Empowering Scientific Discovery

PMM 1008 Magnetic Field Immunity Test System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PMM
Origin Italy
Manufacturer Type Authorized Distributor
Origin Category Imported
Model PMM 1008
Quotation Upon Request
Compliance IEC 61000-4-8, EN 61000-4-8, EU EMC Directive 2014/30/EU (replacing 89/336/EEC), Low Voltage Directive 2014/35/EU (replacing 73/23/EEC)
Generator Output Continuous up to 160 A / Transient up to 1200 A
Magnetic Field Levels Continuous — Class 1 (1 A/m) to Class 5 (100 A/m), Custom
Open-Circuit Voltage ≤4 V
Coil Dimensions 1035 mm × 1035 mm × 35 mm (square loop)
Antenna Factor 0.87
Inductance ~0.6 µH
DC Resistance 670 µΩ
Height Adjustment Range 0–2000 mm
Weight (Net) 28 kg
Dimensions (W×H×D) 385 × 400 × 215 mm
Power Supply AC 198–264 V, 50/60 Hz
Communication Interface RS-232 / RS-485 (DB9)
Safety Features Thermal cutoff, magnetic overcurrent protection, safety interlock port, fanless design

Overview

The PMM 1008 Magnetic Field Immunity Test System is a fully integrated, standards-compliant solution engineered for precise and repeatable evaluation of electronic equipment’s immunity to low-frequency magnetic fields—specifically in accordance with IEC 61000-4-8 and its harmonized European counterpart EN 61000-4-8. Unlike broadband radiated immunity test systems, this platform employs controlled current-driven square-loop excitation to generate highly uniform, calculable, and traceable magnetic field distributions within defined test volumes. The system operates on the principle of Ampere’s law: a precisely regulated current pulse or continuous waveform is injected into a calibrated square coil (PMM 1008/2), generating a known magnetic field strength (A/m) at the device under test (DUT) location. Its dual-component architecture—comprising the programmable pulse generator (PMM 1008/1) and the isotropic, height-adjustable loop antenna (PMM 1008/2)—ensures full spatial coverage and orientation independence during testing. Designed for laboratory-grade reproducibility and regulatory audit readiness, the PMM 1008 supports both pre-compliance screening and formal compliance verification across industrial control systems, medical electronics, power converters, and railway signaling equipment.

Key Features

  • Real-time current feedback control via built-in current transducer ensures stable magnetic field output despite mains voltage fluctuations or load impedance variations.
  • Isotropic, motor-free mechanical adjustability: the square loop coil (1035 mm × 1035 mm) can be vertically positioned from floor level to 2000 mm and rotated in 3 axes without performance degradation—enabling DUT testing in multiple orientations per IEC 61000-4-8 Annex A.
  • Programmable test sequencing: supports manual, stepwise ramp-up (slow-to-fast), and fully automated timed tests—including continuous exposure (1–12,000 min) and transient pulses (<5 s).
  • Embedded self-calibration routine with user-configurable antenna factor input (default: 0.87), ensuring metrological traceability to national standards laboratories.
  • Acoustic status indication: audible beep confirms active test execution, enhancing operator situational awareness during unattended or multi-station workflows.
  • Fanless thermal management architecture with dual-stage protection: magnetic circuit breaker + temperature-sensing cutoff prevents coil overheating or cable degradation due to prolonged current duty cycles.
  • Low-risk electrical interface: maximum open-circuit output voltage limited to ≤4 V, eliminating risk of electric shock or unintended arcing during setup or maintenance.

Sample Compatibility & Compliance

The PMM 1008 accommodates DUTs of varying form factors—including panel-mounted controllers, embedded modules, PCB assemblies, and rack-mounted instrumentation—within its standardized test volume (defined by ISO/IEC 17025-accredited calibration procedures). The system meets essential requirements of the EU Electromagnetic Compatibility Directive 2014/30/EU and Low Voltage Directive 2014/35/EU, with full documentation supporting conformity assessment under Module A (internal production control). All hardware and firmware are designed to support GLP/GMP-aligned test record integrity: time-stamped test logs, configurable pass/fail thresholds, and non-volatile storage of calibration history. While not intrinsically certified to FDA 21 CFR Part 11, the system’s deterministic behavior, audit-trail-capable RS-232/RS-485 interface, and deterministic timing resolution (±1 s for transients, ±1 min for continuous mode) facilitate integration into validated environments requiring electronic records.

Software & Data Management

The PMM 1008 operates autonomously via front-panel controls but is fully programmable via ASCII command set over RS-232 or RS-485 (DB9). Third-party test automation platforms—including LabVIEW, Python (pySerial), and MATLAB—can initiate, monitor, and log test sequences using standardized SCPI-like syntax. All operational parameters—including field level class selection, dwell time, ramp profile, and interlock status—are queryable in real time. Internal clock synchronization enables timestamped event logging with resolution matching the selected mode (1 s for transients, 1 min for continuous). No proprietary software installation is required; configuration files and test reports are exportable as plain-text CSV or ASCII logs compatible with LIMS and enterprise QA databases. Firmware updates are delivered via serial interface with cryptographic signature verification to maintain integrity.

Applications

  • Immunity validation of PLCs, HMIs, and distributed I/O systems against power-frequency magnetic interference (e.g., near transformers, busbars, or welding equipment).
  • Pre-compliance screening of medical devices per IEC 60601-1-2 Ed. 4.1 (Clause 8.8.3.2), where magnetic field immunity is mandated for life-supporting and critical-care equipment.
  • Testing of smart grid components—including fault indicators, recloser controllers, and substation RTUs—for resilience in high-current utility environments.
  • Verification of automotive ECUs (e.g., battery management systems) exposed to stray fields from high-power inverters or charging circuits.
  • Research-grade characterization of magnetic shielding effectiveness in enclosures, gaskets, and conductive coatings using differential field mapping protocols.

FAQ

Does the PMM 1008 require external calibration traceable to a national metrology institute?
Yes. Annual calibration of both the generator’s current measurement chain and the coil’s antenna factor is recommended per ISO/IEC 17025. PMM provides accredited calibration certificates upon request.
Can the system generate arbitrary waveforms beyond standard 50/60 Hz sinusoids?
No. The PMM 1008 is optimized for power-frequency (50/60 Hz) continuous and damped oscillatory (transient) waveforms per IEC 61000-4-8. It does not support arbitrary waveform generation (AWG) or higher-frequency content.
Is the coil suitable for testing large-format DUTs such as switchgear cabinets?
The 1.035 m square aperture supports DUTs up to ~0.8 m in diagonal dimension. For larger units, sequential positioning or auxiliary coil configurations may be required per Annex B of EN 61000-4-8.
How is safety interlock implemented?
A dedicated 24 V DC safety interlock port accepts externally wired door switches or light curtains. If opened during test execution, the generator immediately terminates current output and enters safe discharge state.
What is the expected service life of the coil under repeated Class 5 (100 A/m) continuous operation?
Under nominal ambient conditions (23 °C, 50% RH) and adherence to thermal duty cycle limits (10 years operational life with no measurable drift in antenna factor or inductance.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0