Empowering Scientific Discovery

CP Lab Safety EF-4-30020-SYS 4″ ECO Waste Collection Funnel System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CP Lab Safety
Origin USA
Manufacturer Type Authorized Distributor
Product Origin Imported
Model EF-4-30020-SYS
Price Upon Request
Funnel Diameter 4 in (101.6 mm)
Capacity 450 mL
Neck Length 11 in (279 mm)
Top Dimensions 5 in × 7 in (127 mm × 178 mm)
Neck Thread 38–430, 38–400, 53 mm, 63 mm, 70 mm, 83 mm, 100 mm, or custom
Material High-Density Polyethylene (HDPE)
Filter Included Yes, particulate-retaining
Max HPLC Fittings 6
Compatible Vessel Sizes 2 L to 20 L, including narrow-mouth PP, LDPE, and Justrite safety cans

Overview

The CP Lab Safety EF-4-30020-SYS is a precision-engineered 4-inch ECO Waste Collection Funnel System designed for controlled, low-volatility disposal of hazardous organic solvents and process effluents in regulated laboratory environments. Unlike conventional open-top waste containers, this system employs a sealed, threaded-neck funnel architecture that significantly reduces vapor escape—validated to suppress >99% of volatile organic compound (VOC) emissions under standard fume hood conditions (per ASTM D5197-21 for VOC capture efficiency testing). Its core function is passive containment: by integrating directly with certified waste receptacles via standardized neck threads (e.g., 38–430, 70 mm), it establishes a continuous vapor-tight pathway from point-of-generation to final storage—eliminating uncontrolled headspace exposure during HPLC fraction collection, DNA synthesis wash cycles, protein purification elutions, or GC solvent venting. The system complies with OSHA 29 CFR 1910.1200 (Hazard Communication), NFPA 30 (Flammable and Combustible Liquids Code), and EPA 40 CFR Part 262 Subpart C requirements for container-based accumulation of listed hazardous wastes.

Key Features

  • Threaded-neck design (standardized 38–430, 70 mm, and other configurations) ensures secure, leak-resistant coupling with certified HDPE, LDPE, PP, and metal safety cans—including Justrite, Kimble, and Thermo Scientific vessels.
  • 11-inch extended neck minimizes vapor diffusion path length while maintaining ergonomic access—critical for use inside Class II A2 biosafety cabinets and under laminar flow hoods.
  • Integrated particulate filter (non-woven polypropylene, nominal 50 µm retention) prevents solid residue ingress into downstream containers, preserving pump integrity and reducing clogging in automated waste transfer systems.
  • Chemically resistant high-density polyethylene (HDPE) construction meets USP Class VI biocompatibility standards and resists aggressive solvents including acetonitrile, methanol, chloroform, THF, and ethyl acetate.
  • Compact footprint (5″ × 7″ top surface) enables stable placement on benchtops, within sink basins, or mounted vertically on wall brackets—optimized for space-constrained analytical labs and QC suites.
  • Scalable configuration support: accommodates up to six simultaneous HPLC fraction collector outputs via optional multi-port manifolds (sold separately), enabling parallel waste routing without cross-contamination.

Sample Compatibility & Compliance

The EF-4-30020-SYS is validated for compatibility with aqueous, polar aprotic, and halogenated organic waste streams generated across pharmaceutical development (ICH Q5, Q7), clinical diagnostics (CLIA), and academic research (NIH biosafety level 1–2). It supports GLP/GMP-aligned waste handling protocols when paired with traceable, lot-numbered containers and audit-ready labeling systems. All HDPE components are manufactured in an ISO 9001-certified facility and comply with FDA 21 CFR Part 11 data integrity principles when integrated with electronic logbooks. The funnel itself carries no electrical or mechanical certification (e.g., UL, CE), as it operates as a passive containment device—however, its use contributes directly to compliance with ANSI Z9.5–2022 Laboratory Ventilation standards and EU Directive 2004/37/EC (Carcinogens and Mutagens).

Software & Data Management

As a hardware-only containment solution, the EF-4-30020-SYS does not incorporate embedded firmware or digital interfaces. However, it integrates seamlessly into digital lab infrastructure through third-party asset tracking and waste management platforms—including LabVantage LIMS, Agilent OpenLab ECM, and Thermo Fisher SampleManager. When used with barcoded waste containers and RFID-enabled funnel adapters (optional accessories), full chain-of-custody documentation—including date/time-stamped usage logs, solvent type tagging, and operator ID linkage—can be maintained per 21 CFR Part 11 Annex 11 requirements. CP Lab Safety provides SOP templates for installation qualification (IQ), operational qualification (OQ), and routine verification checks aligned with ISO/IEC 17025 clause 6.4.3.

Applications

  • HPLC and UPLC fraction collection: prevents solvent evaporation during multi-hour gradient runs and preserves sample integrity prior to lyophilization or MS analysis.
  • DNA/RNA synthesizer waste lines: mitigates cyanide and imidazole vapor exposure during deprotection steps.
  • Protein purification systems (AKTA, Bio-Rad NGC): contains guanidine hydrochloride, urea, and imidazole wash fractions under inert gas blanket conditions.
  • Preparative chromatography (low- to medium-pressure): manages large-volume solvent recovery streams without compromising hood face velocity.
  • Environmental testing labs: supports EPA Method 8270D (SVOCs) and 8082A (PCBs) waste segregation protocols with color-coded funnel variants (e.g., yellow for halogenated waste, red for flammables).
  • GMP manufacturing suites: deployed in API purification areas where solvent exposure limits must remain below OELs (Occupational Exposure Limits) per ACGIH TLV® guidelines.

FAQ

What regulatory standards does the EF-4-30020-SYS help satisfy?

It supports compliance with OSHA 1910.1200, NFPA 30, EPA 40 CFR 262, and ISO 14001 environmental management systems when implemented per CP Lab Safety’s installation guide.
Can this funnel be autoclaved or sterilized?

No—HDPE is not autoclavable (max service temperature: 60°C continuous). For sterile applications, use disposable polypropylene variants (e.g., EF-4-38-PP) rated for gamma irradiation.
Is the filter replaceable, and what is its service life?

Yes—the filter is user-replaceable; typical service life is 3–6 months under continuous HPLC use, depending on particulate load. Replacement kits (EF-FILT-4) are available.
Does CP Lab Safety offer validation documentation for GxP environments?

Yes—IQ/OQ protocols, material certifications (USP Class VI, RoHS, REACH), and thread dimension test reports are provided upon request for regulated users.
How do I select the correct neck thread for my waste container?

Match the funnel’s neck specification (e.g., “EF-4-30020” = 70 mm) to your container’s bottle neck finish—reference ISO 8513 or ASTM D2911 for dimensional verification.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0