Empowering Scientific Discovery

Yuelian YL-PS150 ASTM D3330 Standard Test Steel Plate for Peel Adhesion Testing

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yuelian
Origin Guangdong, China
Manufacturer Type Authorized Distributor
Country of Origin China
Model YL-PS150
Surface Roughness 50 ± 25 nm (per GB/T 2523–2008)
Material 06Cr19Ni10 Stainless Steel (equivalent to AISI 304, UNS S30400)
Dimensions 125 mm × 50 mm × 1.1 mm
Surface Condition Annealed & Mirror-Polished
Compliance GB/T 3280–2007, ASTM D3330, ISO 8510-2, PSTC-101

Overview

The Yuelian YL-PS150 is a precision-engineered stainless steel test plate designed exclusively for standardized peel adhesion testing in accordance with ASTM D3330, ISO 8510-2, and PSTC-101 methodologies. It serves as the mandatory substrate for evaluating the peel strength of pressure-sensitive adhesives (PSAs), tapes, labels, and laminated films under controlled laboratory conditions. The plate operates on the principle of providing a geometrically stable, chemically inert, and metrologically traceable surface—ensuring inter-laboratory reproducibility and regulatory acceptability. Its 06Cr19Ni10 composition (AISI 304-grade austenitic stainless steel) delivers high corrosion resistance, thermal stability, and non-reactivity with organic solvents and adhesive chemistries commonly used in PSA formulation. The mirror-polished, annealed finish eliminates microstructural anisotropy, while the rigorously controlled surface roughness—50 ± 25 nm RMS (measured per GB/T 2523–2008, equivalent to ISO 4287)—ensures consistent contact area and interfacial energy during peel initiation and propagation.

Key Features

  • Dimensionally certified plate: 125 mm length × 50 mm width × 1.1 mm thickness—fully compliant with ASTM D3330 specimen mounting requirements and fixture compatibility.
  • High-purity 06Cr19Ni10 stainless steel, conforming to GB/T 3280–2007 mechanical and chemical specifications; equivalent to ASTM A240/A240M Grade 304.
  • Surface roughness maintained at 50 ± 25 nm (Ra), verified via calibrated atomic force microscopy (AFM) or stylus profilometry traceable to NIM (National Institute of Metrology, China) standards.
  • Mirror-finish annealed surface ensures minimal topographic interference during peel front propagation—critical for eliminating edge effects and achieving stable 90° or 180° peel force profiles.
  • Supplied with individual certification documentation including material lot number, roughness verification report, and heat treatment record—supporting GLP-compliant test documentation.
  • Designed for single-use or limited-reuse protocols: surface integrity must be verified prior to each test series using optical inspection and profilometric re-check to prevent data drift from micro-scratches or contamination.

Sample Compatibility & Compliance

The YL-PS150 plate is validated for use with all major PSA types—including acrylics, rubber-based, silicone, and hot-melt adhesives—as well as medical-grade tapes and barrier laminates. Its surface energy (~46 mN/m) provides representative wetting behavior for standard PSA formulations without requiring silanization or plasma activation. Regulatory alignment includes full traceability to ISO/IEC 17025-accredited calibration practices, supporting audit readiness for FDA 21 CFR Part 11 (when paired with compliant data acquisition systems), EU MDR Annex I requirements for adhesive performance validation, and ICH Q5E comparability studies. Each batch undergoes third-party verification against ASTM D3330 Annex A1 surface qualification criteria, including visual inspection under 10× magnification and solvent wipe resistance testing per ASTM D2244.

Software & Data Management

While the YL-PS150 itself is a passive reference substrate, its integration into peel testing workflows requires strict procedural governance. When used with universal testing machines (e.g., Instron 5940, Zwick Roell Z005), it supports automated data capture through compliant software platforms such as Bluehill Universal (Instron) or testXpert II (Zwick), both offering 21 CFR Part 11-compliant audit trails, electronic signatures, and raw force–displacement curve archiving. Users are required to log plate ID, usage count, cleaning history, and surface verification results within their LIMS or ELN—ensuring full chain-of-custody for GMP/GLP environments. Calibration certificates include uncertainty budgets for roughness measurement (k = 2), referenced to SI-traceable standards.

Applications

  • Quality control of pressure-sensitive adhesive tapes per ASTM D3330 Type A (90° peel) and Type B (180° peel).
  • Regulatory submission testing for medical device labeling (ISO 15223-1, EN 980) and transdermal patch adhesion (USP ).
  • R&D screening of novel adhesive formulations under accelerated aging (ASTM D1876, ISO 11339).
  • Interlaboratory round-robin studies coordinated under ISO/IEC 17043 proficiency testing schemes.
  • Validation of automated peel testers used in high-volume manufacturing lines (e.g., automotive trim bonding, electronics assembly).

FAQ

How often should the YL-PS150 plate be replaced?
Replace after no more than five complete peel test cycles—or immediately upon detection of visible scratches, discoloration, or roughness deviation exceeding ±25 nm during verification.
Can the plate be cleaned and reused between tests?
Yes—only with lint-free wipes saturated in analytical-grade isopropyl alcohol (IPA), followed by nitrogen drying; never use abrasive cloths or ultrasonic cleaning, which may alter surface topography.
Is this plate suitable for high-temperature peel testing?
The 06Cr19Ni10 substrate remains dimensionally stable up to 400 °C, but adhesive performance—not substrate integrity—is the limiting factor; verify thermal compatibility per ASTM D1002 for elevated-temperature protocols.
Does the YL-PS150 meet FDA requirements for medical device testing?
Yes—material compliance with ASTM F899 (standard specification for stainless steels for surgical instruments) and surface certification per ISO 10993-12 support biocompatibility assessment workflows.
What documentation accompanies each plate shipment?
Each unit ships with a Certificate of Conformance (CoC) listing material grade, dimensional verification, roughness report, annealing certificate, and GB/T 3280–2007 compliance statement.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0