Kanomax 6036 Intelligent Environmental Anemometer
| Brand | Kanomax |
|---|---|
| Model | 6036-0C / 6036-BC |
| Type | Thermal Anemometer |
| Resolution | 0.01 m/s |
| Measurement Range | 0.01–30.0 m/s |
| Accuracy | ±3% of reading (wind speed), ±0.5 °C (temperature), ±3% of reading (pressure, –0.00 to ±5 kPa) |
| Operating Temperature | –20 °C to +70 °C |
| Operating Humidity | 0–100% RH |
| Data Storage Capacity | 1500 records |
| Interface | USB |
| Dimensions | 66 × 51 × 188 mm |
| Weight | 400 g (without batteries) |
| Probe | Flexible and telescopic |
Overview
The Kanomax 6036 Intelligent Environmental Anemometer is a handheld, multi-parameter thermal anemometer engineered for precision air velocity, volumetric airflow, temperature, and differential pressure measurement in HVAC commissioning, indoor air quality (IAQ) assessment, cleanroom validation, and industrial ventilation audits. Based on constant-temperature anemometry (CTA), the device employs a heated thermistor sensor whose cooling rate correlates linearly with local air velocity—enabling high-sensitivity detection down to 0.01 m/s. Unlike cup or vane anemometers, its thermal sensing principle ensures minimal flow disturbance, directional independence, and stable response across turbulent and low-velocity regimes typical in ductwork, fume hoods, and laminar flow cabinets. The instrument integrates real-time cross-sectional geometry input (rectangular, circular, or irregular duct profiles) to compute volumetric airflow (m³/h or CFM) directly—eliminating manual calculation errors and supporting ASHRAE Guideline 12 and ISO 16813-compliant air balance procedures.
Key Features
- Simultaneous real-time measurement of air velocity (0.01–30.0 m/s), temperature (–20 °C to +70 °C), and differential pressure (–5.0 to +5.0 kPa)
- Telescopic and articulating probe with 360° bendable stainless-steel shaft for access to confined or offset duct locations
- On-device statistical functions: hold, min/max/avg calculation, and auto-zero for pressure channel
- Internal memory stores up to 1500 timestamped data sets with channel-specific metadata (date, time, user ID, duct ID)
- USB interface compliant with USB 2.0 full-speed standard; supports direct connection to Windows-based PCs without external drivers
- Rugged ABS+PC housing rated IP54 for dust and splash resistance; operational under ambient humidity 0–100% RH (non-condensing)
- Low-power design with alkaline AA battery operation (approx. 20 hours continuous use); battery status indicator and auto-power-off after 10 minutes idle
Sample Compatibility & Compliance
The Kanomax 6036 is validated for use across diverse sampling environments including rectangular supply/return ducts, round exhaust pipes, grille face measurements, and laminar airflow workbenches. Its thermal sensor exhibits negligible sensitivity to particulate loading within ISO Class 8 cleanroom conditions and maintains accuracy under transient thermal gradients common during seasonal HVAC startup. The instrument conforms to IEC 61000-4 electromagnetic compatibility standards and meets mechanical safety requirements per IEC 61010-1 for portable electrical measuring equipment. While not certified for intrinsic safety (ATEX/IECEx), it is routinely deployed in non-hazardous industrial zones per OSHA 1910.169 and EU Directive 2006/42/EC. Calibration traceability follows NIST-traceable reference standards, with optional factory calibration certificates available per ISO/IEC 17025 requirements.
Software & Data Management
Kanomax provides proprietary PC software (Kanomax Data Viewer v3.x, Windows 10/11 compatible) for post-acquisition analysis. The application enables drag-and-drop import of .csv or native .kdx files, graphical overlay of velocity/temperature/pressure trends, duct geometry-driven airflow profile mapping, and automated report generation in PDF or Excel format—including headers compliant with GLP documentation templates. Audit trail functionality logs all user-initiated actions (data export, parameter modification, calibration date entry) with timestamps and operator IDs—supporting FDA 21 CFR Part 11 readiness when configured with electronic signature modules. Raw data exports retain full resolution (0.01 m/s, 0.1 °C, 0.01 kPa) without rounding or interpolation.
Applications
- HVAC system balancing per ASHRAE Standard 111 and EN 12599
- ISO 14644-3 cleanroom airflow uniformity and velocity mapping
- Pharmaceutical facility environmental monitoring (Grade A–D zones)
- Industrial hygiene assessments for respirable dust control ventilation efficacy
- Educational laboratory instruction in fluid mechanics and thermal physics
- Energy audit pre- and post-retrofit airflow verification
FAQ
Does the 6036 support automatic duct area calculation for non-rectangular geometries?
Yes—it accepts user-defined polygonal duct cross-sections via vertex coordinate input, enabling accurate airflow integration for irregular shapes such as oval or trapezoidal ducts.
Is pressure measurement referenced to ambient or sealed gauge?
The pressure channel uses a piezoresistive differential sensor with internal reference cavity; readings are relative to ambient atmospheric pressure unless externally zeroed against a known static reference.
Can stored data be exported without the Kanomax software?
Yes—internal memory exports plain-text CSV files via USB mass storage mode, fully compatible with Excel, Python pandas, or LabVIEW for custom analysis pipelines.
What is the recalibration interval recommendation?
Kanomax recommends annual recalibration against NIST-traceable wind tunnel and dry-well references; field verification using calibrated reference anemometers is advised before critical measurements.
Is the probe interchangeable with other Kanomax models?
No—the 6036 uses a proprietary probe interface; probes from models 6162, 6501, or 6705 are mechanically and electrically incompatible.