Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-218 (New Generation)
TypeBenchtop Laboratory Analyzer
Measurement Range0–200 μg/L or 0–2000 μg/L
Resolution0.1 μg/L
Accuracy±2% FS
Repeatability≤1%
Stability±1% FS / 4 h
Display192 × 64 dot-matrix LCD (Chinese/English switchable)
Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions392 × 260 × 100 mm (L × W × H)
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
ModelHK-358AO
TypeOnline Sodium Ion Monitor
Measurement Range(1.00–8.00) pNa, 0.23 μg/L–2.30 g/L, (0.00–14.00) pH
Detection Limit0.01 pNa, 0.01 μg/L, 0.01 pH
Response Time≤2 min at 25 °C
Temperature Range(0.0–99.9) °C
Temperature Accuracy±0.5 °C
Resolution0.01 pNa / 0.01 μg/L / 0.01 pH
Channels1–4 configurable
OutputFour isolated (0–10) mA / (0–20) mA / (4–20) mA current outputs
CommunicationRS-485 or Profibus-DP optional
Dimensions451 mm × 684 mm × 230 mm (W×H×D)
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-358 Steam
TypeOnline Sodium Ion Analyzer
Measurement Range(1.00–8.00) pNa, 0.23 µg/L – 2300 mg/L
Detection Limit0.01 pNa or 0.01 µg/L
Response Time (T90)2 min at 25 °C
Accuracy±0.05 pNa or ±5 µg/L (whichever is greater, within ±10 °C of calibration temperature)
Temperature Range(0.00–99.9) °C
Temperature CompensationAutomatic or Manual (0.1–60.0 °C)
OutputDual isolated 4–20 mA (or 0–10/0–20 mA), dual programmable alarm relays
Display192 × 64 dot-matrix LCD (English/Chinese selectable)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
Dimensions450 mm × 690 mm × 190 mm (W × H × D)
Weight20 kg
EnclosureAluminum chassis, panel-mount design
ComplianceDesigned for continuous steam-phase sodium monitoring in high-purity water/steam cycles per IAPWS guidelines and power plant QA/QC protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-5801N120
Purified Water GradeType I (ASTM D1193-20)
Resistivity18.2 MΩ·cm @ 25°C
Heavy Metals & Soluble Silica< 0.5 ppb
Total Organic Carbon (TOC)< 10 ppb
Microbial Count< 0.05 EU/mL
Particles (>0.1 µm)< 2 particles/mL
RO Recovery Rate>30%
RO Output Capacity≥120 L/h @ 25°C
Feed Water RequirementMunicipal tap water, TDS < 200 ppm, pressure 0.1–0.4 MPa, temp. 5–45°C
Integrated Storage6-gallon pressurized tank (optional 11-gallon external tank)
UV SterilizationBuilt-in 185/254 nm dual-wavelength lamp
Conductivity MonitoringReal-time online measurement with temperature compensation
Power SupplyAC 100–120 V or 200–240 V, 50/60 Hz
Rated Power240 W
Dimensions (L×W×H)630 × 556 × 611 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-3150ZL
Measurement Range0–100 mN/m
Accuracy≤ ±0.3 mN/m
Sensitivity0.1 mN/m
Temperature Measurement Range0–50.0 °C
Temperature Accuracy±0.5 °C
Motor Descent Speed0.3–0.4 mm/s
Data Storage Capacity500 test records
Power Supply85–264 VAC, 50/60 Hz
Power Consumption≤50 W
Dimensions (L×W×H)190 × 300 × 435 mm
Weight7.5 kg
InterfaceRJ45, USB
Operating Environment10–40 °C, RH ≤85%, non-corrosive, low-vibration, low-EMI environment
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-51
Instrument CategorySodium Ion Analyzer
Form FactorBenchtop
Measurement Range(1.00–8.00) pNa, 0.23 μg/L – 2.30 g/L
Detection Limit0.01 pNa, 0.01 μg/L
Response Time (T90)2 min at 25 °C
Accuracy±0.03 pNa or ±5 μg/L (whichever is greater)
Temperature Range(0.00–99.9) °C
Display192 × 64 dot-matrix LCD (English/Chinese selectable)
Resolution0.01 pNa, 0.01 μg/L
Input Impedance≥1 × 10¹² Ω
Temperature SensorPt1000
Temp. CompensationAutomatic or Manual (0.1–60.0 °C)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption3 W
Dimensions270 × 200 × 65 mm (L × W × H)
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-5200
QuotationUpon Request
Cooling Capacity4.5 kW
Refrigeration Power5 HP
Electrical Power Input6 kW
Circulating Pump Power1.5 kW
Max. Sample Inlet Temp≤40 °C
Outlet Temp Control(25 ±1) °C
Total Sample Flow Rate1500 mL/min
Sample Points1–20
Cooling Water RequirementP ≤ 0.2 MPa, Q ≤ 6 t/h
Circulation Flow Rate12 L/h
Temperature Stabilization Time≤3 min for 0.35 ton coolant
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-3140WSA
Measurement PrincipleCoulometric Karl Fischer Titration
Detection Range1 μg – 200 mg H₂O
Resolution0.1 μg
Accuracy±2 μg (3–1000 μg), ±0.3% RSD (>1 mg H₂O)
Electrolysis Current0–400 mA
Electrolysis Rate2.2 mg/min (37 μg/s)
Display800×480 Color TFT Touchscreen (Bilingual: English/Chinese)
Data Storage500 Time-Stamped Records
ConnectivityUSB 2.0, RJ-45 Ethernet (LIMS-Compatible), RS-232 (Printer Optional)
Power Supply100–240 VAC, 50/60 Hz
Dimensions400 × 260 × 240 mm (L×W×H)
Weight~2 kg
ComplianceDesigned for ASTM D6304, ISO 12937, USP <921>, and GLP/GMP-aligned laboratory workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-208
PriceUpon Request
Display192 × 64 dot-matrix LCD (Chinese/English selectable)
Measurement Range0–20 mg/L or 0–50 mg/L
Resolution0.01 mg/L
Basic Error±2% FS
Repeatability≤1%
Stability±1% FS / 4 h
Ambient Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions (L×W×H)392 × 260 × 100 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-268
PricingAvailable Upon Request
Measurement RangeNaOH: (0–5.00) wt%
H₂SO₄(0–5.00) wt%
HCl(0–10.00) wt%
NaCl(0–5.00) wt% or (0–10.00) wt% (custom ranges available upon request)
Accuracy±1.5% of Full Scale (F.S.)
Measured MediaAqueous solutions of HCl, NaOH, H₂SO₄, NaCl (specified at order)
Temperature Compensation Range0–55 °C
Display4-digit, 0.8-inch LED
Power Supply220 V AC via external power adapter (~5 W)
Dimensions (L×W×H)350×230×120 mm
Weight1.5 kg
Sensor ProbeØ39×100 mm
cable length1 m
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginDomestic (China)
ModelHK-108W
Price RangeUSD 14,000 – 42,000 (FOB)
Instrument TypeOnline Continuous Analyzer
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-3C
Instrument TypeBenchtop
Parameter TypeSingle-parameter (pH)
Measurement Range0.00–14.00 pH
Resolution0.01 pH
Accuracy±0.02 pH
Calibration SolutionsGB/T 604–2002 compliant standard buffers (pH 4.00, 6.86, 9.18 at 25 °C)
Temperature CompensationAutomatic or manual (0.1–60.0 °C)
Input Impedance≥1 × 10¹² Ω
Response Time (T₉₀)≤60 s at 25 °C
Display192 × 64 dot-matrix LCD (switchable Chinese/English)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption3 W
Dimensions270 × 200 × 65 mm (L × W × H)
Weight1.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-288
Price RangeUSD 4,200 – 7,000 (FOB)
Instrument TypeLaboratory Turbidimeter
Measured ParameterTurbidity
Operating SystemWindows CE
Display7-inch TFT LCD Touchscreen
Light SourceHigh-Stability Infrared LED (850 nm)
Measurement PrincipleNephelometric Detection (90° Scattered Light) with Chromatic Compensation
Range0–1000 NTU
Resolution0.01 NTU
Accuracy±5% of reading
Repeatability±1% RSD
Drift≤±1.5% FS / 30 min
UnitsNTU, FTU, mg/L (as SiO₂)
Data Storage100,000 records (measurements, calibrations, system logs)
InterfaceUSB 2.0
Calibration Options1-, 2-, or multi-point (up to 5 points)
ComplianceCMC Certified (China Metrology Certification, Certificate No. CMCC2023-XXXXX)
Environmental Operating Conditions5–45 °C ambient
Power SupplyAC 85–265 V, 45–65 Hz
Power Consumption10 W
Dimensions (L×W×H)390 × 248 × 175 mm
Weight4.2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-7000
PricingAvailable Upon Request
Control Channels2 / 4 / 6 / 8 channels
Operating Temperature0–70 °C
Relative Humidity≤93% RH (non-condensing)
Input Signal4–20 mA (calibratable within 2–30 mA)
Display Range0–9999 (numeric), or time format (YYYY-MM-DD HH:MM:SS)
Analog Bar Graph0–100% FS
Communication InterfaceRS-485 digital output
Alarm Relay OutputSPST dry contact, rated AC 220 V / 3 A or DC 24 V / 3 A
Alarm FunctionalityDual-stage audible/visual alarm with time-stamped event lockout
Data RetentionNon-volatile memory for operational history (power-on/off, alarm, fault, reset, calibration)
Local CalibrationSupported for connected transmitters
ComplianceGB 16808–1997
Measurement Accuracy±1% FS
Display Resolution1 digit
Alarm Setpoint Range0–9999 (user-configurable)
Display ModeDual-channel — numeric LED + analog bar graph
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-328
Display192 × 64 dot-matrix LCD (Chinese/English selectable)
pH Range0.00–14.00 pH
ORP Range−1000 to +1000 mV
Temperature Range0.00–99.9 °C
ATC Range0.1–60.0 °C
pH Resolution0.01 pH
mV Resolution0.1 mV
Temp. Resolution0.1 °C
pH Accuracy±0.05 pH
Temp. Accuracy±0.5 °C
Response Time (T90)90 s at 25 °C
OutputDual isolated 4–20 mA (or 0–10 mA / 0–20 mA), configurable for pH or temperature
Max. Load800 Ω @ 20 mA
Alarm Outputs2 programmable relay outputs
CommunicationRS-485, Profibus DP, HART
Sample Temp.5–50 °C
Sample Flow Rate6 L/h
Max. Suspended Solids≤5 µm (no colloids or oils)
Ambient Temp.5–45 °C
Humidity≤90% RH (non-condensing)
Storage Temp.−20 to +55 °C (electrode stored separately >0 °C)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption≤8 W
Dimensions146 × 146 × 154 mm (W×H×D)
Panel Cutout139 × 139 mm
Weight2 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-5300
Configuration OptionsSingle-Pump-Single-Tank, Dual-Pump-Single-Tank, Triple-Pump-Dual-Tank, Quad-Pump-Dual-Tank
Solution Tank Capacity0.5–1.5 m³
Dosing Pump Power Options0.37 / 0.55 / 0.75 / 1.5 kW
Max Dosing Flow Rate160 L/h
Max Discharge Pressure16.0 MPa
Control ModesAutomatic (PID + Fuzzy Logic), Manual, Soft-Manual
Safety FeaturesLow-Low Level Pump Shutdown, Pressure Relief Valve, Phase Loss & Overcurrent Protection
Output Signal4–20 mA Level Feedback
ComplianceDesigned for IEC 61508 SIL 2-capable integration, compatible with DCS/SCADA systems per IEC 62443 cybersecurity guidelines
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (PRC)
ModelHK-7200A
PriceUpon Request
Detection PrincipleMetal Oxide Semiconductor (MOS)
DisplayOLED, Bilingual (Chinese/English)
Operating Temperature-40 °C to +70 °C
Atmospheric Pressure Range86–106 kPa
Measurement Range Options0–100 ppm, 0–200 ppm, 0–500 ppm, 0–1000 ppm, 0–2000 ppm
Resolution1 ppm
Accuracy±5% FS
Response Time (T90)≤30 s
Alarm OutputDual-level visual (LED) and relay
Signal Outputs4–20 mA, CAN bus, RS485
Transmission Distance4–20 mA ≤1000 m (2.5 mm² cable), CAN ≤10 km, RS485 ≤1.2 km
Power SupplyDC 18–30 V
Wiring3-wire or 4-wire configuration
Power Consumption≤2 W
Explosion ProtectionEx d IIC T6 Gb
Ingress ProtectionIP66
Compliance StandardGB 12358–2006
Sampling MethodNatural diffusion
Sensor InterfaceHot-swappable, plug-and-play MOS sensor module
Firmware Architecture32-bit embedded microcontroller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake
ModelHK-3061DZ
Power Supply(198–264) VAC, 50/60 Hz
Test VoltageDC 500 V
Resistivity Range1×10⁸ – 1×10¹⁶ Ω·cm
Repeatability≤15%
Reproducibility≤25%
Temperature Control RangeLow-temp bath (10–30) °C
Temperature Accuracy±0.2 °C
Electrode Cells4 (3 high-temp, 1 low-temp)
Data Storage500 test records with date-based retrieval
InterfaceUSB (standard), RJ-45 Ethernet (standard), RS-232 (optional)
Dimensions400 × 320 × 240 mm (L×W×H)
Weight15 kg
Operating Environment10–35 °C, ≤70% RH, non-corrosive, low EMI/EMF
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-3040YN
Price RangeUSD 1,400 – 4,200
Temperature Control RangeAmbient to 100 °C
Temperature Stability±0.1 °C
Bath ConfigurationDual-layer cylindrical stainless-steel bath
Number of Test Positions4
Stirring Speed1250 rpm
Heating PowerMain heater 800 W + Auxiliary heater 300 W
Capillary Mounting Capacity2 capillaries simultaneously
Capillary Sizes Supplied0.8 mm, 1.0 mm, 1.2 mm, and 1.5 mm nominal bore
Data StorageUp to 1000 test records with date/time stamping
Interface OptionsEthernet and USB 2.0
DisplayColor LCD touchscreen with bilingual (Chinese/English) UI
Built-in Thermal PrinterYes, auto/manual print mode
Power SupplyAC 198–242 V, 50–60 Hz or AC 120 V ±10%, 60 Hz ±1 Hz (configurable at order)
Dimensions (W×D×H)400 × 450 × 650 mm
Net Weight25 kg
Operating Environment0–40 °C, RH ≤85%, non-corrosive, low-vibration, EMI/EMF-shielded ambient
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelHK-3040YN
Price RangeUSD 1,400 – 4,200
Temperature Control RangeAmbient to 100 °C
Bath Uniformity±0.1 °C
Temperature Resolution0.01 °C
Stirring Speed1250 rpm
Heating PowerMain 800 W + Auxiliary 300 W
Capillary Mounting Positions4
Sample Trials per Run1–6
Data Storage Capacity1000 test records
DisplayColor LCD touchscreen (Chinese/English UI)
ConnectivityStandard USB + RJ-45 Ethernet (optional RS-232)
Dimensions (L×W×H)400 × 450 × 650 mm
Weight25 kg
ComplianceGB/T 265–1988 (equivalent to ASTM D445 & ISO 3104)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-518
Price RangeUSD 1,400 – 4,200 (FOB)
Instrument TypeBenchtop Water Quality Analyzer
AnalyteCu²⁺ (Copper Ions)
Display192 × 64 Dot-Matrix LCD (Chinese/English Switchable)
Measurement Range0–200 µg/L
Resolution0.1 µg/L
Accuracy±2% FS
Repeatability≤1% RSD
Stability±2% FS / 4 h
Operating Temperature5–45 °C
Relative Humidity≤90% RH (non-condensing)
Power SupplyAC 100–240 V, 50–60 Hz
Power Consumption40 W
Dimensions (L×W×H)392 × 260 × 100 mm
Weight5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuake Instrument
OriginBeijing, China
ModelHK-1309pH
Measurement PrincipleConductivity-based pH calculation (VGB-R 450L compliant)
pH Range7.5–11.5
Cation Conductivity Range0.000–200.0 µS/cm (with selectable cell constants: 0.01, 0.1, 1.0 cm⁻¹)
Resolution0.001–0.1 µS/cm (dependent on range)
Ammonia Range0.01–10 ppm
Temperature CompensationLinear, neutral salt, ammonia water, strong acid modes
ComplianceHK-338 Enterprise Standard, JJG 376–2007 Verification Regulation for Conductivity Meters
System IntegrationIntegrated stainless-steel panel with flow cell, cation exchange column, regeneration unit, solenoid valves, and dual-conductivity sensors
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuakeyi
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelHK-3140WSA
Pricing RangeUSD 7,000–14,000 (FOB)
Titration MethodFully Automatic Coulometric Titration
Instrument TypeCoulometric Karl Fischer Moisture Analyzer
Water Content Measurement Range1 µg – 200 mg H₂O
Resolution0.1 µg
Accuracy±2 µg for 3–1000 µg H₂O
Minimum Dispensed Volume1 µL (via syringe)
Electrolytic Current Output0–400 mA
Electrolysis Rate2.2 mg/min (37 µg/s)
Power Consumption50 W
Operating Voltage100–240 VAC, 50/60 Hz
Dimensions400 × 260 × 240 mm (L×W×H)
Weight2.0 kg
Data Storage500 timestamped records with searchable filters (date range, sample ID)
ConnectivityStandard USB 2.0, RJ-45 Ethernet port
Display800×480 color TFT-LCD touchscreen with bilingual (English/Chinese) UI
Stirring Speed5 adjustable levels
Safety & DiagnosticsReal-time electrode open/short circuit detection, blank current auto-compensation, endpoint drift correction, overcurrent/overheat protection
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeAuthorized Distributor
Origin CategoryDomestic (China)
ModelHK-3130KQ
PricingAvailable Upon Request
Temperature Control RangeAmbient to 100 °C
Water Bath Temperature Accuracy±0.3 °C
Air Temperature Accuracy±3 °C
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption≤800 W
Gas Pressure0.2 kgf/cm² (≈19.6 kPa)
Operating Ambient Temperature5–40 °C
Operating Ambient Humidity≤85% RH
Dimensions (W×D×H)480 × 320 × 520 mm