Empowering Scientific Discovery

LabCompanion P-Series Temperature and Humidity Environmental Test Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand LabCompanion
Origin Guangdong, China
Manufacturer Type Direct Manufacturer
Product Category Domestic
Model P-Series
Pricing Upon Request
Internal Dimensions (mm) HP-100: 400×500×500
HP-225 500×600×750
HP-500 700×800×900
HP-010 1000×1000×1000
Temperature Range RT+10 °C to 100 °C
Humidity Range 45–98 %RH
Temperature Uniformity ≤2 °C
Temperature Fluctuation ±0.5 °C
Humidity Deviation ±2 %RH
Control System PID-based digital temperature & humidity controller
Construction SUS304 stainless steel inner chamber, A3 steel outer cabinet with powder coating
Insulation High-density ultra-fine glass wool
Air Circulation Single-loop forced convection with low-noise motor
Power Supply 380 V, 3-phase 4-wire
Compliance Designed per GB/T 10586–2014 (formerly GB10586-89) “Technical Requirements for Damp Heat Test Chambers”

Overview

The LabCompanion P-Series Temperature and Humidity Environmental Test Chamber is an engineered solution for accelerated environmental stress testing of electronic components, automotive parts, packaging materials, and industrial polymers under controlled cyclic or steady-state thermal and hygrothermal conditions. Based on the fundamental principles of convective heat transfer and vapor diffusion equilibrium, the chamber maintains precise, repeatable profiles across wide operational ranges—enabling evaluation of condensation susceptibility, material swelling, insulation degradation, solder joint fatigue, and long-term reliability under combined thermal and moisture loading. Its design adheres strictly to GB/T 10586–2014, aligning with internationally recognized test methodologies referenced in IEC 60068-2-30 (damp heat, cyclic), MIL-STD-810H Method 507.6, and JIS C 0021, ensuring compatibility with cross-industry qualification protocols.

Key Features

  • Stainless steel inner chamber (SUS304 mirror finish) and robust A3 steel outer enclosure with electrostatic powder coating for corrosion resistance and structural integrity.
  • PID-controlled digital microprocessor system with independent temperature and humidity setpoint programming, enabling both constant and programmable ramp-hold profiles.
  • Shallow-water reservoir humidification system coupled with stainless steel finned-tube electric heaters for rapid, stable RH response without water droplet carryover.
  • Double-glazed observation window with integrated LED lighting ensures continuous visual monitoring while minimizing thermal leakage.
  • Low-noise axial fan-driven single-loop air circulation system optimized for uniform airflow distribution—validated by internal mapping per ISO 16750-4 Annex B.
  • Dedicated 50 mm diameter test port (left-side, sealed with silicone gasket) facilitates real-time signal feedthrough for external instrumentation or sensor integration.
  • Multi-layer safety architecture: independent over-temperature cut-off, dry-run protection for humidifier, phase-loss detection, and pressure-relief venting.

Sample Compatibility & Compliance

The P-Series accommodates a broad spectrum of sample geometries—from PCB assemblies and lithium-ion battery modules to medical device housings and polymer films—within its standardized internal volumes (100 L to 1000 L). All models meet the mechanical and metrological requirements of GB/T 10586–2014 for damp heat chambers, including spatial uniformity verification, stability tolerance validation, and humidity generation accuracy assessment. The chamber’s thermal inertia and humidity recovery time are characterized per IEC 60068-3-5, supporting traceable test execution under GLP-compliant laboratory environments. Optional calibration certificates (NIST-traceable sensors) and IQ/OQ documentation packages are available to support FDA 21 CFR Part 11–aligned validation workflows.

Software & Data Management

While the standard configuration features a front-panel PID controller with local data logging (up to 100 hours), optional RS485/Modbus RTU or Ethernet interfaces enable seamless integration with SCADA systems or centralized LIMS platforms. Third-party software (e.g., LabVIEW, MATLAB, or custom Python-based acquisition tools) can poll real-time temperature/humidity values, alarm states, and setpoint history via ASCII protocol. For audit-ready reporting, optional chart recorders or thermal printers output time-stamped curves with 4–20 mA analog outputs for legacy PLC interfacing. All logged data retains timestamping, operator ID (if network-authenticated), and event-tagged anomaly markers—supporting ALCOA+ data integrity principles.

Applications

  • Electrical & electronics: Evaluation of conformal coating adhesion, connector oxidation, and capacitor ESR drift under prolonged 85 °C/85 %RH exposure (JEDEC JESD22-A101).
  • Automotive: Validation of infotainment displays, ADAS sensor housings, and wiring harness insulation per ISO 16750-4 and LV-124.
  • Pharmaceutical packaging: Accelerated stability testing of blister packs and cold-chain secondary packaging under ICH Q1A(R2) guidelines.
  • Materials science: Quantification of hygroscopic expansion in composites, hydrolysis kinetics in polyesters, and moisture diffusion coefficients via gravimetric analysis.
  • Quality assurance: Routine incoming inspection of raw materials (e.g., adhesives, resins) prior to high-value assembly processes.

FAQ

What standards does the P-Series chamber comply with?
It is designed and verified per GB/T 10586–2014 and supports test execution aligned with IEC 60068-2-30, MIL-STD-810H Method 507.6, and ISO 16750-4.
Can the chamber perform temperature-only or humidity-only cycles?
Yes—the control system allows independent activation of heating, cooling (via optional chiller interface), and humidification subsystems to configure non-coupled profiles.
Is third-party calibration and validation support available?
Yes, accredited calibration services (including uncertainty budgets per ISO/IEC 17025) and full IQ/OQ documentation are offered as configurable options.
What is the typical humidity recovery time after door opening?
For the HP-500 model at 85 °C/85 %RH, recovery to ±2 %RH tolerance typically requires ≤12 minutes, verified per IEC 60068-3-5 Clause 6.2.
Does the system support remote monitoring via Ethernet or cloud platforms?
Standard Modbus RTU over RS485 is included; optional Ethernet/WiFi gateways enable MQTT or HTTP API connectivity for integration into Industry 4.0 infrastructure.