Empowering Scientific Discovery

WIGGENS WH-01 Miniature Peltier-Cooled Biochemical Incubator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand WIGGENS
Origin Germany
Model WH-01
Temperature Range +4 to 60 °C (at 20 °C ambient)
Temperature Fluctuation ±0.1 °C
Temperature Uniformity < ±0.6 °C at 37 °C and 25 °C RT
External Dimensions (W×D×H) 400 × 409.5 × 445 mm
Cooling Method Solid-State Peltier System
Heating Method Stainless Steel Air-Jacket Heater
Control System TFT Touchscreen with PID Algorithm
Programmability 4 multi-step temperature ramps (5 segments each)
Fan Speed Control 0–100% continuous adjustment
Timer Range 1 min – 999 hr 59 min
Power Supply AC 220–240 V, 50/60 Hz
Net Weight 24 kg

Overview

The WIGGENS WH-01 Miniature Peltier-Cooled Biochemical Incubator is an engineered solution for precise, low-noise, and energy-efficient temperature-controlled environments in life science laboratories. Unlike conventional compressor-based incubators, the WH-01 employs solid-state thermoelectric (Peltier) technology for both heating and cooling—enabling bidirectional thermal control within a compact footprint. This architecture eliminates mechanical vibration, refrigerant emissions, and compressor-related acoustic noise, making it especially suitable for sensitive cell culture workflows, enzyme kinetics studies, and reagent stability testing where microenvironmental integrity is critical. Designed for operation at ambient temperatures up to 20 °C, the unit maintains stable setpoints from +4 °C to +60 °C with high reproducibility and minimal thermal drift. Its air-jacketed stainless steel heating system ensures rapid thermal response and uniform heat distribution, while the forced-air convection system—driven by a continuously adjustable DC fan—enhances intra-chamber homogeneity across the entire 15 L working volume.

Key Features

  • Solid-state Peltier cooling and stainless steel air-jacket heating for zero-emission, low-vibration thermal management
  • TFT touchscreen interface with intuitive PID temperature control algorithm for dynamic stabilization and overshoot suppression
  • Real-time temperature curve logging and adjustable screen brightness for ergonomic operation under varied lighting conditions
  • Programmable thermal profiles: up to 4 independent programs, each supporting 5 user-defined ramp/soak steps with time and temperature parameters
  • Auto-start and auto-stop functions with power-loss recovery logic—ensures experimental continuity after unexpected outages
  • Comprehensive safety architecture: over-temperature cutoff, over-current protection, door-open detection (fan/heater disable + audible alert after 60 s), and thermal runaway prevention
  • Adjustable internal fan speed (0–100%) enables optimization of airflow intensity for delicate samples or low-evaporation protocols
  • Digital temperature display with ±0.1 °C fluctuation and < ±0.6 °C uniformity at 25 °C and 37 °C—validated per ISO 13843 and ASTM E2723 guidelines

Sample Compatibility & Compliance

The WH-01 accommodates standard microbiological and cell culture vessels—including Petri dishes, multiwell plates, test tubes, and small-volume flasks—within its 315 × 200 × 240 mm internal chamber. The stainless steel interior and removable stainless steel shelves support autoclave-compatible cleaning and resist corrosion from common biological buffers and disinfectants. Its design complies with IEC 61010-1:2010 for laboratory equipment safety and meets essential requirements of the EU Machinery Directive 2006/42/EC. While not certified for GMP manufacturing use, the WH-01 supports GLP-aligned workflows through audit-ready features including timestamped alarm logs, programmable temperature history export, and non-volatile memory retention for all settings—even during extended power interruptions. It is routinely deployed in academic research labs, QC/QA departments in pharmaceutical R&D, and clinical diagnostic support units requiring traceable, repeatable incubation conditions.

Software & Data Management

The WH-01 operates autonomously via its embedded firmware without external PC dependency. All operational data—including real-time temperature traces, alarm events (with timestamps and cause codes), and executed program logs—are stored locally in non-volatile memory and accessible directly through the touchscreen interface. Temperature curves can be exported via USB port (optional cable required) in CSV format for post-acquisition analysis in MATLAB, Python, or Excel. Though no proprietary software suite is bundled, the device supports integration into centralized lab monitoring systems via optional RS-485 or analog output modules (sold separately). All firmware updates are delivered as signed binary files through WIGGENS’ secure technical portal, ensuring compliance with FDA 21 CFR Part 11 requirements for electronic records when paired with appropriate validation documentation.

Applications

  • Low-temperature storage and activation of microbial cultures (e.g., E. coli, yeast, lactic acid bacteria)
  • Enzyme activity assays requiring tight thermal regulation between 4 °C and 37 °C
  • Short-term incubation of hybridization reactions, ELISA plate development, and antibody binding steps
  • Stability testing of biologics, vaccines, and diagnostic reagents under controlled thermal stress
  • Supporting cryopreservation workflows—holding thawed samples at 4 °C prior to processing
  • Teaching laboratories where space constraints, noise sensitivity, and energy efficiency are prioritized

FAQ

What is the maximum ambient temperature for optimal WH-01 performance?
The specified temperature range (+4 to +60 °C) assumes an ambient environment of ≤20 °C. Operation above this may reduce cooling capacity and compromise uniformity.
Can the WH-01 be used for CO₂-independent cell culture?
Yes—provided humidity control is managed externally (e.g., via humidified trays or sealed containers), the WH-01 maintains stable temperature for adherent and suspension cultures requiring only thermal regulation.
Is the unit compatible with 24/7 continuous operation?
Yes. Its solid-state thermal architecture and thermal overload protection enable unattended long-term incubation cycles, validated for >10,000 hours MTBF under typical lab conditions.
Does the WH-01 support Fahrenheit temperature display?
No—the interface is configured exclusively for Celsius, consistent with ISO and CLSI reporting standards for biomedical instrumentation.
How is calibration traceability maintained?
The WH-01 includes a factory calibration certificate referencing NIST-traceable reference standards. Users may perform field verification using a calibrated PT100 probe inserted through the optional test port (accessory W6551501).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0