Empowering Scientific Discovery

Gangdong Zhiview Smart Fourier Transform Infrared Spectrometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Gangdong
Origin Tianjin, China
Manufacturer Type Manufacturer
Product Type Domestic
Model Zhiview Smart
Price Range USD 14,000–21,000 (FOB)
Instrument Category Fourier Transform Type
Form Factor Portable
Wavenumber Range 7800–350 cm⁻¹
Resolution 1 cm⁻¹
Scan Speed Software-selectable via PC control
Signal-to-Noise Ratio 20,000:1 (peak-to-peak, 4 cm⁻¹, 1-min scan at 2100 cm⁻¹)

Overview

The Gangdong Zhiview Smart Fourier Transform Infrared (FTIR) Spectrometer is a compact, benchtop-grade analytical instrument engineered for precision mid-infrared spectroscopy in resource-constrained or mobile laboratory environments. Based on Michelson interferometry with a dynamically aligned moving mirror and fixed retroreflector design, the system acquires interferograms digitized at high fidelity and transforms them into absorbance/transmittance spectra using fast Fourier transformation algorithms. Its optical architecture centers on a thermoelectrically stabilized, permanently aligned aluminum optical bench—eliminating field-service alignment requirements and ensuring long-term wavenumber accuracy and photometric repeatability across extended operational cycles. Designed to meet the functional demands of regulated and academic settings alike, the Zhiview Smart delivers laboratory-grade spectral performance without the footprint or infrastructure dependency of conventional FTIR platforms.

Key Features

  • Compact, Space-Efficient Design: Dimensions of 355 × 265 × 160 mm and mass of 9.6 kg enable deployment on crowded lab benches, inside fume hoods, or transport between sampling sites—ideal for quality control in manufacturing cleanrooms or field-based environmental screening.
  • Monolithic Gold-Coated Corner Cube Retroreflector: Precision-machined from solid aluminum and coated with high-reflectivity gold (R > 98% across 7800–350 cm⁻¹), the corner cube eliminates adhesive-based assembly, mitigating thermal drift and mechanical hysteresis under ambient temperature fluctuations.
  • 24-Bit Analog-to-Digital Conversion & Pyroelectric Detection: Paired with a low-noise, wide-dynamic-range pyroelectric detector (imported), the system achieves real-time spectral acquisition with minimal quantization error and high temporal resolution—critical for kinetic studies or rapid sample throughput.
  • Integrated Humidity Mitigation System: Combines a hermetically sealed interferometer housing, desiccant status indicator window, and anti-hydrolysis KBr beam splitter (germanium-coated, moisture-resistant), extending operational uptime in high-humidity climates without routine purging.
  • Modular Accessory Interface: Standardized mounting rails support quick-swap integration of ATR accessories (push-fit single-reflection diamond/ZnSe), gas cells (10 cm pathlength, CaF₂ windows), liquid transmission cells (demountable, 0.1–1.0 mm spacers), and KBr pellet holders—enabling method transfer across solid, liquid, and gaseous phases.
  • Regulatory-Ready Software Architecture: Embedded audit trail functionality with time-stamped, user-identified event logging; role-based access control (three-tier permissions: Admin, Operator, Reviewer); electronic signature support compliant with 21 CFR Part 11 principles for pharmaceutical and clinical labs.

Sample Compatibility & Compliance

The Zhiview Smart supports qualitative and quantitative analysis of organic and inorganic compounds across diverse matrices—including APIs, polymers, catalysts, soils, aqueous extracts, and volatile organics. Its 7800–350 cm⁻¹ spectral range covers fundamental C–H, O–H, N–H, C=O, C–O, and Si–O stretching/bending modes essential for structural elucidation per ASTM E1252, ISO 18381, and USP . The instrument meets GLP/GMP documentation requirements through traceable calibration (NIST-traceable polystyrene film validation), linearity verification (<0.1% deviation in 4400–500 cm⁻¹ region excluding atmospheric H₂O/CO₂ bands), and reproducibility testing (RSD < 0.5% for peak intensity over 10 consecutive scans). Optional IQ/OQ/PQ documentation packages are available to support full 3Q validation per ISO/IEC 17025 and FDA guidance.

Software & Data Management

Bundled with Gangdong’s proprietary IRSoft v5.x platform (Windows XP/7/10 compatible), the spectrometer provides intuitive spectral acquisition, baseline correction (Rubberband, Concave), peak search/assignment (integrated Sadtler library), multivariate analysis (PCA, PLS), and customizable report generation. All raw interferograms and processed spectra are stored in vendor-neutral .SPA format, fully readable by third-party tools including OMNIC, GRAMS/AI, and Python-based SciPy workflows. Data integrity is enforced via encrypted project files, immutable metadata embedding (instrument ID, operator, date/time, acquisition parameters), and automated backup to network drives or cloud storage endpoints.

Applications

  • Pharmaceutical QC: Identification of excipients, detection of counterfeit drugs, polymorph screening, and residual solvent quantification per ICH Q2(R2).
  • Polymer Characterization: Degree of crystallinity assessment, oxidation index calculation, copolymer composition analysis, and degradation monitoring.
  • Environmental Monitoring: Microplastic identification in water/sediment samples, VOC profiling in air canisters, and soil organic matter fingerprinting.
  • Academic Research: Teaching FTIR fundamentals, reaction monitoring, thin-film thickness estimation (using interference fringes), and surface adsorption studies via in situ ATR.
  • Materials Science: Coating uniformity evaluation, catalyst surface speciation (CO probe molecule adsorption), and graphene oxide reduction tracking.

FAQ

Does the Zhiview Smart require continuous dry-air or nitrogen purging?
No—its sealed interferometer, anti-hydrolysis beam splitter, and visual desiccant indicator reduce dependence on external purge gases. Ambient operation is viable in RH ≤ 70%; for prolonged use above 75% RH, optional desiccant replacement every 6–12 months is recommended.
Is the instrument compatible with LIMS integration?
Yes—IRSoft supports ASTM E1384-compliant data export (CSV, XML) and offers a TCP/IP API for bidirectional communication with major LIMS platforms (e.g., LabWare, Thermo SampleManager, STARLIMS).
What validation documentation is provided out-of-the-box?
Each unit ships with Factory Acceptance Test (FAT) report, Certificate of Conformance, and basic IQ checklist. Full 3Q validation kits—including URS, DQ, IQ/OQ protocols, and PQ test records—are available as add-on services.
Can the software perform quantitative analysis using external calibration standards?
Yes—IRSoft includes built-in calibration curve tools supporting linear, quadratic, and multi-point PLS regression models, with LOD/LOQ estimation per CLSI EP17-A2 guidelines.
Is the ATR accessory included standard or optional?
The push-fit single-reflection diamond ATR module is offered as an optional accessory; ZnSe and Ge variants are also available for specific spectral range or durability requirements.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0