Form Talysurf Intra Economical Profilometer
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Form Talysurf Intra |
| Product Type | Contact Profilometer / Surface Roughness Tester |
| Sensor Type | Inductive |
| Vertical Measurement Range | 1 mm (standard, with 60 mm stylus) / 2 mm (optional, with 120 mm stylus) |
| Vertical Resolution | 16 nm (at 1 mm range), 3.2 nm (at 0.2 mm range) |
| Range-to-Resolution Ratio | 65,536:1 |
| Stylus Force | 0.7–1 mN |
Overview
The Form Talysurf Intra is a compact, cost-optimized contact profilometer engineered by Taylor Hobson — a UK-based leader in precision surface metrology — for reliable roughness and form measurement in both production-floor environments and controlled metrology laboratories. Built upon the proven mechanical architecture of the flagship Form Talysurf S3C platform, the Intra retains identical high-stability drive units and inductive transducer performance while introducing a streamlined, embedded control architecture. Unlike full PC-based systems, the Intra integrates a dedicated PDA-style touchscreen processor that executes real-time acquisition, filtering, and analysis per ISO 4287, ISO 4288, and ASME B46.1 standards — eliminating dependency on external computers and reducing setup complexity. Its design emphasizes operational robustness, intuitive workflow navigation, and rapid deployment without compromising traceable metrological integrity.
Key Features
- Identical mechanical core to Form Talysurf S3C: Same high-rigidity granite base, linear air-bearing stage, and low-noise inductive sensor assembly ensuring consistent repeatability and thermal stability.
- Integrated touchscreen controller: ARM-based PDA processor with resistive touch interface enables direct access to measurement menus, real-time waveform display, and parameter calculation — no external PC required.
- Dual-range vertical capability: Standard 1 mm vertical range (with 60 mm stylus) supports comprehensive roughness + form analysis; optional 2 mm range (120 mm stylus) extends profiling capacity for larger form deviations or stepped surfaces.
- Nanometre-level resolution: 16 nm at full 1 mm range and 3.2 nm at reduced 0.2 mm range, achieved via 16-bit A/D conversion and optimized signal conditioning — delivering high fidelity across diverse surface topographies.
- Low-force stylus system: Adjustable contact force between 0.7 and 1 mN minimizes plastic deformation on soft metals, polymers, and coated substrates while maintaining sufficient signal-to-noise ratio for accurate peak-valley detection.
- Flexible operation modes: Supports wired connection for synchronized control and data transfer, as well as infrared remote operation — ideal for confined fixtures or glove-box integration.
Sample Compatibility & Compliance
The Form Talysurf Intra accommodates a broad spectrum of industrial components, including machined metal parts, injection-molded plastics, ground ceramics, electroplated surfaces, and precision optics substrates. Its modular stylus holder accepts standard 2.5 mm shank diamond tips (e.g., 2 µm radius, 90° included angle), enabling compliance with ISO 3274 stylus geometry requirements. All measurement algorithms adhere to ISO 25178-2 (areal surface texture) and ISO 4287/4288 (profile-based roughness and waviness definitions). The instrument supports GLP-compliant reporting through timestamped, password-protected result exports (CSV, PDF, XML), and its firmware architecture allows audit trail configuration where required under internal quality management systems aligned with ISO/IEC 17025.
Software & Data Management
The embedded operating system runs proprietary Taylor Hobson firmware with preloaded filters (Gaussian, 2RC, phase-corrected), evaluation modules (Rz, Rq, Rsk, Rku, λq, Δa), and profile segmentation tools. Data is stored locally on the PDA’s flash memory and exportable via USB 2.0 or SD card. While not FDA 21 CFR Part 11 certified out-of-the-box (as it lacks electronic signature functionality), the system supports secure user accounts, change logs, and report watermarking — facilitating integration into regulated environments where procedural controls and documentation rigor are mandated. Optional connectivity kits enable networked data logging to centralized MES or LIMS platforms using standard TCP/IP protocols.
Applications
- Production line verification of turned, milled, or ground surfaces against GD&T callouts and surface finish specifications (e.g., Ra ≤ 0.8 µm).
- Wear track depth profiling on bearing races and sliding components.
- Coating thickness validation via step-height measurement on masked substrates.
- Tool wear monitoring through flank face roughness trend analysis.
- Educational use in metrology labs for teaching fundamental concepts of profile filtering, parameter definition, and uncertainty estimation in contact measurement.
- Supplier quality audits requiring portable, ISO-traceable roughness verification without full laboratory infrastructure.
FAQ
Is the Form Talysurf Intra suitable for ISO/IEC 17025-accredited calibration laboratories?
Yes — when operated within documented procedures, with traceable stylus calibration certificates and periodic verification using reference standards (e.g., NIST SRM 1960), it meets the technical competence requirements for routine surface texture assessment.
Can third-party software be used to analyze exported data files?
Yes — raw profile data is saved in ASCII-compatible formats (e.g., .txt with X/Y columns), enabling post-processing in MATLAB, Python (NumPy/Pandas), or commercial metrology software such as MountainsMap or PolyWorks.
What is the typical measurement uncertainty for Ra on a polished steel reference sample?
Under controlled environmental conditions (20 ± 1 °C, <50% RH), with a calibrated 2 µm radius stylus and Gaussian filter (λc = 0.8 mm), expanded uncertainty (k=2) for Ra is typically ≤ ±3.5% of reading for values between 0.02 µm and 5 µm.
Does the Intra support automatic stylus qualification or tip radius verification?
No — stylus qualification must be performed externally using optical interferometry or scanning electron microscopy; however, the system includes built-in diagnostics for sensor linearity and zero-drift monitoring.
Is firmware upgrade support available beyond initial purchase?
Yes — Taylor Hobson provides periodic firmware updates via secure download portal, addressing bug fixes, minor feature enhancements, and compatibility improvements with new stylus configurations or filter standards.