Parker Domnick Hunter UHP-10ZA-S Zero Air Generator
| Brand | Parker DH |
|---|---|
| Origin | United Kingdom |
| Model | UHP-10ZA-S, UHP-35ZA-S, UHP-50ZA-S, UHP-75ZA-S, UHP-150ZA-S, UHP-200ZA-S, UHP-300ZA-S |
| Hydrocarbon Content | < 0.1 ppm |
| Output Flow Rate | 1.0–30.0 L/min |
| Dew Point | ≤ –40 °C (typical, after integrated drying) |
| Inlet Connection | 1/8″ or 1/4″ Swagelok® |
| Outlet Connection | 1/8″ or 1/4″ Swagelok® |
| Dimensions (W×H×D) | 340 × 455 × 425 mm (UHP-10ZA-S to UHP-75ZA-S) |
| Weight | 10.2–14.2 kg |
| Filtration Stages | OIL-X EVOLUTION A0 (coalescing), catalytic oxidation unit, OIL-X EVOLUTION AA (0.01 µm final particulate) |
Overview
The Parker Domnick Hunter UHP-10ZA-S Zero Air Generator is an engineered solution for laboratories requiring continuous, high-purity air supply with hydrocarbon content below 0.1 ppm — meeting the stringent demands of flame-based gas chromatography detectors (FID, FPD, NPD), LC/MS nebulizer and exhaust gas systems, total hydrocarbon analyzers, and calibration/dilution applications in gas-sensing instrumentation. Unlike compressed air cylinders or non-catalytic purifiers, this generator employs a three-stage purification architecture: first, coalescing filtration via the OIL-X EVOLUTION A0-grade filter removes oil aerosols, water vapor, and particulates down to 0.01 µm; second, catalytic oxidation at precisely controlled temperature converts residual hydrocarbons into CO₂ and H₂O; third, a final OIL-X EVOLUTION AA 0.01 µm particulate filter ensures removal of any post-catalysis solids. Integrated thermal monitoring of the catalytic bed guarantees consistent reaction kinetics and full hydrocarbon abatement across variable ambient conditions and load profiles.
Key Features
- Continuous zero-air generation from existing compressed air infrastructure — eliminates dependency on high-pressure cylinder logistics and associated safety risks.
- Catalytic oxidation system with real-time temperature monitoring and display, ensuring optimal conversion efficiency and traceable purity assurance.
- Modular, space-efficient footprint (340 × 455 × 425 mm) designed for benchtop integration or under-bench mounting; compatible with Parker Domnick Hunter UHP hydrogen generators via standardized top-plate interconnection.
- Swagelok®-compatible 1/8″ or 1/4″ inlet/outlet ports facilitate leak-tight, vibration-resistant connections to analytical instruments and gas distribution manifolds.
- Low-maintenance design: annual filter replacement only (A0 + AA stages), completed in under five minutes without tools or system depressurization.
- Stable output pressure and flow control across full operating range (1.0–30.0 L/min), supporting multi-instrument distribution with minimal pressure drop.
Sample Compatibility & Compliance
The UHP-10ZA-S series delivers air compliant with ASTM D6216 (Standard Specification for Zero Air Used in Ambient Air Monitoring), ISO 8573-1 Class 1:1:1 (for particles, water, and oil), and USP requirements for residual hydrocarbons in analytical gas supplies. Its validated hydrocarbon removal performance (< 0.1 ppm total C₁–C₆) satisfies detector-specific specifications for GC-FID baseline stability and signal-to-noise ratio. The system supports GLP/GMP environments through documented maintenance intervals, calibrated temperature monitoring, and compatibility with audit-trail-capable laboratory information management systems (LIMS) when integrated via analog or digital I/O modules (optional). No consumables beyond scheduled filters are required — eliminating variability introduced by cylinder lot-to-lot inconsistencies.
Software & Data Management
While the UHP-10ZA-S operates as a standalone hardware platform without embedded firmware or touchscreen interface, it provides analog voltage outputs (0–10 VDC) corresponding to catalytic bed temperature — enabling connection to external data loggers, SCADA systems, or LIMS for continuous environmental monitoring and preventive maintenance scheduling. Optional RS-485 Modbus RTU communication module (UHP-COMM-RTU) allows remote status interrogation (temperature, flow fault, filter life countdown) and integration into centralized lab gas management platforms. All operational parameters adhere to IEC 61000-6-2 (immunity) and IEC 61000-6-4 (emissions) standards, ensuring electromagnetic compatibility within instrument-dense analytical suites.
Applications
- Flame ionization detection (FID), flame photometric detection (FPD), and nitrogen-phosphorus detection (NPD) in gas chromatography — providing stable, low-noise combustion gas with reproducible response factors.
- Nebulizer and curtain gas supply for liquid chromatography–mass spectrometry (LC/MS), where hydrocarbon contamination directly impacts ion suppression and long-term source cleanliness.
- Zero-air reference and fuel gas for total hydrocarbon analyzers (THCA) and photoionization detectors (PID), ensuring accurate calibration traceability against certified standards.
- Dilution and calibration gas generation for environmental air quality monitors (e.g., ozone, NOₓ, SO₂ analyzers) operating per EPA Methods 25A and 25B.
- Carrier and purge gas in elemental analyzers, thermal desorption units, and headspace samplers requiring ultra-low organic background.
FAQ
What compressed air quality is required for optimal UHP-10ZA-S performance?
The generator requires inlet air meeting ISO 8573-1 Class 4:4:4 (oil ≤ 1 mg/m³, particles ≤ 15 µm, dew point ≤ +3 °C) — typically achieved using a refrigerated dryer and basic coalescing pre-filter upstream of the unit.
Can multiple instruments be supplied from a single UHP-300ZA-S unit?
Yes — provided total demand remains within the 30.0 L/min maximum flow and pressure drop across the distribution manifold does not exceed 10 psi at peak draw; use stainless steel or electropolished tubing and calibrated flow restrictors to maintain instrument-specific flow rates.
Is catalytic converter replacement required during normal operation?
No — the palladium-platinum catalyst is engineered for >10,000 hours of continuous service under specified inlet conditions; lifetime is extended by upstream A0 filtration and thermal stabilization.
How is compliance with regulatory documentation verified?
Each unit ships with a Certificate of Conformance referencing ASTM D6216 and ISO 8573-1; optional factory calibration report includes hydrocarbon testing per EPA TO-15 methodology using GC-FID validation.
Does the UHP-10ZA-S support 24/7 unattended operation?
Yes — it features thermal overload protection, pressure relief valves, and fail-safe shutdown logic triggered by catalytic temperature deviation exceeding ±5 °C of setpoint; suitable for automated labs operating under 21 CFR Part 11-compliant workflows when paired with appropriate data logging infrastructure.