Empowering Scientific Discovery

YiHeng DK-8AXX Triple-Independent Chamber Digital Water Bath

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand YiHeng
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Model DK-8AXX
Temperature Range RT+5°C to 99°C
Bath Volume 15 L per Chamber (3 × 15 L total)
Heating Power 600 W per Chamber
External Dimensions (W×D×H) 460 × 340 × 190 mm
Control System Microprocessor-based Digital PID Controller with Timer Function
Safety Features Over-Temperature Audio-Visual Alarm
Construction Stainless Steel Inner Tank and Lid
Optional Multi-Stage Programmable Controller with Adjustable Circulation Pump Speed and Scheduled Power-On/Off

Overview

The YiHeng DK-8AXX Triple-Independent Chamber Digital Water Bath is an engineered solution for laboratories requiring simultaneous, precise thermal control across three separate aqueous environments. Designed on the principle of resistive heating combined with PID-regulated feedback loops, this water bath maintains stable temperature uniformity within ±0.3°C across each 15-liter stainless steel chamber—enabling parallel sample processing without cross-chamber thermal interference. Its architecture supports both static immersion and dynamic circulation applications, making it suitable for incubation, enzymatic reactions, dissolution testing, and calibration of temperature-sensitive probes. The unit operates in ambient environments ranging from 15°C to 30°C and is rated for continuous duty at temperatures up to 99°C, meeting the thermal stability requirements defined in ISO 17025-accredited laboratory workflows.

Key Features

  • Triple independent chambers—each equipped with dedicated digital PID temperature controller, allowing fully autonomous setpoint configuration (RT+5°C to 99°C) and real-time monitoring.
  • 304 stainless steel inner tanks and lids ensure long-term corrosion resistance, ease of decontamination, and compliance with GLP cleaning validation protocols.
  • Microprocessor-based digital display with intuitive keypad interface; includes built-in timer function (1–999 minutes) and automatic shut-off capability.
  • Over-temperature protection system with audible alarm and visual LED indicator activates when internal sensor detects deviation beyond user-defined safety threshold (default: +5°C above setpoint).
  • Integrated circulation pump (optional speed adjustment) enhances thermal homogeneity and accelerates equilibration time—critical for viscosity standardization and QC sample conditioning.
  • Optional multi-stage programmable controller enables up to 30 segments of time-temperature profiles, supporting complex thermal ramping sequences required in accelerated stability studies (ICH Q1A) and thermal denaturation assays.

Sample Compatibility & Compliance

The DK-8AXX accommodates standard laboratory glassware including beakers (up to Ø150 mm), test tubes, cuvettes, and sample racks—without compromising chamber clearance or thermal response. Its non-porous stainless steel construction complies with USP guidelines for analytical instrument qualification and supports routine IQ/OQ/PQ documentation. The unit meets CE safety standards (EN 61010-1) and is designed for use in ISO Class 5–8 cleanroom-adjacent environments. While not intrinsically rated for hazardous location use, its sealed electronics and grounded chassis satisfy general electrical safety requirements under IEC 61000-6-3 for conducted emissions.

Software & Data Management

The base configuration operates via embedded firmware with no external software dependency—ensuring deterministic response and eliminating cybersecurity vulnerabilities associated with networked controllers. For laboratories implementing 21 CFR Part 11-compliant data integrity frameworks, the optional programmable module logs timestamped temperature readings at user-selectable intervals (1–60 sec), stores up to 10,000 data points internally, and exports CSV files via USB port. Audit trail functionality records all parameter changes—including operator ID input (via alphanumeric keypad), setpoint modifications, and alarm events—with immutable timestamps. Data export supports traceability alignment with FDA-recommended ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Pharmaceutical QC: Dissolution medium conditioning per USP , enzyme assay incubation, and reference standard equilibration prior to HPLC analysis.
  • Life Sciences: Cell culture reagent warming, DNA hybridization baths, and gel electrophoresis buffer temperature stabilization.
  • Materials Testing: Polymer melt conditioning, coating viscosity pre-equilibration, and thermal aging of elastomeric samples.
  • Calibration Labs: Reference thermometer verification using fixed-point cells or certified RTDs in stable thermal fields.
  • Educational Use: Demonstrating Arrhenius kinetics, heat transfer coefficients, and phase transition behavior in undergraduate physical chemistry labs.

FAQ

What is the temperature uniformity specification across each chamber?
Typical uniformity is ±0.3°C at 37°C and ±0.5°C at 95°C, measured at five locations (center + four quadrants) per chamber per ASTM E1112.
Can the circulation pump be disabled for static water bath operation?
Yes—the pump is independently switchable and bypass-capable; static mode is recommended for delicate biological samples sensitive to shear stress.
Is the DK-8AXX compatible with external temperature loggers or SCADA systems?
Analog 4–20 mA output (optional) and RS485 Modbus RTU interface are available for integration into centralized lab monitoring platforms.
Does the unit support GLP audit requirements for electronic records?
With the programmable module installed, full electronic record generation—including operator authentication, change history, and digital signature support—is achievable under validated configurations.
What maintenance procedures are recommended for long-term reliability?
Bi-weekly descaling with 5% citric acid solution, quarterly inspection of silicone gaskets, and annual verification of sensor calibration against NIST-traceable references.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0