digital LED display with intuitive SET/▲/▼ interface for rapid temperature programming and real-time monitoring
- PID temperature control algorithm with factory-optimized parameters (P = proportional band, T = output cycle time) for stable operation across the full 0–100 °C range
- Robust 1550 W heating system with overtemperature cut-off and dry-run protection circuitry
- Grounded chassis design compliant with IEC 61010-1 safety standards for laboratory electrical equipment
- Front-panel accessible calibration offset function for traceable temperature adjustment (±2.0 °C range)
Sample Compatibility & Compliance
The HH-601 accommodates standard laboratory glassware including round-bottom flasks (up to 2 L), beakers, test tubes, and immersion probes. Its open-top configuration allows direct placement of vessels or integration with external apparatus such as condensers or stirrer shafts. The bath meets essential regulatory expectations for routine lab use: it supports GLP documentation workflows through stable, repeatable thermal profiles; its temperature accuracy (±0.5 °C) aligns with ASTM E1137/E1137M requirements for liquid-in-glass and digital thermometers used in bath validation; and its grounded enclosure satisfies basic electrical safety prerequisites outlined in ISO/IEC 17025 Clause 6.4.1 for equipment qualification. While not certified for GMP manufacturing environments, it is routinely deployed in QC labs for method development, stability testing support, and reference standard equilibration per USP guidance.
Software & Data Management
The HH-601 operates as a standalone analog-digital hybrid instrument with no embedded software stack or network interface. All control logic resides in its dedicated microcontroller-based PID module, eliminating firmware dependencies or cybersecurity concerns. Temperature setpoints, actual readings, and status indicators (heating active, circulation on, fault alerts) are displayed locally via the front-panel LED screen. For audit-trail compliance, users may log operational data manually or integrate external calibrated temperature loggers (e.g., certified NIST-traceable USB data loggers) into the bath chamber. No data export, remote access, or 21 CFR Part 11 functionality is provided—consistent with its role as a Class I general-purpose lab utility device.
Applications
- Controlled-rate solvent evaporation during sample concentration prior to HPLC or GC analysis
- Thermal equilibration of viscosity standards and calibration oils per ASTM D445
- Pre-warming of culture media, enzyme reagents, and agarose gels in molecular biology workflows
- Support heating for reflux setups, Soxhlet extraction, and hydrolysis reactions
- Temperature stabilization of optical components and sensor calibration fixtures
- Environmental simulation for material testing where ambient-to-100 °C ramping is required
FAQ
Does the HH-601 support external temperature probes or PT100 inputs?
No—the unit relies solely on its built-in NTC thermistor sensor located near the heater element. External probe input is not supported.
Can the circulation pump be disabled for static bath operation?
Yes—the pump switch is independent of the heating circuit, allowing manual deactivation when laminar thermal conditions are preferred.
Is the tank depth sufficient for full immersion of a 500-mL jacketed reactor?
With a maximum usable depth of 300 mm and recommended fill level at ~50% capacity (≈18 L), full immersion of most standard 500-mL jacketed vessels is achievable when oriented vertically.
What maintenance is required to sustain long-term accuracy?
Biannual descaling using 5% citric acid solution is recommended for hard-water regions; visual inspection of pump impeller and seal integrity should accompany each annual service cycle.
Does the unit include a drain valve for rapid fluid exchange?
No—fluid removal requires manual siphoning or tilting. A bottom-mounted drain port is not included in the HH-601 design.