Kanomax 6006 Hot-Wire Anemometer
| Brand | Kanomax |
|---|---|
| Origin | Japan |
| Model | 6006 |
| Instrument Type | Hot-Wire Anemometer |
| Velocity Range | 0.01–20.0 m/s |
| Resolution | 0.01 m/s (0.01–9.99 m/s) |
| Accuracy | ±5% of reading |
| Temperature Range | −20 to +70 °C |
| Temperature Accuracy | ±1.0 °C |
| Operating Humidity | 20–85% RH |
| Power Supply | 4 × AA batteries |
| Dimensions | 60 × 120 × 34 mm |
| Weight | 180 g |
Overview
The Kanomax 6006 is a handheld, battery-powered hot-wire anemometer engineered for precise, real-time measurement of air velocity and ambient temperature in industrial, HVAC, cleanroom, and environmental monitoring applications. Utilizing constant-temperature anemometry (CTA), the device maintains a heated sensing element at a stable thermal equilibrium; airflow-induced cooling is converted into proportional electrical signals, enabling high-sensitivity detection down to 0.01 m/s. Its compact form factor—measuring just 60 × 120 × 34 mm and weighing only 180 g—facilitates single-handed operation in confined or elevated spaces, while its dual-sensor capability allows simultaneous acquisition of velocity and temperature data without requiring external modules or software synchronization.
Key Features
- Integrated hot-wire sensor with auto-zeroing function and thermal drift compensation for stable low-velocity measurements
- Simultaneous display of air velocity and ambient temperature on a backlit LCD screen with intuitive icon-based interface
- Interchangeable probe design supports optional accessories—including extended-length probes and vane-type adapters—for versatile sampling geometries
- Rugged, ergonomic housing rated for operation across −20 to +70 °C and 20–85% RH, suitable for both indoor and semi-outdoor field use
- Low-power architecture enables up to 20 hours of continuous operation on four standard AA alkaline cells
- Zero-point calibration accessible via front-panel button sequence—no PC or service tool required
Sample Compatibility & Compliance
The Kanomax 6006 is optimized for measuring laminar and turbulent airflow in ducts, fume hoods, biological safety cabinets, and ventilation grilles. It complies with ISO 7726:1998 (Ergonomics of the thermal environment — Instruments for measuring physical quantities) for thermal comfort assessment and meets the general performance criteria outlined in ANSI/ASHRAE Standard 111–2013 (Methods of Testing for Rating Airflow Measurement Devices). While not certified for explosion-proof or intrinsically safe environments, its non-sparking electronics and absence of moving parts make it appropriate for routine QA/QC tasks in pharmaceutical manufacturing, semiconductor fab facilities, and laboratory HVAC commissioning where traceable, repeatable velocity profiling is required.
Software & Data Management
The instrument operates as a standalone measurement tool with no embedded memory or USB connectivity. All data logging must be performed manually or via external recording devices. However, its consistent output resolution and linear response curve enable seamless integration with third-party DAQ systems using analog voltage outputs (available via optional interface cable). For regulated environments operating under GLP or GMP frameworks, users may implement documented manual recording procedures supported by the device’s stable zero-hold functionality and factory-traceable calibration certificate (provided upon request). The unit does not support FDA 21 CFR Part 11-compliant electronic signatures or audit trails, and therefore is intended for non-critical process monitoring or preliminary survey work rather than final release testing.
Applications
- HVAC system balancing and airflow verification in commercial buildings and hospitals
- Validation of laminar flow hoods and cleanroom ISO Class 5–8 air curtain integrity
- Occupational health assessments of local exhaust ventilation (LEV) capture velocity
- Field verification of fan coil unit output and diffuser discharge profiles
- Educational demonstrations of convective heat transfer and boundary layer development
- Baseline environmental surveys prior to ISO 14644-3 or EU GMP Annex 1 compliance audits
FAQ
Does the Kanomax 6006 support data logging?
No—the device lacks internal memory or serial/USB export capability. Measurements must be recorded manually or captured externally via analog output.
Can the probe be replaced or calibrated in-house?
Yes—the hot-wire probe is user-replaceable using Kanomax part number 6006-PROBE. Field calibration requires a NIST-traceable reference anemometer and is recommended annually or after mechanical shock.
Is the instrument suitable for outdoor wind speed measurement?
It is not designed for unsheltered outdoor use due to sensitivity to precipitation, direct solar loading, and rapid humidity fluctuations. Use is restricted to controlled or sheltered environments per specifications.
What is the warm-up time before stable readings?
Approximately 30 seconds from power-on to thermal stabilization of the sensing wire under typical ambient conditions.
Does it meet ISO 17025 requirements for accredited laboratories?
The instrument itself is not ISO/IEC 17025-accredited, but when used with a valid calibration certificate issued by an ILAC-MRA signatory lab, it may serve as a compliant secondary standard within an accredited facility’s uncertainty budget.