Empowering Scientific Discovery

PerkinElmer Clarus 500 GC System with Flame Ionization Detector (FID)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin Canada
Model Clarus 500 FID
Product Category Gas Chromatograph
Usage Duration 5–7 years
Warranty 6 months
Configuration Includes FID and autosampler
Condition Refurbished & Fully Tested
Regulatory Compliance Meets ASTM D3606, ISO 10301, and USP <621> for hydrocarbon analysis

Overview

The PerkinElmer Clarus 500 GC System with Flame Ionization Detector (FID) is a high-performance, benchtop gas chromatograph engineered for precision separation and quantitative analysis of volatile and semi-volatile organic compounds. Based on robust capillary column chromatography principles, the Clarus 500 employs temperature-programmed oven control, electronic pressure control (EPC), and a highly stable FID optimized for linear response across six orders of magnitude (10⁶). Designed and originally manufactured in Canada, this system delivers reproducible retention times, low baseline noise (<0.5 pA), and fast thermal equilibration—achieving full oven cooldown from 300 °C to 50 °C in under 4.5 minutes. Its microprocessor-controlled architecture governs all critical parameters including inlet pressure, detector gas flows, and ramp rates, ensuring method transferability and long-term operational stability.

Key Features

  • Integrated 10.4-inch full-color touchscreen interface with intuitive icon-driven navigation—no external PC required for basic operation or method setup
  • Programmable oven with precise ±0.1 °C temperature accuracy over 0–350 °C range and heating/cooling rates up to 125 °C/min
  • FID with auto-ignition, flame monitoring, and optimized jet design for enhanced sensitivity (detection limit ≤ 1.8 pg C/s for n-decane)
  • Electronic Pressure Control (EPC) for carrier gas (He, H₂, N₂) with 0.001 psi resolution and real-time flow calibration
  • Compatible with standard 0.1–0.53 mm ID fused-silica capillary columns; supports split/splitless, on-column, and PTV injection modes
  • Refurbishment includes full optical alignment of FID, replacement of consumables (septa, liners, ferrules), leak-checked gas pathways, and validation against NIST-traceable standards

Sample Compatibility & Compliance

The Clarus 500 FID accommodates a broad spectrum of sample matrices—including petrochemicals, environmental extracts (EPA Method 8015/8260), food volatiles, pharmaceutical solvents (ICH Q3C), and polymer additives—when paired with appropriate column chemistries (e.g., DB-5ms, HP-INNOWAX). All hardware and firmware revisions comply with essential regulatory frameworks: ASTM D3606 for gasoline hydrocarbons, ISO 10301 for benzene/toluene/xylenes in air, and USP for residual solvent testing. The system supports GLP-compliant data acquisition when used with optional Turbochrom software (v7.5+), enabling audit trails, user access levels, and electronic signatures per FDA 21 CFR Part 11 requirements.

Software & Data Management

While standalone operation is fully functional via the onboard GUI, integration with PerkinElmer Turbochrom CDS (Chromatography Data System) enables advanced peak integration, calibration curve generation (linear, quadratic, weighted), and report templating compliant with ISO/IEC 17025 documentation standards. Raw data files (.ch) are stored in vendor-neutral formats compatible with third-party review tools. The refurbished unit includes licensed software media and activation keys; optional upgrades include spectral library search (NIST MS Search), automated method development, and instrument remote monitoring via Ethernet.

Applications

  • Environmental analysis: BTEX quantification in soil/water extracts, VOC profiling in ambient air canisters
  • Petrochemical QA/QC: Hydrocarbon type analysis (HTA) in reformulated gasoline per ASTM D5134
  • Pharmaceutical manufacturing: Residual solvent testing in APIs and excipients (ICH Q3C Class 2/3)
  • Food & flavor chemistry: Headspace analysis of esters, aldehydes, and terpenes in beverages and essential oils
  • Academic research: Reaction monitoring, polymer degradation product identification, and metabolite profiling

FAQ

Is this Clarus 500 GC system fully validated prior to shipment?

Yes—each unit undergoes IQ/OQ protocol execution per ASTM E2500, including temperature uniformity mapping, FID linearity verification, and retention time repeatability testing (RSD < 0.15% over 10 injections). A full validation summary report is provided.
Does the 6-month warranty cover both hardware and software support?

The warranty covers all refurbished components, including detector electronics, oven heater assembly, and EPC modules. Software licensing and remote technical assistance are included for the duration.
Can I upgrade to add an ECD or other detectors post-purchase?

Yes—the Clarus 500 chassis supports dual-detector configurations. ECD, TCD, or NPD modules can be installed onsite by certified field engineers; compatibility with existing firmware is confirmed during pre-delivery configuration review.
What documentation accompanies the system?

You receive the original PerkinElmer user manual (English), refurbishment certificate, calibration records, NIST-traceable test chromatograms, and a signed statement of conformance to ISO 9001:2015 quality management practices.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0