| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Phi-TEC II |
| Price Range | USD 135,000–270,000 (FOB UK) |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Temperature Accuracy (Direct Sample Mode) | ±0.001 °C |
| Temperature Tracking Rate | Up to 400 °C/min (Low-Φ mode) |
| Standard | 50 °C/min |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Tracking Rate | 0–200 bar/min (optional 700 bar/min) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Heat Release Detection Sensitivity | 0.002–0.2 °C/min |
| Sample Mass Capacity | 0.5–80 g |
| Adiabatic Correction Factor (Φ) | ≤1.05 (optimized for Phi-TEC II) |
| Outer & Inner Dewar Volume | 60 mL each |
| Thermal Capacity | 60,000 J |
| Single-Test Duration | Up to 1000 min |
| Stirring | Electromagnetic, 0–500 rpm (mechanical option available) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO (Isothermal) |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A, single-phase |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | PolyBLOCK 8 |
| Reactor Type | Modular Parallel Reaction System |
| Number of Independent Zones | 8 |
| Temperature Range | –60 °C to +230 °C (per zone) |
| Max. Inter-Zone ΔT | 100 °C |
| Vessel Compatibility | Standard and custom vessels (1–500 mL) |
| Vessel Diameter Limit | 48 mm |
| Vessel Depth Limit | 58 mm |
| Platform Dimensions | 350 × 200 × 200 mm |
| Stirring | Hovering mechanical stirrer (standard), configurable for heterogeneous systems and crystallization |
| Software | WinISO v7+ (Windows-based, FDA 21 CFR Part 11 compliant audit trail optional) |
| Data Export | Native .csv, .xlsx, and time-stamped binary formats |
| Optional Modules | Automated liquid dosing (multi-channel syringe pumps + multi-port valves), inline calorimetry (reaction heat flow), reflux & inert gas manifolds, pH/turbidity/pressure sensor integration |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | BioVIS |
| Construction Material | Stainless Steel (316L) |
| Maximum Working Pressure | 0.1 MPa (gauge) |
| Vacuum Range | 0–1 MPa (absolute) |
| Compatible Vessel Capacity | Up to 5 L |
| Sterilization | Autoclavable (121 °C, 20 min, steam) |
| Probe Length Options | Standard 100 mm, 150 mm, 200 mm, or custom-engineered lengths |
| Measurement Principle | In-situ optical backscatter at multiple wavelengths (650 nm & 850 nm) with temperature-compensated signal processing |
| Output Interface | 4–20 mA analog + RS-485 Modbus RTU |
| IP Rating | IP68 |
| Compliance | CE-marked, RoHS-compliant, compatible with ISO 13485 and FDA 21 CFR Part 11–enabled SCADA/HMI systems |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | Phi-TEC I |
| Instrument Type | Adiabatic Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −60 °C to 500 °C |
| Temperature Resolution | 0.005 K |
| Temperature Accuracy (direct sample mode) | ±0.01 °C |
| Temperature Stability (isothermal mode) | ±0.001 °C |
| Heat Capacity | ~10,000 J/K |
| Sample Mass Range | 0.5–80 g |
| Pressure Range | 0–300 bar (optional up to 1000 bar) |
| Pressure Accuracy | ±0.05% FS |
| Pressure Resolution | 0.01 bar |
| Exothermic Detection Sensitivity | 0.005–0.2 °C/min |
| φ-factor (low-φ cell) | ≤1.05 |
| Stirring | Electromagnetic, 0–500 rpm (mechanical stirrer optional) |
| Operating Modes | HWS (Heat-Wait-Search), RAMP, ISO |
| External/Inner Dewar Volume | 10 mL each |
| Single-Sample Test Duration | ~600 min |
| Dimensions | 30 cm × 37 cm × 50 cm |
| Power Supply | 220 V AC, 13 A |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | ChemSCAN & ChemSCAN Custom |
| Operating Pressure | 200 bar |
| Operating Temperature | −60 °C to 200 °C |
| Catalyst Bed Volume | 120 mL |
| Reactor Configuration | 8 independently controlled parallel reactors |
| Standard Vessel Capacity | 16 mL |
| Optional Vessel Capacities | 25 mL, 50 mL, 75 mL, 120 mL, 160 mL, 300 mL, 400 mL |
| Stirring Options | Magnetic suspension stirring, overhead mechanical stirring (optional), stir-controlled per reactor |
| Gas Consumption Monitoring | Real-time, reactor-specific calculation |
| Liquid Dosing | Optional automated high-pressure liquid injection |
| Compliance | Designed for GLP/GMP-aligned R&D environments |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | isoBTC-500 |
| Temperature Range | −60 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Isothermal Calorimetry |
| Compliance | Designed for GLP/GMP-aligned battery thermal safety testing |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | BioXplorer Modular Automated Benchtop Bioreactor Platform |
| Vessel Material | Borosilicate Glass |
| Working Pressure | Low-Pressure (0–1 MPa vacuum range) |
| Nominal Volume | 5 L |
| Configuration | Modular, Supports 1–4 Parallel Vessels |
| Temperature Range | 25–60 °C |
| Agitation | Magnetic Stirring (200–1200 rpm) or Top-Drive Mechanical Stirring (50–1500 rpm) |
| pH & Redox Monitoring | Integrated |
| Optional Features | In-situ Turbidity Detection, Reaction Calorimetry, Spectral Product Tracking, Computer-Controlled Circulating Chiller |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | TSu |
| Instrument Type | Accelerating Rate Calorimeter (ARC®-style) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | –60 °C to 500 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | ~600 min |
| Heat Capacity | ~10,000 J/K |
| Outer Dewar Volume | ~10 mL |
| Inner Dewar Volume | ~10 mL |
| Sample Mass Range | 0.5–5 g |
| Pressure Range (standard) | 0–200 bar |
| Sample Cell | 8 mL spherical vessel (material options: borosilicate glass, stainless steel, Hastelloy®, custom alloys) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CAT 7 / CAT 18 / CAT 24 |
| Max. Operating Pressure | 100 bar |
| Max. Operating Temperature | 300 °C |
| Catalyst Bed Volume | 10 mL |
| Vessel Material | 316 Stainless Steel or Hastelloy® Alloy |
| Sample Capacity Options | 2–10 mL per vessel |
| Heating Method | External (hotplate, oil bath, or PolyBlock™ heater block) |
| Stirring | Magnetic stirring integrated |
| Temperature Monitoring | Integrated micro thermocouple |
| Cooling Option | Finger-type condenser (CAT 7 & CAT 24 only) |
| HPLC Vial Compatibility | 2 mL vials (CAT 18 only) |
| Purge & Pressurization | Manual valve-controlled inert gas purge and reactant gas pressurization (e.g., H₂) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Simular 10L/20L |
| Calorimetry Mode | Adiabatic |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 225 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Maximum Jacket Pressure | 100 bar |
| Heat Capacity Range | ±750 J/K |
| Vessel Materials | Borosilicate Glass, 316 Stainless Steel, Hastelloy C-276 |
| Compatible PAT Interfaces | FTIR, Raman, pH, DO, ORP, Turbidity, Pressure, Temperature |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalSCAN & CrystalSCAN Custom |
| Reactor Type | Parallel Batch Crystallization Reactor |
| Construction Material | Stainless Steel (316 SS) |
| Operating Pressure | Up to 20 bar (High-Pressure Capable) |
| Working Volume Range | 2–500 mL |
| Temperature Range | –80 °C to +250 °C |
| Number of Independent Reaction Zones | 4 or 8 |
| Stirring Method | Suspended Mechanical Impeller (configurable) / Magnetic Stirring (for small vials) |
| Max. Viscosity Handling | 1000 cP |
| Compliance | Designed for GLP/GMP-aligned process development environments |
| Software Control | Integrated PC-based control with real-time data logging and audit trail capability |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | iso-BTC+ |
| Measurement Mode | Isothermal Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC-compatible architecture) |
| Temperature Range | −60 °C to +100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Precision | ±0.01 °C |
| Single-Sample Test Duration | up to 1000 min |
| Heat Capacity | 10,000 J/K |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Sample Chamber Dimensions | 350 × 350 mm (W × D) |
| Maximum Compensation Power | 200 W |
| Minimum Detectable Heat Flow | 5 mW |
| Brand | H.E.L |
|---|---|
| Origin | United Kingdom |
| Model | BTC-500 |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | −80 °C to 500 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.01 K |
| Single-Sample Test Duration | Up to 1000 min |
| Heat Capacity | 60,000 J |
| Outer Bath Volume | 1000 mL |
| Inner Bath Volume | 1000 mL |
| Adiabatic Control Method | Real-time Online PhiTEC Calibration |
| Sample Chamber Dimensions | Φ50 × 50 cm (standard), Φ35 × 35 cm (optional) |
| Pressure Rating | Up to 30 MPa |
| Data Channels | Expandable to 8 or 16 independent temperature inputs |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | CrystalEYES |
| Temperature Range | −40 °C to 200 °C |
| Detection Principle | Near-Infrared (NIR) Laser Turbidity Sensing |
| pH Monitoring | Integrated Auto-Logging |
| Data Output | CSV/Excel-Compatible Export |
| Software | Real-Time Graphical Acquisition & MSZW Analysis Module |
| Compliance | Designed for GLP/GMP-Aligned Process Development Environments |
| Brand | BlazeMetrics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Blaze Basic Micro |
| Pricing | Upon Request |
| Measurement Range | 230 µm – 4.4 mm |
| Number of Optional Lenses | 1 |
| Sample Dispersion Method | In-line liquid-phase measurement / in-situ reaction system monitoring |
| Image Resolution Precision | Sub-nanometer (optical resolution limited by diffraction |
| Measured Parameters | High-resolution micro-imaging, turbidity, chord-length-based particle size and count distribution, integrated Raman spectroscopy |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | DigiCAT 96 |
| Max. Reaction Pressure | 100 bar |
| Max. Reaction Temperature | 200 °C |
| Catalyst Loading Volume | 1 mL per vial |
| Throughput | 96 parallel reactors |
| Heating Block Material | Aluminum |
| Stirring | Synchronized magnetic stirring per vial |
| Safety Valve Setpoint | ~35 bar (standard configuration) |
| Dimensions (W×D×H) | 350 × 300 × 400 mm |
| Pressure Vessel Dimensions | 125 × 85 × 60 mm |
| Control Interface | PC-connected software with real-time monitoring and automated sequence programming |
| Actuation | Solenoid feed & vent valves |
| Temperature Control | PID-regulated, sensor-integrated aluminum heating block |
| Compliance | Designed to meet CE marking requirements for laboratory pressure equipment (PED 2014/68/EU applicable to < 200 bar systems under Category I) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | Tandem PRO |
| Construction Material | Stainless Steel |
| Operating Pressure | Low-Pressure System |
| Vessel Capacity | 5 L |
| Vacuum Range | 0–1 MPa |
| Gas Measurement | CO₂ (IR Absorption), O₂ (Electrochemical Sensor) |
| CO₂ Range Options | 5%, 10%, 20%, 50%, 60%, 100% |
| O₂ Range Options | 25%, 30%, 50%, 60%, 100% |
| Resolution | 0.01% (both gases) |
| Accuracy | ±2% of Full Scale |
| Drift | <0.05% FS/month |
| Response Time (T90) | <50 s (CO₂), <10 s (O₂) |
| Flow Rate | 25–1000 mL/min |
| Operating Temperature | 0–45 °C |
| Temperature Compensation | Integrated |
| Local Display | Yes |
| Calibration | Manual & Auto |
| Internal Sample Pump | Yes |
| Analog Outputs | Dual 0–10 V and 4–20 mA |
| Digital Interface | RS232 |
| Compatibility | Scalable from lab-scale (250 mL) to industrial bioreactors (up to 100 m³) |
| Brand | HEL |
|---|---|
| Origin | UK |
| Model | SIMULAR |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal Calorimeter |
| Temperature Range | −80 to 350 °C |
| Temperature Resolution | 0.001 K |
| Precision | ±0.1% |
| Single-Sample Test Duration | 300 min |
| Heat Capacity | 10,000 J |
| External Water Bath Volume | 1000 mL |
| Internal Water Bath Volume | 1000 mL |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | BioXplorer 5000 |
| Reactor Type | Jacketed Glass Vessel |
| Working Volume | 5 L |
| Operating Pressure | Low-Pressure (0–1 MPa Vacuum Range) |
| Construction Material | Borosilicate Glass (DIN/ISO Compliant) |
| Temperature Range | 25–60 °C |
| Agitation | Electromagnetic (200–1200 rpm) or Top-Drive Mechanical (50–1500 rpm) |
| pH & Redox Monitoring | Integrated In-Line Sensors |
| Sterilization Compatibility | Autoclavable Sensors & Vessels |
| Parallel Operation Capacity | Up to 4 × 5 L Vessels |
| Control Architecture | Fully Independent Channel Management |
| Software Modules | Entry-Level Simulation, Programmable Multi-Step Sequencing, Full Logic-Based Execution |
| Brand | HEL |
|---|---|
| Origin | United Kingdom |
| Model | PolyBLOCK 4 |
| Reactor Type | Modular Parallel Reaction System |
| Number of Independent Reaction Zones | 4 |
| Temperature Range | –60 °C to +230 °C (per zone) |
| Max. Temperature Differential Between Zones | 100 °C |
| Vessel Capacity | 1 mL to 500 mL (standard), up to 1000 mL (with optional adapters) |
| Construction Material | Stainless Steel (316 SS) |
| Pressure Rating | High-Pressure Compatible (up to 100 bar, dependent on vessel configuration) |
| Stirring | Hovering Mechanical Stirring (standard), with torque and speed monitoring |
| Dimensions (Platform) | 350 × 200 × 200 mm |
| Software | WinISO v8.x (Windows-based, FDA 21 CFR Part 11 compliant audit trail option) |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | HP Simular |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Automation | Fully Automated |
| Temperature Range | −30 °C to 210 °C |
| Temperature Resolution | 0.2 mK |
| Temperature Precision | ±0.1 K |
| Heat Capacity Range | ±750 J/K |
| Maximum Pressure | 100 bar (upgradable to 200 bar) |
| Vessel Volume Options | 0.5 L, 1 L, 2 L |
| Vessel Materials | 316 Stainless Steel or Hastelloy C-276 |
| Stirring System | PTFE-coated shaft with 4-blade PTFE impeller (45–60° pitch) |
| Pressure Relief | Swagelok 316SS PRV + dial pressure gauge |
| Integrated Sensors | Temperature, pressure, optional in situ FTIR/Raman/turbidity/particle size |
| Calibration Heater | 150 W power-compensation heater |
| Control Software | HEL ChemScan™ with PAT integration, audit trail, and 21 CFR Part 11 compliance support |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoMATE High Pressure & AutoMATE Custom |
| Reactor Type | Tubular & Batch Reactor |
| Working Volume | 10–1000 mL |
| Operating Pressure | 0–10 MPa (0–100 bar, configurable up to 200 bar) |
| Temperature Range | −80 °C to 250 °C (oil bath), up to 500 °C with external circulator |
| internal heating | RT to 250 °C |
| Stirring Options | Magnetic, overhead mechanical, or dual-mode |
| Stirring Speed | 0–2000 rpm (magnetic: max torque 800 N·cm |
| overhead | max torque 80 N·cm) |
| Liquid Dosing | HPLC-grade precision pump (0.01–50 mL/min, high-pressure) |
| Gas Dosing | Mass flow controller (MFC), pressure-regulated, or volumetric metering |
| Solid Dosing | Auger feeder (350/500 mL capacity) |
| Interface Ports | Up to 5 per reactor head (customizable) for probes (pH, FTIR, turbidity, particle size), condensers, sampling, and reagent addition |
| Compliance | Designed for GLP/GMP environments |
| Brand | HEL (UK) |
|---|---|
| Origin | United Kingdom |
| Model | AutoLAB & AutoLAB Custom |
| Reactor Volume | 500 mL – 5 L |
| Material | Borosilicate Glass (Pyrex®), Stainless Steel, Corrosion-Resistant Alloys |
| Operating Pressure | Up to 200 bar (customizable) |
| Configuration | 1–8 parallel reactors |
| Modular PAT Integration | Yes |
| Software | WinISO v6.x (FDA 21 CFR Part 11 compliant, audit trail enabled) |
| Temperature Control Range | −80 °C to +250 °C (dependent on jacketed reactor & circulator) |
| Stirring | Independent digital torque-controlled overhead stirring per reactor |
| Automation Level | Fully programmable multi-parameter sequence control (T, P, agitation, dosing, sampling, pH, spectroscopy) |
| Brand | H.E.L |
|---|---|
| Model | PAC-02 |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | 20–350 °C |
| Temperature Resolution | 0.1 °C/min |
| Precision | ≤0.1 °C |
| Sample Chamber Volume | 2015 mL |
| Automation Level | Fully Automated |
| Origin | Fujian, China |