DRETOP LX5-60 Low-Temperature Circulating Chiller
| Brand | DRETOP |
|---|---|
| Origin | Shanghai, China |
| Model | LX5-60 |
| Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Range | –60 °C to 100 °C |
| Temperature Stability | ±0.1 °C |
| Circulation Flow Rate | 20 L/min |
| Reservoir Volume | 5 L |
| Operating Mode | Continuous |
| Power Supply | 220 V, 50 Hz |
| Tank Opening Diameter | Φ210 mm |
| Pump Head | 4–6 m |
| Communication Interface | RS485 |
Overview
The DRETOP LX5-60 Low-Temperature Circulating Chiller is a precision-engineered thermal management system designed for laboratory and industrial applications requiring stable, wide-range temperature control of external equipment via closed-loop coolant circulation. Based on vapor-compression refrigeration with integrated electric heating, the unit delivers continuous, bidirectional thermal regulation across a broad operating envelope—from cryogenic –60 °C up to 100 °C—without requiring refrigerant or heat-transfer medium exchange. Its core function is to supply conditioned fluid (e.g., water, 30–50% aqueous ethylene glycol, or specialized low-temperature heat-transfer fluids) at precisely maintained temperatures to external devices such as rotary evaporators, spectrophotometer Peltier modules, HPLC column ovens, laser diode mounts, vacuum deposition chambers, and jacketed reactors. Unlike open-bath systems, the LX5-60 operates exclusively in external circulation mode, eliminating direct sample immersion and enabling seamless integration into automated or GMP-compliant workflows where contamination control, traceability, and process repeatability are critical.
Key Features
- PID-based digital temperature controller with high-resolution Pt100 sensor feedback, achieving ±0.1 °C setpoint stability under steady-state conditions and rapid thermal response (<15 min from –60 °C to 25 °C, typical)
- Hermetically sealed stainless steel reservoir (5 L capacity) and corrosion-resistant internal piping, compatible with common low-temperature heat-transfer media including glycol/water mixtures and silicone oils
- Low-noise, variable-speed hermetic compressor with adaptive load modulation—reducing energy consumption during partial-load operation while maintaining consistent cooling capacity
- Integrated high-efficiency centrifugal circulation pump delivering 20 L/min flow at 4–6 m head, engineered for low self-heating and minimal thermal drift in recirculating loops
- RS485 serial interface compliant with Modbus RTU protocol, supporting remote monitoring, parameter configuration, and time-stamped data logging via PC or SCADA systems
- IP54-rated enclosure with industrial-grade insulation, condensate management, and reinforced cold-side components rated for sustained operation below –40 °C
Sample Compatibility & Compliance
The LX5-60 is not a sample-holding device but a fluid temperature conditioning platform; therefore, compatibility is defined by the thermal and chemical properties of the circulating medium and its interface with connected instrumentation. It supports ASTM D1250-compliant glycol blends, USP-grade water, and other ISO 8573-1 Class 2–3 clean fluids when used with appropriate filtration. The system complies with IEC 61000-6-3 (EMC emission standards) and IEC 61000-6-2 (immunity), and its electrical safety conforms to IEC 61010-1 for laboratory equipment. For regulated environments, optional audit-trail-enabled firmware (with user access logs, parameter change history, and electronic signature support) aligns with FDA 21 CFR Part 11 and EU Annex 11 requirements when deployed in GLP/GMP settings—for example, in biopharmaceutical stability chambers or semiconductor process tool cooling.
Software & Data Management
The LX5-60 includes embedded firmware with real-time display of setpoint, actual bath temperature, compressor status, pump RPM, and fault codes. Through the RS485 port, users may connect to third-party software platforms—including LabVIEW, MATLAB, or custom Python-based DAQ systems—using standard Modbus register mapping. Logged data (temperature vs. time, alarm events, runtime hours) can be exported in CSV format. Optional DRETOP ThermalLink™ desktop application provides graphical trend analysis, multi-channel synchronization (when cascading multiple chillers), and automated report generation compliant with ISO/IEC 17025 documentation requirements. All data timestamps are synchronized to UTC via NTP if connected to an Ethernet gateway (not included).
Applications
- Cooling condenser jackets of rotary evaporators processing low-boiling solvents (e.g., diethyl ether, pentane) requiring sub-zero dewpoint control
- Thermal stabilization of analytical instruments: CCD detectors in Raman spectrometers, capillary electrophoresis modules, and GC oven heat sinks
- Temperature control of semiconductor fabrication tools—including plasma etchers and sputtering sources—where thermal drift directly impacts film uniformity
- Supplying chilled fluid to jacketed glass reactors (1–20 L volume) for exothermic Grignard, lithiation, or nitration reactions requiring precise –30 °C to 0 °C control
- Supporting cryo-microscopy sample stages, superconducting magnet cryocooler pre-cooling circuits, and low-temperature material characterization rigs
- Integration into pilot-scale continuous manufacturing lines per ICH Q5C and Q8(R2) guidelines, where chiller performance qualification (PQ) is documented per ISO 13485
FAQ
What types of heat-transfer fluids are recommended for operation below –40 °C?
Ethylene glycol/water mixtures (e.g., 50/50 v/v) or synthetic hydrocarbon-based coolants (e.g., Shell Therminol VP-1) are validated for continuous use down to –60 °C. Pure water is prohibited below 0 °C.
Can the LX5-60 be used for heating-only applications without refrigeration?
Yes—the integrated tubular heater enables standalone heating mode up to 100 °C, with independent PID control and overtemperature cutoff.
Is external pressure relief required for closed-loop systems?
Yes. A pressure-relief valve rated ≥3 bar must be installed upstream of the chiller’s inlet per ASME B31.9 and local plumbing codes when used with pressurized reactor jackets.
Does the unit support dual-temperature zoning (e.g., simultaneous –20 °C and +60 °C outputs)?
No. The LX5-60 is a single-loop system. Dual-zone control requires two independent units or a higher-tier HLX-series integrated chiller.
What maintenance intervals are recommended for extended service life?
Compressor oil and refrigerant integrity should be verified annually; pump impeller and seal inspection is advised every 2,000 operating hours; reservoir cleaning and fluid replacement every 6 months under continuous operation.



