Empowering Scientific Discovery

KANOMAX Model 6824 Vane Anemometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand KANOMAX
Origin Japan
Model 6824
Instrument Type Vane Anemometer
Velocity Range 0.2–20.0 m/s
Accuracy ±3% of reading or ±0.1 m/s (whichever is greater)
Temperature Range −20 to +100 °C
Temperature Accuracy ±1.0 °C
Air Volume Range 0–9,999 CFM
Probe Diameter 70 mm
Power Source Alkaline batteries
Battery Life Approx. 150 hours
Dimensions (W×H×D) 81 × 165 × 38 mm
Weight 175 g (including batteries)

Overview

The KANOMAX Model 6824 Vane Anemometer is a precision-engineered handheld instrument designed for reliable, repeatable measurement of air velocity, temperature, and volumetric airflow in HVAC commissioning, industrial ventilation assessment, cleanroom qualification, and environmental health & safety (EHS) applications. Based on the proven principle of rotational torque sensing—where airflow imparts angular momentum to a calibrated vane rotor—the device delivers stable analog-to-digital conversion of rotational speed into velocity output with minimal thermal drift. Its robust mechanical architecture supports operation across an extended ambient temperature range (−20 to +100 °C), making it suitable for both cold storage facility surveys and high-temperature duct inspections. Unlike thermal anemometers, the vane-based transduction mechanism ensures immunity to humidity-induced signal attenuation and provides consistent response in turbulent or pulsating flows typical of supply grilles, exhaust hoods, and fume cabinets.

Key Features

  • Vane-type sensing element with precision-balanced aluminum rotor for low-inertia, rapid response (t90 < 1.5 s) to dynamic airflow changes
  • Simultaneous real-time display of air velocity (m/s), temperature (°C/°F), and calculated volumetric flow (CFM or m³/h) on a high-contrast LCD
  • Integrated cross-sectional area input function: users enter duct geometry (rectangular, circular, or irregular) and dimensions to auto-calculate total airflow without external computation
  • IP54-rated housing with ergonomic grip and recessed probe mount for one-handed operation during ceiling-mounted or confined-space measurements
  • Low-power design enabling >150 hours of continuous use on standard AA alkaline cells; auto-power-off after 10 minutes of inactivity
  • Calibration traceable to JIS Z 8000-2 and ISO/IEC 17025-accredited reference standards; factory calibration certificate provided with each unit

Sample Compatibility & Compliance

The Model 6824 is optimized for use with standard HVAC components including supply diffusers, return grilles, filter banks, and exhaust stacks. Its 70 mm diameter vane probe accommodates most common duct sizes while maintaining laminar flow capture at inlet faces. The instrument complies with ASTM D1896-22 (Standard Practice for Measuring Air Velocity in Ventilation Ducts) and supports adherence to ASHRAE Guideline 12–2020 (Managing the Risk of Legionellosis Associated with Building Water Systems) through validated airflow verification. For regulated environments, data logging functionality (when used with optional PC interface cable and KANOMAX DataViewer software) enables audit-ready records compliant with GLP and GMP documentation requirements, including timestamped entries and user ID tagging.

Software & Data Management

KANOMAX DataViewer (v4.2+) provides full bidirectional communication via USB-to-serial adapter (optional accessory). Users can configure sampling intervals (0.1–60 s), define custom duct profiles, export CSV-formatted datasets with metadata (date/time, operator ID, location tag), and generate summary reports aligned with ISO 16813:2006 (HVAC performance evaluation). All exported files include embedded calibration status flags and uncertainty estimates per GUM (Guide to the Expression of Uncertainty in Measurement). The software supports 21 CFR Part 11-compliant electronic signatures when deployed on validated Windows workstations within controlled IT environments.

Applications

  • HVAC system balancing and TAB (Testing, Adjusting, and Balancing) per NEBB Procedural Standards
  • Occupational exposure assessment per OSHA Technical Manual Section III: Chapter 2 (Ventilation)
  • Cleanroom airflow uniformity mapping in accordance with ISO 14644-3 Annex B
  • Exhaust hood face velocity validation per ANSI/AIHA Z9.5–2022 Laboratory Ventilation Standard
  • Post-maintenance verification of fan performance following filter replacement or damper recalibration
  • Energy audit baseline measurements for ASHRAE Level I and II assessments

FAQ

What is the recommended recalibration interval for the Model 6824?
KANOMAX recommends annual recalibration under normal use conditions; however, facilities operating under ISO/IEC 17025 or FDA-regulated quality systems may require more frequent verification based on risk assessment.
Can the instrument measure airflow in non-rectangular ducts?
Yes—the device accepts user-defined cross-sectional geometries, including trapezoidal, oval, and irregular shapes, and calculates equivalent area using numerical integration algorithms.
Is the temperature sensor interchangeable or field-replaceable?
No—the NTC thermistor is integrated into the probe assembly and sealed during manufacturing; replacement requires factory service to maintain metrological integrity.
Does the Model 6824 meet CE or UKCA marking requirements?
Yes—it carries CE marking per Directive 2014/30/EU (EMC) and 2011/65/EU (RoHS), and is UKCA-marked for post-Brexit compliance in Great Britain.
How does the device handle low-velocity measurements below 0.5 m/s?
At velocities <0.5 m/s, the instrument applies a proprietary low-speed compensation algorithm that corrects for bearing friction and static drag, ensuring linearity down to the specified lower limit of 0.2 m/s.