Empowering Scientific Discovery

Heyer Trading (Beijing) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPhi-TEC II
Price RangeUSD 135,000–270,000 (FOB UK)
Instrument TypeAccelerating Rate Calorimeter (ARC)
Measurement ModeAdiabatic Calorimetry
Temperature Range−80 °C to 500 °C
Temperature Resolution0.001 K
Temperature Accuracy (Direct Sample Mode)±0.001 °C
Temperature Tracking RateUp to 400 °C/min (Low-Φ mode)
Standard50 °C/min
Pressure Range0–300 bar (optional up to 1000 bar)
Pressure Tracking Rate0–200 bar/min (optional 700 bar/min)
Pressure Accuracy±0.05% FS
Pressure Resolution0.01 bar
Heat Release Detection Sensitivity0.002–0.2 °C/min
Sample Mass Capacity0.5–80 g
Adiabatic Correction Factor (Φ)≤1.05 (optimized for Phi-TEC II)
Outer & Inner Dewar Volume60 mL each
Thermal Capacity60,000 J
Single-Test DurationUp to 1000 min
StirringElectromagnetic, 0–500 rpm (mechanical option available)
Operating ModesHWS (Heat-Wait-Search), RAMP, ISO (Isothermal)
Dimensions30 cm × 37 cm × 50 cm
Power Supply220 V AC, 13 A, single-phase
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelPolyBLOCK 8
Reactor TypeModular Parallel Reaction System
Number of Independent Zones8
Temperature Range–60 °C to +230 °C (per zone)
Max. Inter-Zone ΔT100 °C
Vessel CompatibilityStandard and custom vessels (1–500 mL)
Vessel Diameter Limit48 mm
Vessel Depth Limit58 mm
Platform Dimensions350 × 200 × 200 mm
StirringHovering mechanical stirrer (standard), configurable for heterogeneous systems and crystallization
SoftwareWinISO v7+ (Windows-based, FDA 21 CFR Part 11 compliant audit trail optional)
Data ExportNative .csv, .xlsx, and time-stamped binary formats
Optional ModulesAutomated liquid dosing (multi-channel syringe pumps + multi-port valves), inline calorimetry (reaction heat flow), reflux & inert gas manifolds, pH/turbidity/pressure sensor integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelBioVIS
Construction MaterialStainless Steel (316L)
Maximum Working Pressure0.1 MPa (gauge)
Vacuum Range0–1 MPa (absolute)
Compatible Vessel CapacityUp to 5 L
SterilizationAutoclavable (121 °C, 20 min, steam)
Probe Length OptionsStandard 100 mm, 150 mm, 200 mm, or custom-engineered lengths
Measurement PrincipleIn-situ optical backscatter at multiple wavelengths (650 nm & 850 nm) with temperature-compensated signal processing
Output Interface4–20 mA analog + RS-485 Modbus RTU
IP RatingIP68
ComplianceCE-marked, RoHS-compliant, compatible with ISO 13485 and FDA 21 CFR Part 11–enabled SCADA/HMI systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelPhi-TEC I
Instrument TypeAdiabatic Accelerating Calorimeter
Measurement ModeAdiabatic Calorimetry
Temperature Range−60 °C to 500 °C
Temperature Resolution0.005 K
Temperature Accuracy (direct sample mode)±0.01 °C
Temperature Stability (isothermal mode)±0.001 °C
Heat Capacity~10,000 J/K
Sample Mass Range0.5–80 g
Pressure Range0–300 bar (optional up to 1000 bar)
Pressure Accuracy±0.05% FS
Pressure Resolution0.01 bar
Exothermic Detection Sensitivity0.005–0.2 °C/min
φ-factor (low-φ cell)≤1.05
StirringElectromagnetic, 0–500 rpm (mechanical stirrer optional)
Operating ModesHWS (Heat-Wait-Search), RAMP, ISO
External/Inner Dewar Volume10 mL each
Single-Sample Test Duration~600 min
Dimensions30 cm × 37 cm × 50 cm
Power Supply220 V AC, 13 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelChemSCAN & ChemSCAN Custom
Operating Pressure200 bar
Operating Temperature−60 °C to 200 °C
Catalyst Bed Volume120 mL
Reactor Configuration8 independently controlled parallel reactors
Standard Vessel Capacity16 mL
Optional Vessel Capacities25 mL, 50 mL, 75 mL, 120 mL, 160 mL, 300 mL, 400 mL
Stirring OptionsMagnetic suspension stirring, overhead mechanical stirring (optional), stir-controlled per reactor
Gas Consumption MonitoringReal-time, reactor-specific calculation
Liquid DosingOptional automated high-pressure liquid injection
ComplianceDesigned for GLP/GMP-aligned R&D environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelisoBTC-500
Temperature Range−60 °C to 100 °C
Temperature Resolution0.001 °C
Temperature Precision±0.01 °C
Single-Sample Test Durationup to 1000 min
Heat Capacity10,000 J/K
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Instrument TypeAccelerating Calorimeter
Measurement ModeIsothermal Calorimetry
ComplianceDesigned for GLP/GMP-aligned battery thermal safety testing
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelBioXplorer Modular Automated Benchtop Bioreactor Platform
Vessel MaterialBorosilicate Glass
Working PressureLow-Pressure (0–1 MPa vacuum range)
Nominal Volume5 L
ConfigurationModular, Supports 1–4 Parallel Vessels
Temperature Range25–60 °C
AgitationMagnetic Stirring (200–1200 rpm) or Top-Drive Mechanical Stirring (50–1500 rpm)
pH & Redox MonitoringIntegrated
Optional FeaturesIn-situ Turbidity Detection, Reaction Calorimetry, Spectral Product Tracking, Computer-Controlled Circulating Chiller
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelTSu
Instrument TypeAccelerating Rate Calorimeter (ARC®-style)
Measurement ModeAdiabatic Calorimetry
Temperature Range–60 °C to 500 °C
Temperature Resolution0.01 °C
Temperature Precision±0.01 °C
Single-Sample Test Duration~600 min
Heat Capacity~10,000 J/K
Outer Dewar Volume~10 mL
Inner Dewar Volume~10 mL
Sample Mass Range0.5–5 g
Pressure Range (standard)0–200 bar
Sample Cell8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelCAT 7 / CAT 18 / CAT 24
Max. Operating Pressure100 bar
Max. Operating Temperature300 °C
Catalyst Bed Volume10 mL
Vessel Material316 Stainless Steel or Hastelloy® Alloy
Sample Capacity Options2–10 mL per vessel
Heating MethodExternal (hotplate, oil bath, or PolyBlock™ heater block)
StirringMagnetic stirring integrated
Temperature MonitoringIntegrated micro thermocouple
Cooling OptionFinger-type condenser (CAT 7 & CAT 24 only)
HPLC Vial Compatibility2 mL vials (CAT 18 only)
Purge & PressurizationManual valve-controlled inert gas purge and reactant gas pressurization (e.g., H₂)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelSimular 10L/20L
Calorimetry ModeAdiabatic
Instrument TypeReaction Calorimeter
AutomationFully Automated
Temperature Range−30 °C to 225 °C
Temperature Resolution0.2 mK
Temperature Precision±0.1 K
Maximum Jacket Pressure100 bar
Heat Capacity Range±750 J/K
Vessel MaterialsBorosilicate Glass, 316 Stainless Steel, Hastelloy C-276
Compatible PAT InterfacesFTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelCrystalSCAN & CrystalSCAN Custom
Reactor TypeParallel Batch Crystallization Reactor
Construction MaterialStainless Steel (316 SS)
Operating PressureUp to 20 bar (High-Pressure Capable)
Working Volume Range2–500 mL
Temperature Range–80 °C to +250 °C
Number of Independent Reaction Zones4 or 8
Stirring MethodSuspended Mechanical Impeller (configurable) / Magnetic Stirring (for small vials)
Max. Viscosity Handling1000 cP
ComplianceDesigned for GLP/GMP-aligned process development environments
Software ControlIntegrated PC-based control with real-time data logging and audit trail capability
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
Modeliso-BTC+
Measurement ModeIsothermal Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC-compatible architecture)
Temperature Range−60 °C to +100 °C
Temperature Resolution0.001 °C
Temperature Precision±0.01 °C
Single-Sample Test Durationup to 1000 min
Heat Capacity10,000 J/K
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Sample Chamber Dimensions350 × 350 mm (W × D)
Maximum Compensation Power200 W
Minimum Detectable Heat Flow5 mW
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
OriginUnited Kingdom
ModelBTC-500
Instrument TypeAccelerating Rate Calorimeter (ARC)
Measurement ModeAdiabatic Calorimetry
Temperature Range−80 °C to 500 °C
Temperature Resolution0.001 K
Precision±0.01 K
Single-Sample Test DurationUp to 1000 min
Heat Capacity60,000 J
Outer Bath Volume1000 mL
Inner Bath Volume1000 mL
Adiabatic Control MethodReal-time Online PhiTEC Calibration
Sample Chamber DimensionsΦ50 × 50 cm (standard), Φ35 × 35 cm (optional)
Pressure RatingUp to 30 MPa
Data ChannelsExpandable to 8 or 16 independent temperature inputs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelCrystalEYES
Temperature Range−40 °C to 200 °C
Detection PrincipleNear-Infrared (NIR) Laser Turbidity Sensing
pH MonitoringIntegrated Auto-Logging
Data OutputCSV/Excel-Compatible Export
SoftwareReal-Time Graphical Acquisition & MSZW Analysis Module
ComplianceDesigned for GLP/GMP-Aligned Process Development Environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBlazeMetrics
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBlaze Basic Micro
PricingUpon Request
Measurement Range230 µm – 4.4 mm
Number of Optional Lenses1
Sample Dispersion MethodIn-line liquid-phase measurement / in-situ reaction system monitoring
Image Resolution PrecisionSub-nanometer (optical resolution limited by diffraction
Measured ParametersHigh-resolution micro-imaging, turbidity, chord-length-based particle size and count distribution, integrated Raman spectroscopy
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUK
ModelDigiCAT 96
Max. Reaction Pressure100 bar
Max. Reaction Temperature200 °C
Catalyst Loading Volume1 mL per vial
Throughput96 parallel reactors
Heating Block MaterialAluminum
StirringSynchronized magnetic stirring per vial
Safety Valve Setpoint~35 bar (standard configuration)
Dimensions (W×D×H)350 × 300 × 400 mm
Pressure Vessel Dimensions125 × 85 × 60 mm
Control InterfacePC-connected software with real-time monitoring and automated sequence programming
ActuationSolenoid feed & vent valves
Temperature ControlPID-regulated, sensor-integrated aluminum heating block
ComplianceDesigned to meet CE marking requirements for laboratory pressure equipment (PED 2014/68/EU applicable to < 200 bar systems under Category I)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelTandem PRO
Construction MaterialStainless Steel
Operating PressureLow-Pressure System
Vessel Capacity5 L
Vacuum Range0–1 MPa
Gas MeasurementCO₂ (IR Absorption), O₂ (Electrochemical Sensor)
CO₂ Range Options5%, 10%, 20%, 50%, 60%, 100%
O₂ Range Options25%, 30%, 50%, 60%, 100%
Resolution0.01% (both gases)
Accuracy±2% of Full Scale
Drift<0.05% FS/month
Response Time (T90)<50 s (CO₂), <10 s (O₂)
Flow Rate25–1000 mL/min
Operating Temperature0–45 °C
Temperature CompensationIntegrated
Local DisplayYes
CalibrationManual & Auto
Internal Sample PumpYes
Analog OutputsDual 0–10 V and 4–20 mA
Digital InterfaceRS232
CompatibilityScalable from lab-scale (250 mL) to industrial bioreactors (up to 100 m³)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUK
ModelSIMULAR
Instrument TypeReaction Calorimeter
Measurement ModeIsothermal Calorimeter
Temperature Range−80 to 350 °C
Temperature Resolution0.001 K
Precision±0.1%
Single-Sample Test Duration300 min
Heat Capacity10,000 J
External Water Bath Volume1000 mL
Internal Water Bath Volume1000 mL
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelBioXplorer 5000
Reactor TypeJacketed Glass Vessel
Working Volume5 L
Operating PressureLow-Pressure (0–1 MPa Vacuum Range)
Construction MaterialBorosilicate Glass (DIN/ISO Compliant)
Temperature Range25–60 °C
AgitationElectromagnetic (200–1200 rpm) or Top-Drive Mechanical (50–1500 rpm)
pH & Redox MonitoringIntegrated In-Line Sensors
Sterilization CompatibilityAutoclavable Sensors & Vessels
Parallel Operation CapacityUp to 4 × 5 L Vessels
Control ArchitectureFully Independent Channel Management
Software ModulesEntry-Level Simulation, Programmable Multi-Step Sequencing, Full Logic-Based Execution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL
OriginUnited Kingdom
ModelPolyBLOCK 4
Reactor TypeModular Parallel Reaction System
Number of Independent Reaction Zones4
Temperature Range–60 °C to +230 °C (per zone)
Max. Temperature Differential Between Zones100 °C
Vessel Capacity1 mL to 500 mL (standard), up to 1000 mL (with optional adapters)
Construction MaterialStainless Steel (316 SS)
Pressure RatingHigh-Pressure Compatible (up to 100 bar, dependent on vessel configuration)
StirringHovering Mechanical Stirring (standard), with torque and speed monitoring
Dimensions (Platform)350 × 200 × 200 mm
SoftwareWinISO v8.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelHP Simular
Measurement ModeAdiabatic Calorimetry
Instrument TypeReaction Calorimeter
AutomationFully Automated
Temperature Range−30 °C to 210 °C
Temperature Resolution0.2 mK
Temperature Precision±0.1 K
Heat Capacity Range±750 J/K
Maximum Pressure100 bar (upgradable to 200 bar)
Vessel Volume Options0.5 L, 1 L, 2 L
Vessel Materials316 Stainless Steel or Hastelloy C-276
Stirring SystemPTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch)
Pressure ReliefSwagelok 316SS PRV + dial pressure gauge
Integrated SensorsTemperature, pressure, optional in situ FTIR/Raman/turbidity/particle size
Calibration Heater150 W power-compensation heater
Control SoftwareHEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelAutoMATE High Pressure & AutoMATE Custom
Reactor TypeTubular & Batch Reactor
Working Volume10–1000 mL
Operating Pressure0–10 MPa (0–100 bar, configurable up to 200 bar)
Temperature Range−80 °C to 250 °C (oil bath), up to 500 °C with external circulator
internal heatingRT to 250 °C
Stirring OptionsMagnetic, overhead mechanical, or dual-mode
Stirring Speed0–2000 rpm (magnetic: max torque 800 N·cm
overheadmax torque 80 N·cm)
Liquid DosingHPLC-grade precision pump (0.01–50 mL/min, high-pressure)
Gas DosingMass flow controller (MFC), pressure-regulated, or volumetric metering
Solid DosingAuger feeder (350/500 mL capacity)
Interface PortsUp to 5 per reactor head (customizable) for probes (pH, FTIR, turbidity, particle size), condensers, sampling, and reagent addition
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHEL (UK)
OriginUnited Kingdom
ModelAutoLAB & AutoLAB Custom
Reactor Volume500 mL – 5 L
MaterialBorosilicate Glass (Pyrex®), Stainless Steel, Corrosion-Resistant Alloys
Operating PressureUp to 200 bar (customizable)
Configuration1–8 parallel reactors
Modular PAT IntegrationYes
SoftwareWinISO v6.x (FDA 21 CFR Part 11 compliant, audit trail enabled)
Temperature Control Range−80 °C to +250 °C (dependent on jacketed reactor & circulator)
StirringIndependent digital torque-controlled overhead stirring per reactor
Automation LevelFully programmable multi-parameter sequence control (T, P, agitation, dosing, sampling, pH, spectroscopy)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandH.E.L
ModelPAC-02
Measurement ModeAdiabatic Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC)
Temperature Range20–350 °C
Temperature Resolution0.1 °C/min
Precision≤0.1 °C
Sample Chamber Volume2015 mL
Automation LevelFully Automated
OriginFujian, China
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0