Jinteng GM-0.5A Dual-Mode Oil-Free Diaphragm Vacuum Pump
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GM-0.5A |
| Instrument Type | Diaphragm Pump |
| Product Type | Oil-Free Vacuum Pump |
| Pumping Speed | 30 L/min |
| Ultimate Vacuum Pressure | 200 mbar (abs) |
| Motor Power | 160 W |
| Operating Temperature Range | 7–40 °C |
| Max. Surface Temperature | <60 °C |
| Noise Level | <55 dB(A) |
| Inlet/Outlet Port Diameter | Ø6 mm |
| Dimensions (W×D×H) | 210 × 160 × 235 mm |
| Net Weight | 8 kg |
| Dual-Mode Operation | Vacuum & Pressure (±) |
Overview
The Jinteng GM-0.5A Dual-Mode Oil-Free Diaphragm Vacuum Pump is an engineered solution for laboratories requiring reliable, contamination-free vacuum and positive pressure generation without lubricating oil. Based on positive displacement via elastomeric diaphragm oscillation, the pump operates on a dry-running principle—eliminating hydrocarbon vapor backstreaming, oil mist carryover, or maintenance associated with rotary vane or piston systems. Its dual-mode architecture enables seamless switching between vacuum aspiration (e.g., filtration, degassing, solvent evaporation) and low-pressure air delivery (e.g., sample purging, membrane pressurization, pneumatic actuation), all within a single compact unit. Designed for integration with analytical instrumentation—including HPLC sample prep stations, SPE manifolds, lyophilizers, and benchtop gas chromatography auxiliary modules—the GM-0.5A meets core operational demands of QC/QA labs, pharmaceutical R&D facilities, forensic analysis units, and food safety testing environments where regulatory traceability and chemical compatibility are essential.
Key Features
- Oil-free operation ensures zero hydrocarbon contamination—critical for GC-MS sample introduction, sterile filtration, and USP compliant aseptic processing.
- Dual-mode functionality supports both vacuum (down to 200 mbar abs) and positive pressure (up to 0.08 MPa gauge) from one motor-driven mechanism, reducing equipment footprint and cross-contamination risk.
- Aluminum alloy housing provides structural rigidity, thermal dissipation efficiency, and corrosion resistance against common organic solvents and aqueous media encountered in fine chemical and biopharmaceutical workflows.
- Imported nitrile rubber diaphragm delivers high fatigue resistance (>10,000 hours MTBF under continuous duty), minimal hysteresis, and inertness toward acids, bases, and alcohols.
- Passive self-cooling airflow path integrated into chassis design enables uninterrupted 24/7 operation without external cooling or duty-cycle limitations.
- Adjustable pressure regulation via integrated needle valve allows precise control over suction force—enabling optimization for delicate membrane filtration (e.g., 0.22 µm PVDF filters) or rapid bulk liquid removal.
- Low-noise (<55 dB[A]) brushless motor with imported precision bearings minimizes acoustic interference in shared lab spaces and supports GLP-compliant documentation of ambient conditions.
Sample Compatibility & Compliance
The GM-0.5A is compatible with standard laboratory glassware (e.g., Büchner funnels, filter flasks, desiccators) and modular vacuum manifolds equipped with Ø6 mm barbed fittings. Its chemically resistant wetted path—comprising fluorocarbon gaskets, stainless steel valve plates, and elastomeric diaphragms—meets ISO 8573-1 Class 4 purity requirements for non-lubricated compressed air. While not certified to IEC 61000-6-3 or UL 61010-1 out-of-box, the pump conforms to general electrical safety principles applicable to Class II laboratory equipment operating within ambient temperature ranges of 7–40 °C and relative humidity ≤80% non-condensing. It supports method validation under ASTM D2879 (vacuum distillation), ISO 11348 (luminescent bioassay preparation), and pharmacopeial procedures requiring defined vacuum stability per USP Analytical Instrument Qualification.
Software & Data Management
As a standalone analog-operated device, the GM-0.5A does not incorporate embedded firmware, digital displays, or data logging capabilities. Its operational parameters—including inlet pressure, flow rate, and motor load—are monitored externally using calibrated gauges, flow meters, or process sensors installed downstream in the vacuum line. For audit-ready environments governed by FDA 21 CFR Part 11 or EU Annex 11, users may integrate the pump into validated systems via external PLC-controlled solenoid valves and pressure transducers, enabling electronic record capture of runtime, pressure setpoints, and fault events through third-party SCADA platforms.
Applications
- Routine vacuum filtration of biological suspensions, nanoparticle dispersions, and protein solutions using cellulose acetate or PTFE membranes.
- Solid-phase extraction (SPE) cartridge conditioning and elution across environmental water testing (EPA Method 525.3) and clinical toxicology workflows.
- Desiccation of hygroscopic standards prior to gravimetric calibration or Karl Fischer titration.
- Positive-pressure drying of microfluidic chips and MEMS devices following wet etching processes.
- Gas purging of headspace vials in volatile organic compound (VOC) analysis prior to GC injection.
- Supporting vacuum-assisted tissue homogenization and DNA extraction kits in molecular diagnostics labs.
FAQ
Is the GM-0.5A suitable for use with aggressive solvents such as chloroform or THF?
Yes—its diaphragm and internal seals are formulated for intermittent exposure to halogenated and polar aprotic solvents; however, prolonged continuous contact is not recommended without inline cold traps or chemical scrubbers.
Can this pump achieve high vacuum levels required for mass spectrometry applications?
No—the ultimate vacuum of 200 mbar (abs) limits its use to rough vacuum applications; it is not intended as a backing pump for turbomolecular or diffusion pumps.
Does the pump require periodic maintenance or consumable replacement?
Only the inlet particulate filter (included) should be inspected and replaced every 6 months under normal lab use; the diaphragm and valves are designed for >10,000 hours of service life without scheduled intervention.
What electrical safety certifications does the GM-0.5A hold?
It complies with GB 4793.1–2007 (Chinese equivalent of IEC 61010-1) for laboratory electrical equipment; CE marking is available upon request for export configurations.
Is there a version with digital pressure feedback or RS-485 communication?
Not currently—the GM-0.5A is an analog-only platform; Jinteng offers the GM-D series for digitally controlled variants with Modbus RTU interface and real-time pressure telemetry.