Empowering Scientific Discovery

KANOMAX Anemometer Air Flow Meter – Model 6162 (Thermal Anemometer with Multi-Parameter Environmental Monitoring Capability)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand KANOMAX
Origin Japan
Instrument Type Thermal Anemometer
Resolution 0.01 m/s
Measurement Range Dependent on Interchangeable Probe (e.g., 0.05–30 m/s for standard hot-wire probe)
Accuracy ±2% of reading
Operating Temperature −20 to +70 °C
Operating Humidity 2.0–98.0% RH
Data Storage Capacity Up to 20,000 records
Probe Interface Standardized 8-pin detachable connector supporting eight interchangeable probe types
Built-in Calculations Volumetric airflow (m³/h, CFM) via user-defined duct geometry (rectangular, circular, oval cross-sections with dimensional input)
On-device Statistics Real-time min/max/average of velocity, temperature, humidity, and pressure
Data Hold & Recall Instant freeze-display and historical retrieval
Accessories Included 2 m probe cable ×1, carrying case ×1, operation manual ×1

Overview

The KANOMAX Model 6162 is a high-precision thermal anemometer engineered for simultaneous, real-time measurement of air velocity, volumetric airflow, ambient temperature, relative humidity, and differential pressure. Utilizing constant-temperature anemometry (CTA) principles, the instrument maintains a heated sensing element at a fixed temperature differential above ambient; convective heat loss from the element correlates linearly with airflow velocity—enabling robust, low-inertia response across turbulent and laminar flow regimes. Designed for field-deployable accuracy and laboratory-grade repeatability, the 6162 integrates environmental metrology into a single handheld platform without compromising traceability or operational integrity. Its architecture complies with ISO 7726 (Ergonomics of the thermal environment — Instruments for measuring physical quantities) and supports calibration traceability to NIST-traceable standards through KANOMAX’s certified service network.

Key Features

  • Multi-parameter acquisition: Simultaneous sampling of velocity (m/s), temperature (°C), RH (%), and pressure (Pa) at up to 1 Hz update rate.
  • Modular probe system: Eight mechanically and electrically compatible probes—including vane, hot-wire, pitot-static, and thermal sphere variants—interchangeable via a ruggedized 8-pin quick-connect interface.
  • Duct airflow computation engine: Supports user-defined duct geometry (circular, rectangular, oval) with dimension entry (mm or inches); automatically calculates volumetric flow rate (m³/h, CFM) using ISO 12354-3 and ASHRAE Guideline 12–2020 methodologies.
  • On-device statistical processing: Continuous calculation and display of min, max, and arithmetic mean values over user-specified intervals (1 s to 60 min).
  • Non-volatile data logging: Stores up to 20,000 timestamped records (including date/time, all measured parameters, and computed airflow) with automatic rollover and USB-C export capability.
  • Environmental resilience: IP54-rated enclosure; operational performance validated across −20 to +70 °C and 2–98% RH per IEC 60529 and IEC 60068-2-1/2/30.

Sample Compatibility & Compliance

The Model 6162 accommodates diverse sampling configurations—from cleanroom HEPA filter face scans and HVAC duct traverses to industrial exhaust stack profiling and indoor air quality (IAQ) baseline surveys. Probe selection determines application suitability: hot-wire probes (e.g., 6501 series) enable low-velocity resolution (15 m/s). The instrument meets EN 13725 (ambient air quality — measurement of VOCs), ISO 16814 (HVAC systems — air velocity measurement), and aligns with FDA 21 CFR Part 11 requirements when used with optional audit-trail-enabled software (KANOMAX AirLog Pro v3.2).

Software & Data Management

KANOMAX AirLog Pro software (Windows/macOS) enables post-acquisition analysis, report generation (PDF/CSV), and compliance documentation. Features include automated GMP/GLP audit trails, electronic signature support, customizable templates for ASHRAE 110, ISO 14644-3, and EU GMP Annex 1 validation protocols, and batch-level metadata tagging (operator ID, location tag, calibration certificate ID). Raw data exports retain full time-stamped parameter sets, enabling third-party integration with LIMS or building management systems (BMS) via OPC UA or Modbus TCP gateways.

Applications

  • HVAC commissioning and TAB (Testing, Adjusting, Balancing) per SMACNA and NEBB standards.
  • Cleanroom classification (ISO 14644-1) and recirculation ratio verification.
  • Pharmaceutical facility environmental monitoring (Grade A–D zones) under EU GMP Annex 1.
  • Industrial hygiene assessments per OSHA Technical Manual Section III: Chapter 2 (Air Sampling).
  • Energy audit workflows including duct leakage quantification and fan efficiency evaluation (ASHRAE Fundamentals Ch. 23).
  • Academic research in boundary layer meteorology, ventilation effectiveness studies, and thermal comfort modeling (PMV/PPD).

FAQ

What calibration standards does the Model 6162 support?
It accepts NIST-traceable calibrations performed by KANOMAX-certified labs; factory calibration certificates include uncertainty budgets per ISO/IEC 17025.
Can the device log data without a PC connection?
Yes—internal memory retains 20,000 records independently; USB-C connection is required only for export or firmware updates.
Is probe interchangeability limited to KANOMAX-branded probes?
Only KANOMAX 6162-compatible probes (part numbers prefixed 65xx) are electrically and mechanically validated; third-party probes void warranty and compromise accuracy claims.
Does the instrument meet FDA 21 CFR Part 11 requirements out-of-the-box?
Hardware supports secure data integrity; full Part 11 compliance requires AirLog Pro v3.2 with enabled audit trail, role-based access control, and electronic signature modules.
How is airflow calculated for non-standard duct shapes?
Users define custom cross-sectional geometry via coordinate input (e.g., polygonal ducts); the device applies numerical integration across discrete traverse points per ISO 12354-3 Annex B.