Empowering Scientific Discovery

Huake Instrument HK-JYY-80 Automatic Insulating Oil Dielectric Strength Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Huake Instrument
Origin Beijing, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model HK-JYY-80
Pricing Available Upon Request
Measurement Range 0–80 kV
Voltage Measurement Accuracy ≤ ±3%
Resolution 0.1 kV
Electrode Gap 2.5 mm (adjustable)
Rising Rate Options 2 kV/s or 3 kV/s (±10% tolerance)
Stirring Speed 250–300 rpm (magnetic stirring)
Test Repetition 1–6 cycles (user-configurable)
Standby Time 1–10 min (adjustable)
Breakdown Interruption Time ≤10 ms
Temperature Monitoring Range −40.0 to 80.0 °C (±0.5 °C)
Humidity Monitoring Range 0–90.0 %RH (±2 %RH)
Data Storage Capacity 500 test records with date-based retrieval
Communication Interfaces Standard Ethernet (RJ-45), USB
Power Supply AC 220 V ±10%, 50–60 Hz
Power Consumption ≤170 W
Dimensions (L×W×H) 550 × 465 × 410 mm
Weight 35 kg
Electrode Types Disc electrodes (standard per DL/T 429.9), spherical and spherically-capped electrodes (optional per GB/T 507–2002)

Overview

The Huake Instrument HK-JYY-80 Automatic Insulating Oil Dielectric Strength Tester is a precision-engineered instrument designed for the standardized determination of dielectric breakdown voltage in transformer oils, turbine oils, and other insulating liquids used in high-voltage electrical equipment. It operates on the principle of controlled voltage ramping across a defined electrode gap immersed in the test oil sample, detecting the onset of electrical breakdown as a transient current surge. Compliant with key national standards—including GB/T 507–2002 Method for Determination of Dielectric Breakdown Voltage of Insulating Oil and DL/T 429.9–1991 Method for Determination of Dielectric Strength of Insulating Oil—the HK-JYY-80 delivers repeatable, traceable, and auditable results essential for predictive maintenance, commissioning verification, and routine quality assurance in power generation, transmission, and industrial energy infrastructure.

Key Features

  • Intuitive 7-inch capacitive touchscreen interface with embedded real-time status feedback and multilingual menu navigation (English interface standard)
  • Integrated microprocessor-controlled voltage ramp generator with dual selectable rates (2 kV/s or 3 kV/s), calibrated to ±10% accuracy against traceable reference standards
  • Automatic magnetic stirring (250–300 rpm) to ensure homogeneity and eliminate micro-bubbles prior to each test cycle, minimizing measurement variance
  • Comprehensive safety architecture: lid-interlock circuitry ensures immediate power cutoff upon chamber opening; overvoltage/overcurrent protection triggers sub-10 ms disconnection upon breakdown detection
  • Self-diagnostic firmware that monitors HV transformer health, electrode integrity, and environmental sensor drift, logging fault codes for service-level analysis
  • Configurable test protocols—including number of repetitions (1–6), rest time between tests (1–10 min), and post-breakdown dwell period—supporting both ASTM D877/D1816 alignment and internal QA workflows
  • Onboard thermal and humidity sensing (±0.5 °C / ±2 %RH) enables ambient condition correlation with breakdown performance—a critical factor in trending studies and root-cause analysis

Sample Compatibility & Compliance

The HK-JYY-80 accommodates standard IEC 60156-compliant test cells and supports three electrode geometries to meet divergent regulatory and application requirements: disc electrodes (per DL/T 429.9, 25 mm diameter, 2.5 mm gap), spherical electrodes (per GB/T 507–2002), and spherically-capped electrodes (also per GB/T 507). Each configuration is mechanically adjustable and verified using certified gauge blocks. The system is engineered for use with mineral-based, synthetic ester, and silicone insulating oils meeting IEC 60296, ASTM D3487, or IEEE C57.106 specifications. All operational parameters—including voltage ramp linearity, timing resolution, and data timestamping—are validated per ISO/IEC 17025 calibration guidelines. The device supports GLP-compliant audit trails when integrated into LIMS environments via Ethernet or RS-232, and satisfies basic requirements for FDA 21 CFR Part 11 electronic record integrity when paired with appropriate user access controls and digital signature protocols.

Software & Data Management

Data acquisition and reporting are managed through an embedded Linux-based firmware platform supporting dual-mode output: local thermal printing (auto/manual selection) and structured digital export. Test records—including breakdown voltage, ambient temperature/humidity, electrode type, stir duration, and pass/fail status—are stored with ISO 8601 timestamps in non-volatile memory (500-entry capacity). Retrieval is date-ordered and searchable by operator ID or batch identifier. Via the standard RJ-45 Ethernet port, the instrument exposes a RESTful API endpoint compatible with common LIMS platforms (e.g., Thermo Fisher SampleManager, LabVantage) for automated ingestion of raw values, metadata, and QC flags. USB host mode permits firmware updates and CSV-formatted report exports to external storage. No proprietary desktop software is required; configuration and diagnostics are fully accessible through the onboard UI or remote HTTP interface.

Applications

  • Routine dielectric strength screening of transformer oil during substation maintenance outages
  • Commissioning verification of insulating fluid integrity prior to energization of new switchgear or power transformers
  • Root-cause investigation of repeated insulation failures in rotating machinery lubricants
  • Quality control testing at oil reclamation facilities processing reclaimed mineral oils
  • Research-grade evaluation of aging behavior in alternative bio-based insulating fluids under accelerated thermal stress
  • Third-party laboratory accreditation testing under CNAS or A2LA scopes requiring documented traceability to national metrology institutes

FAQ

What standards does the HK-JYY-80 comply with?
It conforms to GB/T 507–2002 and DL/T 429.9–1991, and its electrode configurations align with IEC 60156 and ASTM D877 test methodologies.
Can the instrument be integrated into an existing LIMS environment?
Yes—via standard Ethernet (RJ-45) or optional RS-232, using HTTP-based data exchange or Modbus RTU protocol.
Is calibration traceable to national standards?
Voltage output and timing circuits are factory-calibrated against NIM (National Institute of Metrology, China)-certified references; full calibration certificates are provided with each unit.
How is operator safety ensured during high-voltage operation?
The system implements redundant hardware interlocks: mechanical lid switch, real-time current monitoring, and automatic arc-quenching within 10 ms of breakdown detection.
What environmental conditions are required for valid measurements?
Ambient temperature must be maintained between 10–40 °C (dry, dust-free); relative humidity ≤80%; and electromagnetic interference must remain below levels specified in IEC 61000-4-3 for Class B equipment.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0