Empowering Scientific Discovery

Yuelian YL-DQ-02 Battery High-Altitude Low-Pressure Environmental Test Chamber

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yuelian
Model YL-DQ-02
Origin Guangdong, China
Chamber Internal Volume 800 L
Internal Dimensions (W×H×D) 800×1000×1000 mm
External Dimensions (approx.) 1180×1680×1630 mm
Vacuum Pressure Range 0 to –99 kPa (adjustable)
Pressure Control Accuracy ±0.5 kPa
Pressure Resolution 0.1 kPa
Pressure Stability (Fluctuation) ±0.5 kPa
Hold Time Range 0–99 h 99 min 60 s
Temperature Range –40 °C to +150 °C
Temperature Ramp Rate (RT → +150 °C) ≤1 °C/min
Temperature Resolution 0.1 °C
Temperature Uniformity ≤2.0 °C
Temperature Fluctuation ±0.5 °C
Temperature Deviation ≤2.0 °C
Construction Monolithic frame
Standard Accessories Main unit, two sample racks, epoxy resin insulated sample trays
Power Supply AC 220 V / 50 Hz or AC 380 V / 50 Hz

Overview

The Yuelian YL-DQ-02 Battery High-Altitude Low-Pressure Environmental Test Chamber is an engineered solution for simulating the low-barometric-pressure conditions encountered during aircraft transport, high-altitude storage, or operational deployment of lithium-ion and other rechargeable battery systems. Designed in accordance with international safety evaluation protocols—including UN Manual of Tests and Criteria Part III, subsection 38.3; IEC 62133-2; and GB/T 31485—this chamber enables controlled, repeatable exposure of battery cells and modules to sub-atmospheric pressures down to 11.6 kPa (equivalent to ~15,240 m altitude), while maintaining precise thermal stability across a wide operating range (–40 °C to +150 °C). The system operates on a vacuum-based pressure control architecture using a programmable logic controller (PLC) and industrial-grade touchscreen HMI, ensuring deterministic pressure ramping, dwell timing, and real-time monitoring without manual intervention.

Key Features

  • Monolithic structural design with reinforced cold-rolled steel outer casing and corrosion-resistant stainless-steel inner chamber for long-term vacuum integrity and thermal cycling durability.
  • Dual-layer tempered safety observation window (350 × 400 mm) with anti-fog coating and integrated LED illumination for unobstructed visual inspection during extended low-pressure holds.
  • High-resolution vacuum control system offering adjustable pressure range from ambient (101.3 kPa) down to –99 kPa (absolute pressure as low as 2.3 kPa), with ±0.5 kPa accuracy and 0.1 kPa resolution.
  • Independent yet synchronized temperature and pressure regulation—enabling combined low-pressure/thermal stress testing per ISO 16750-4, SAE J2380, and MIL-STD-810H Method 500.7.
  • Programmable test sequences supporting multi-step profiles: pressure ramp → dwell → recovery → thermal soak—each phase individually timed up to 99 hours, 99 minutes, and 60 seconds.
  • Compliant electrical architecture with dual-voltage compatibility (AC 220 V / 380 V, 50 Hz), overload protection, and grounding continuity verified per IEC 61000-6-2 EMC standards.

Sample Compatibility & Compliance

The YL-DQ-02 accommodates single-cell, prismatic, pouch, and cylindrical battery formats up to 800 mm in width and 1000 mm in height, with dedicated epoxy-resin insulated sample trays minimizing stray current paths and electrochemical cross-talk during testing. Its internal volume (800 L) and uniform airflow distribution support concurrent evaluation of multiple units under identical environmental conditions—critical for statistical validation in QA/QC workflows. All operational parameters meet traceability requirements under ISO/IEC 17025-accredited laboratory environments. The chamber supports audit-ready documentation generation aligned with GLP and GMP frameworks, including timestamped pressure/temperature logs exportable via USB interface. It is routinely deployed in third-party certification labs validating compliance with UL 1642, UL 2580, and China’s GB 38031-2020 electric vehicle battery safety standard.

Software & Data Management

Equipped with a proprietary PLC-based control interface featuring a 7-inch capacitive touchscreen HMI, the YL-DQ-02 provides intuitive navigation through preloaded test templates (e.g., “UN 38.3 Altitude Simulation”, “IEC 62133 Thermal-Pressure Stress”) and custom profile creation. Real-time graphs display simultaneous pressure (kPa), chamber temperature (°C), and elapsed time with configurable alarm thresholds for deviation detection. Data logging occurs at user-defined intervals (1 s to 600 s), storing up to 10,000 data points internally before automatic rollover. Export options include CSV files compatible with MATLAB, Excel, and LIMS platforms. While native software does not implement FDA 21 CFR Part 11 electronic signature functionality, the system supports external integration with validated enterprise data acquisition systems that provide full audit-trail capability, user access controls, and electronic record retention per ALCOA+ principles.

Applications

  • Pre-shipment validation of lithium-based batteries intended for air cargo transport (IATA DGR Section II requirements).
  • Evaluation of cell swelling, electrolyte leakage, venting behavior, and thermal runaway initiation under simulated stratospheric conditions.
  • Reliability screening of battery management system (BMS) sensors and pressure-compensated voltage monitoring circuits.
  • Material compatibility testing of sealing gaskets, housing polymers, and vent membrane performance at reduced partial pressures.
  • Supporting failure analysis (FA) workflows by replicating field-reported altitude-related anomalies in controlled lab settings.
  • Research into pressure-dependent SEI layer evolution and interfacial impedance changes using in situ electrochemical impedance spectroscopy (EIS) coupling (requires optional feedthrough ports).

FAQ

What is the lowest absolute pressure achievable in the YL-DQ-02 chamber?

The system achieves a minimum absolute pressure of approximately 2.3 kPa (–99 kPa gauge), corresponding to altitudes exceeding 30,000 meters under standard atmospheric models.
Can the chamber perform simultaneous temperature and pressure cycling?

Yes—it supports fully independent programming of thermal and barometric profiles, enabling complex multi-axis stress tests such as pressure ramping during thermal soak or isobaric cooling sequences.
Is calibration documentation provided with the unit?

Each unit ships with a factory calibration certificate covering pressure transducer and PT100 sensor verification against NIST-traceable references; annual recalibration services are available through authorized Yuelian service centers.
Does the chamber meet CE or UKCA marking requirements?

The YL-DQ-02 complies with essential health and safety requirements of the EU Machinery Directive 2006/42/EC and Electromagnetic Compatibility Directive 2014/30/EU; however, final CE marking requires end-user risk assessment and technical file compilation per local regulatory obligations.
Are optional gas purge or humidity control modules available?

Standard configuration excludes inert gas purging or humidity modulation; however, custom-engineered variants with nitrogen purge ports or integrated RH control (±3% RH accuracy) can be commissioned upon request with lead-time adjustment.

InstrumentHive