Empowering Scientific Discovery

Jianhu JH Series Forced-Air Drying Oven / General-Purpose Laboratory Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jianhu
Origin Shanghai, China
Model JH Series
Type General-Purpose Forced-Air Drying Oven
Temperature Range (Standard) RT + 10 °C to 250 °C
Temperature Range (High-Temp Option) RT + 10 °C to 300 °C
Temperature Resolution 0.1 °C
Temperature Uniformity ±1 °C
Power Input 850 W – 2450 W (model-dependent)
Chamber Volume 30 L – 220 L
Interior Material Mirror-Finish Stainless Steel (AISI 304)
Door Double-Glazed Observation Window with Silicone Rubber Seal
Control System Microprocessor-Based PID Controller with Timer (up to 9999 min), Optional LCD Programmable Controller
Compliance Designed for GLP-compliant environments
Safety Independent Over-Temperature Cut-Off Protection (optional)

Overview

The Jianhu JH Series Forced-Air Drying Oven is a general-purpose laboratory thermal processing instrument engineered for precise, repeatable, and safe operation in research, quality control, and production support applications. It operates on the principle of convection-based heat transfer, utilizing an internally mounted high-temperature centrifugal fan to circulate heated air uniformly throughout the insulated chamber. This forced-air architecture ensures rapid thermal equilibration and minimizes spatial temperature gradients—critical for drying, baking, sterilization, moisture determination, and pre-conditioning of samples across diverse scientific and industrial workflows. Unlike natural-convection ovens, the JH Series maintains consistent thermal profiles even under variable load conditions, making it suitable for both routine and method-critical tasks in regulated environments.

Key Features

  • Mirror-finish AISI 304 stainless steel interior chamber with seamless welded corners and radius-formed edges—resistant to corrosion, easy to decontaminate, and compliant with hygiene-sensitive applications.
  • Microprocessor-controlled PID temperature regulation system with 0.1 °C resolution and ±1 °C uniformity across the working volume; optional programmable LCD controller supports multi-step ramp-soak profiles.
  • Forced-air circulation system featuring a thermally stable, continuously rated fan and optimized duct geometry—ensures airflow velocity and thermal homogeneity meet ISO 17025-relevant performance expectations.
  • Dual-pane observation window with high-temperature silicone rubber gasket provides clear visual monitoring while maintaining thermal integrity and minimizing energy loss.
  • Robust thermal insulation using aluminum silicate fiber between outer casing (powder-coated cold-rolled steel) and inner chamber—reducing surface temperature rise and improving energy efficiency.
  • Independent over-temperature safety cut-off circuit (optional) interrupts power when preset limits are exceeded, fulfilling IEC 61010-1 requirements for laboratory equipment safety.
  • RS485 serial interface (optional) enables integration with LIMS or SCADA systems for audit-trail-capable temperature logging—supporting compliance with FDA 21 CFR Part 11 and EU Annex 11 documentation standards.

Sample Compatibility & Compliance

The JH Series accommodates a broad spectrum of sample types—including glassware, metal components, polymer substrates, pharmaceutical excipients, ceramic precursors, and biological media plates—without risk of cross-contamination or residue accumulation. Its inert stainless-steel chamber and absence of catalytic surfaces prevent unintended chemical reactions during thermal treatment. The oven is routinely deployed in laboratories adhering to ASTM D1654 (corrosion testing), ISO 5725 (accuracy of measurement), USP (sterilization validation), and GMP Annex 15 (qualification of equipment). While not certified as explosion-proof or Class I Div 1, optional configurations may include nitrogen purge ports for oxygen-sensitive processes, aligning with inert-atmosphere drying protocols common in electronics manufacturing and battery material R&D.

Software & Data Management

The standard microcontroller offers time-programmable operation (1–9999 minutes) with audible/visual alarm output upon cycle completion or fault detection. For advanced traceability, the optional RS485-enabled configuration permits bidirectional communication with third-party software platforms (e.g., LabVIEW, MATLAB, or custom Python-based acquisition tools). Logged parameters—including setpoint, actual chamber temperature, elapsed time, and alarm events—are timestamped and exportable in CSV format. When paired with validated software and procedural controls, this functionality satisfies data integrity requirements under ALCOA+ principles (Attributable, Legible, Contemporaneous, Original, Accurate, Complete, Consistent, Enduring, Available) for GLP and GxP-regulated operations.

Applications

  • Drying of filter papers, crucibles, and analytical samples prior to gravimetric analysis (e.g., moisture content per ASTM E1868).
  • Baking of coated wafers, PCBs, and sensor substrates in electronics QA/QC labs.
  • Conditioning of hygroscopic reference standards and calibration artifacts in metrology facilities.
  • Sterilization of non-critical labware and reusable tools where steam autoclaving is impractical.
  • Thermal aging studies of polymers, composites, and adhesives per ISO 188 or ASTM D573.
  • Pre-heating of molds, fixtures, and tooling in small-batch manufacturing environments.
  • Stabilization of reagents and lyophilized powders in pharmaceutical development labs.

FAQ

What is the maximum operating temperature for the standard JH model?
The standard configuration supports up to 250 °C; high-temperature variants (designated “M”) extend the range to 300 °C.
Is the oven suitable for use in a cleanroom environment?
Yes—the mirror-finish stainless steel chamber, absence of particulate-shedding insulation, and smooth internal geometry facilitate ISO Class 5–8 cleanroom compatibility when installed with appropriate HVAC integration.
Can the JH Series be qualified for GMP use?
Yes—when equipped with optional data logging, alarm history, and independent temperature verification ports, it supports IQ/OQ/PQ execution per ASTM E2500 and ISPE GAMP5 guidelines.
Does the unit comply with electrical safety standards for international deployment?
It meets CE marking requirements per EN 61010-1:2010 and is compatible with 220 V / 50 Hz supply; voltage/frequency variants (e.g., 110 V / 60 Hz) are available upon request.
How many shelf positions are adjustable, and what is the maximum load per shelf?
Each chamber includes two adjustable stainless steel shelves; maximum distributed load is 15 kg per shelf, verified per manufacturer’s mechanical stress testing protocol.