Empowering Scientific Discovery

Jianhu JH-ETC Series Large-Scale Temperature and Humidity Controlled Environmental Test Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jianhu
Origin Shanghai, China
Chamber Type Upright
Cooling Method Air-Cooled
Temperature Range 15–45 °C
Humidity Range 30–98 % RH
Temperature Uniformity ≤ ±2 °C
Temperature Fluctuation ±1 °C (high-temp), ±2 °C (low-temp)
Humidity Uniformity ≤ ±3 % RH
Humidity Fluctuation ±3 % RH
Heating Rate 1.0–3.0 °C/min
Internal Dimensions Custom-engineered per application requirement
Compliance Designed to support validation against ISO 17025, IEC 60068-2, ASTM D4332, USP <1151>, and GB/T 2423 series standards

Overview

The Jianhu JH-ETC Series Large-Scale Temperature and Humidity Controlled Environmental Test Chamber is an engineered platform for long-duration, high-fidelity environmental simulation in reliability engineering and product qualification workflows. It operates on a dual-loop PID-controlled air-circulation architecture with precision-matched heating, refrigeration, and steam-based humidification subsystems. Unlike general-purpose climate chambers, the JH-ETC Series is purpose-built for applications demanding stable thermal-hygrometric profiles across extended operational cycles—particularly where sample volume, spatial uniformity, and regulatory traceability are critical. Its design prioritizes mechanical robustness, thermal inertia management, and repeatable chamber-load response—key attributes required for aging studies, shelf-life validation, and accelerated stress testing in regulated sectors including pharmaceuticals, medical devices, food packaging, and automotive electronics.

Key Features

  • Customizable internal dimensions—engineered to accommodate oversized assemblies, stacked pallets, or multi-unit test configurations without compromising airflow symmetry or sensor placement integrity.
  • Air-cooled refrigeration system with scroll compressor and microchannel heat exchanger, optimized for continuous operation at boundary conditions (e.g., 45 °C / 98 % RH).
  • Dual-sensor humidity control using capacitive RH transducers calibrated traceably to NIST-traceable standards; redundant temperature monitoring via PT100 Class A sensors distributed across top/mid/bottom zones.
  • Integrated thermal insulation with low-conductivity polyurethane foam (≥100 mm thickness) and double-glazed observation window with anti-condensation heating film.
  • Compliance-ready hardware architecture—including non-volatile event logging, real-time parameter archiving, and configurable alarm thresholds aligned with GLP/GMP data integrity expectations.

Sample Compatibility & Compliance

The JH-ETC Series accommodates heterogeneous sample loads—including sealed enclosures, unpackaged PCB assemblies, sterile-packaged biologics, and bulk food commodities—without inducing condensation-induced artifacts or thermal stratification. Chamber interior surfaces are electropolished stainless steel (AISI 304), meeting USP requirements for non-reactivity and cleanability. All control firmware and calibration documentation are structured to support IQ/OQ/PQ execution under ISO/IEC 17025-accredited laboratories. The system supports full audit trail generation per FDA 21 CFR Part 11 requirements when paired with optional validated software modules. Validation packages include as-installed temperature/humidity mapping reports (per ISO 14644-3 Annex B), recovery time assessments, and stability profiles per IEC 60068-3-5.

Software & Data Management

The embedded controller features a 7-inch resistive touchscreen HMI with intuitive navigation, multilingual UI (English, Chinese, Spanish), and real-time graphical display of setpoint vs. actual values across all monitored zones. Data export is supported via USB 2.0 and Ethernet (Modbus TCP/IP), enabling seamless integration into LIMS or MES platforms. Optional PC-based software provides advanced scheduling (multi-step ramp-soak cycles), statistical process monitoring (SPC charts), and automated report generation compliant with ASTM E2911-22 reporting conventions. All logged data include timestamp, operator ID, sensor channel metadata, and digital signature verification—ensuring full ALCOA+ compliance (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available).

Applications

  • Accelerated aging of polymer-based medical device packaging per ISO 11607-1 and ASTM F1980.
  • Stability testing of pharmaceutical intermediates and final dosage forms under ICH Q1A(R3) storage condition protocols (e.g., 30 °C / 65 % RH long-term, 40 °C / 75 % RH accelerated).
  • Environmental stress screening (ESS) of automotive ECUs and ADAS modules per SAE J2245 and GMW14872.
  • Moisture barrier performance evaluation of flexible electronics encapsulants and OLED substrates.
  • Microbial growth inhibition studies for food safety R&D, aligned with ISO 21872-1 and AOAC 990.12 methodologies.

FAQ

Does the JH-ETC Series meet ISO 17025 accreditation requirements for accredited labs?
Yes—the chamber’s metrological configuration, sensor traceability documentation, and uncertainty budgeting framework are designed to satisfy Clause 6.4 and Annex A of ISO/IEC 17025:2017.
Can the system be validated for GxP environments?
Absolutely—qualified installation includes full IQ/OQ documentation, 3-point temperature/humidity mapping, and deviation handling procedures compatible with FDA, EMA, and PMDA audit expectations.
Is remote monitoring and alarm notification supported?
Standard Ethernet connectivity enables SNMP-based alerting and integration with building management systems (BMS); optional cellular gateway adds SMS/email notifications for out-of-spec events.
What maintenance intervals are recommended for sustained accuracy?
Preventive maintenance is scheduled every 12 months, including sensor recalibration, refrigerant pressure verification, humidifier descaling, and fan motor lubrication—all documented per ISO 9001:2015 clause 7.1.5.
Are custom chamber dimensions subject to additional lead time or validation burden?
Custom builds require 8–12 weeks from order confirmation; however, validation support (including pre-commissioning mapping and protocol review) is included without surcharge for projects adhering to Jianhu’s standard engineering interface specifications.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0