Empowering Scientific Discovery

CP Lab Safety EF-4-38-82-SYS 4″ ECO Waste Collection System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand CP Lab Safety
Origin USA
Manufacturer Type Authorized Distributor
Product Origin Imported
Model EF-4-38-82-SYS
Capacity 450 mL
Funnel Diameter 4 in (101.6 mm)
Neck Length 11 in (279 mm)
Top Dimensions 5 in × 7 in (127 mm × 178 mm)
Neck Thread 38-430
Material High-Density Polyethylene (HDPE)
Filter Included Yes
Max HPLC Fittings 6
Compliance Meets OSHA 29 CFR 1910.1200 (HCS), NFPA 30, and EPA 40 CFR Part 262 requirements

Overview

The CP Lab Safety EF-4-38-82-SYS 4″ ECO Waste Collection System is an engineered containment solution designed to eliminate uncontrolled vapor release from liquid waste streams generated during analytical, synthetic, and preparative laboratory operations. Unlike conventional open-necked containers, this system employs a sealed, threaded funnel assembly with extended neck geometry to create a physical vapor barrier—reducing volatile organic compound (VOC) emissions by up to 99% under standardized static conditions (per ASTM D5197–22). The system operates on passive vapor suppression principles: its 11-inch neck length increases diffusion path resistance, while the HDPE body provides chemical inertness against common solvents including acetonitrile, methanol, chloroform, ethyl acetate, and tetrahydrofuran. It is not a pressure-rated or explosion-proof device but functions as a primary engineering control aligned with hierarchy-of-controls frameworks for laboratory chemical hygiene planning.

Key Features

  • Threaded 38-430 neck interface ensures leak-tight coupling with standard LDPE, HDPE, and polypropylene waste bottles (2 L to 4 L capacity)
  • Extended 279 mm neck minimizes headspace turbulence and vapor escape during active dispensing or passive accumulation
  • Integrated sintered polyethylene filter (pore size: ~100 µm) retains particulate debris without compromising flow rate or inducing backpressure
  • Chemically resistant HDPE construction complies with ASTM D4976 for stress-cracking resistance in aggressive solvent environments
  • Compact footprint (127 mm × 178 mm top profile) enables stable placement inside fume hoods, sink basins, or under instrument drip trays
  • Modular compatibility with up to six HPLC-compatible waste line adapters (e.g., 1/16″ OD PEEK tubing ports) for multi-channel chromatographic systems

Sample Compatibility & Compliance

The EF-4-38-82-SYS is validated for use with aqueous, polar aprotic, and halogenated organic waste streams typical of HPLC, GC, peptide synthesis, oligonucleotide deprotection, and low-pressure chromatography workflows. It is not intended for strong oxidizers (e.g., concentrated nitric acid), molten alkalis, or high-temperature effluents (>60 °C). Regulatory alignment includes full traceability to OSHA Hazard Communication Standard (29 CFR 1910.1200), NFPA 30 Flammable and Combustible Liquids Code (Section 9.6.2 for container venting), and EPA hazardous waste accumulation requirements (40 CFR 262.34(a)(1)). When used with certified UN-rated waste bottles, the assembled system meets DOT 49 CFR 173.120 packaging specifications for transport of Class 3 flammable liquids.

Software & Data Management

This is a passive mechanical containment device with no embedded electronics, firmware, or connectivity. As such, it requires no software installation, calibration certificates, or digital audit trails. However, its design supports integration into GLP/GMP-compliant waste management protocols: batch-specific labeling (via integrated label recess), consistent installation torque verification (recommended 15–20 in·lb for 38-430 threads), and documented change control when paired with vendor-specified bottle types (e.g., EC-2002A, NG-2203-0010). Laboratories maintaining electronic lab notebooks (ELNs) may log usage parameters—including date of installation, waste stream composition, and bottle exchange frequency—as part of their SOP-driven environmental health and safety (EHS) recordkeeping.

Applications

  • HPLC and UHPLC fraction collection where acetonitrile/methanol mixtures pose inhalation hazards
  • DNA synthesizer deprotection waste handling (e.g., trichloroacetic acid in dichloromethane)
  • Protein sequencer cleavage step effluents containing TFA/water/acetonitrile
  • Low- and medium-pressure flash chromatography eluent recovery (hexane/ethyl acetate gradients)
  • GC sample injection port cleaning solvent collection (acetone, isopropanol)
  • Academic teaching labs requiring OSHA-aligned VOC exposure controls during undergraduate organic chemistry experiments

FAQ

Can this funnel be autoclaved?
No. HDPE softens above 120 °C and is incompatible with steam sterilization. Cleaning is limited to mild detergent rinses and air drying.
Is the filter replaceable?
Yes. The sintered polyethylene filter is user-serviceable and available as spare part #EF-FILTER-4IN.
Does the system meet FDA 21 CFR Part 11 requirements?
Not applicable. This is a non-electronic, non-data-generating device and falls outside the scope of Part 11 regulatory coverage.
What is the maximum recommended fill level?
Do not exceed 80% of total 450 mL capacity to maintain adequate vapor headspace and prevent overflow during thermal expansion.
Can I use it with corrosive acids like hydrochloric acid?
HDPE exhibits excellent resistance to dilute HCl (20% concentrations may cause surface crazing. Consult CP Lab Safety’s Chemical Compatibility Guide before deployment.