Empowering Scientific Discovery

KANOMAX Model 6006 Hot-Wire Anemometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand KANOMAX
Origin Japan
Instrument Type Hot-Wire Anemometer
Measurement Range 0.01–20.0 m/s
Resolution 0.01 m/s (0.01–9.99 m/s), 0.1 m/s (10.0–20.0 m/s)
Accuracy ±5% of reading (wind speed), ±1°C (temperature)
Operating Temperature −20–70°C (probe), 5–40°C (main unit)
Operating Humidity 20–85% RH
Response Time <1 s (90% for wind speed at 1 m/s), <30 s (90% for temperature)
Display Features Battery level (4-segment), FAST/SLOW averaging (1 s / 5 s), unit toggle (m/s/°C ↔ fpm/°F), hold function
Probe Dimensions Ø6.1 mm (Ø10.6 mm at tip) × 205 mm
cable Ø3.3 mm × ~1.5 m
Main Unit Dimensions 60 × 120 × 30 mm
Weight ~180 g (including batteries)
Compliance Designed for ISO 7726-compliant thermal environment assessment, suitable for HVAC commissioning and indoor air quality (IAQ) surveys per ASHRAE Standard 111 and EN 13790

Overview

The KANOMAX Model 6006 is a handheld, battery-powered hot-wire anemometer engineered for high-reproducibility measurement of low- to medium-velocity airflows in environmental and industrial settings. Based on constant-temperature anemometry (CTA), the instrument maintains a precisely regulated temperature differential between a fine platinum wire sensor and ambient air, enabling linear voltage-to-velocity conversion across its full dynamic range. Its core design prioritizes field robustness, intuitive operation, and metrological traceability—making it especially suited for HVAC system verification, cleanroom airflow mapping, laboratory ventilation validation, and occupational hygiene assessments where real-time, portable velocity data are required under variable thermal conditions.

Key Features

  • Single-button interface with tactile feedback for power, measurement start/stop, and mode selection—minimizing operational complexity in glove-required or constrained environments.
  • Interchangeable probe assembly with factory-calibrated sensor element, ensuring consistent accuracy across multiple units without recalibration when used within specified environmental limits.
  • Integrated temperature compensation circuitry active across −20°C to +70°C probe operating range, delivering optimized wind speed accuracy (±5% of reading) within the 10–40°C ambient band per ISO 7726 Annex B guidelines.
  • Dual-range digital display with automatic resolution switching: 0.01 m/s resolution below 10 m/s, transitioning to 0.1 m/s above—supporting both laminar flow characterization and turbulent duct velocity profiling.
  • Configurable averaging modes (FAST: 1-second moving average; SLOW: 5-second moving average) to suppress short-term turbulence artifacts while preserving temporal fidelity for trend analysis.
  • Unit conversion via DIP switch: selectable output in SI (m/s, °C) or Imperial (fpm, °F) units—facilitating compliance with regional reporting standards in multinational facilities.

Sample Compatibility & Compliance

The Model 6006 is validated exclusively for use with ambient air at standard atmospheric pressure (80–106 kPa). It is not rated for corrosive, explosive, or particulate-laden gas streams. Probe construction (stainless steel sheath, PTFE-insulated leads) ensures chemical resistance appropriate for typical indoor and light-industrial environments. The device meets electromagnetic compatibility requirements per IEC 61326-1 (industrial environment), and its thermal response characteristics align with ASHRAE Standard 111’s criteria for airflow instrumentation used in building commissioning. While not certified to FDA 21 CFR Part 11, its analog signal path and non-networked architecture support standalone GLP/GMP-aligned recordkeeping when paired with manual log sheets or validated external data acquisition systems.

Software & Data Management

The Model 6006 operates as a self-contained measurement terminal with no embedded memory or digital communication ports (e.g., USB, Bluetooth, RS-232). All data must be recorded manually or captured externally via analog output (optional accessory). This architecture eliminates firmware update dependencies and cyber-security vulnerabilities associated with connected instruments—advantageous in regulated laboratories requiring audit-trail simplicity and long-term calibration stability. The built-in battery-level indicator (4-segment LED) and low-battery warning prevent unexpected shutdown during critical measurements, supporting uninterrupted field surveys lasting up to 20 hours on two AA alkaline cells.

Applications

  • HVAC duct traverse surveys per ANSI/ASHRAE Standard 111 for volumetric flow rate derivation.
  • Cleanroom ISO Class 5–8 airflow uniformity testing, including supply diffuser velocity profiling and laminar flow bench validation.
  • Occupational exposure assessment per ACGIH TLV® guidelines for local exhaust ventilation (LEV) capture velocity verification.
  • Thermal comfort evaluation in accordance with ISO 7730, using concurrent wind speed and dry-bulb temperature readings.
  • Educational demonstrations of convective heat transfer principles and boundary layer development in engineering labs.
  • Post-installation commissioning of fume hoods, biosafety cabinets, and paint spray booths.

FAQ

Is the Model 6006 suitable for measuring airflow in flue gases or combustion exhaust?
No. It is calibrated and validated only for ambient air at near-atmospheric pressure and non-corrosive composition.
Can the probe be sterilized for use in aseptic environments?
The probe housing is wipe-clean compatible with 70% isopropyl alcohol; autoclaving or ethylene oxide treatment is not recommended due to sensor thermal drift risk.
Does KANOMAX provide NIST-traceable calibration certificates with purchase?
Yes—certificates compliant with ISO/IEC 17025 are available as optional accessories, including as-found/as-left data and uncertainty budgets per ILAC-P10.
What is the recommended recalibration interval?
Annual recalibration is advised for routine QA/QC use; more frequent intervals may be required in high-use or thermally aggressive environments.
Is the instrument compatible with KANOMAX’s legacy 6004 accessories?
Mechanically and electrically compatible—probes, extension rods, and carrying cases designed for the 6004 are fully interchangeable with the 6006.