Empowering Scientific Discovery

Thermal Desorption Tube Activator HL-TDA10

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Hailong
Temperature Range 50–380 °C
Temperature Accuracy ±1 °C
Gas Flow Rate 10–1000 mL/min
Activation Duration Up to 99 h 99 min 99 s
Compatible Tube OD 6–6.5 mm
Tube Materials Stainless Steel, Quartz, Borosilicate Glass
Compatible Sorbents Tenax TA, Carbograph, Activated Carbon
Input Power 220 V ±10%, 50–60 Hz

Overview

The Hailong HL-TDA10 Thermal Desorption Tube Activator is an engineered benchtop system designed for the precise thermal conditioning of sorbent-packed sampling tubes prior to analytical use in volatile organic compound (VOC) and semi-volatile organic compound (SVOC) monitoring workflows. Based on controlled inert-gas purging under programmable temperature ramping and isothermal hold profiles, the HL-TDA10 removes residual contaminants—including moisture, plasticizers, phthalates, and native volatiles—from sorbent beds (e.g., Tenax TA, Carbograph 1TD, and activated carbon) without thermal degradation or channeling. This activation process is critical to achieving low method blanks, high recovery reproducibility (>95% for C2–C12 alkanes), and compliance with EPA Method TO-17, ISO 16017-1, and ASTM D6196 requirements for ambient, indoor, and occupational air sampling.

Key Features

  • Programmable dual-stage thermal protocol: independent ramp rate control (0.1–20 °C/min) followed by user-defined isothermal hold (up to 99 h 99 min 99 s) ensures complete desorption of trace-level interferences.
  • Uniform axial heating architecture with PID-controlled zone distribution maintains ±1 °C spatial temperature stability across all tube positions—verified per ASTM E220 calibration standards.
  • Dual-mode gas delivery: digitally regulated mass flow controller (MFC) supports inert purge (N2, He, or Ar) at 10–1000 mL/min with real-time flow feedback and overpressure protection.
  • Intuitive 4.3-inch TFT LCD interface with multilingual menu navigation (English, Spanish, German), event logging, and password-protected parameter locking for GLP-compliant operation.
  • Modular tube holder accommodates 1–10 standard 6–6.5 mm OD tubes simultaneously—compatible with stainless steel, fused quartz, and borosilicate glass substrates—without tooling or alignment fixtures.
  • Integrated post-activation cooling cycle: forced-air heat dissipation reduces tube surface temperature to <40 °C within ≤15 min after program completion, enabling safe handling and immediate capping under laminar flow.

Sample Compatibility & Compliance

The HL-TDA10 supports industry-standard sorbent tubes used in thermal desorption–gas chromatography–mass spectrometry (TD-GC-MS) and TD-GC-FID analysis. Verified compatibility includes 3.5 in. × ¼ in. OD stainless steel tubes packed with Tenax TA (60/80 mesh), Carbograph 4, Carbopack X, and coconut-shell-based activated carbon. The system meets mechanical and thermal performance criteria outlined in ISO/IEC 17025:2017 for laboratory equipment qualification and supports audit-ready documentation for FDA 21 CFR Part 11–compliant environments when paired with validated LIMS integration.

Software & Data Management

While the HL-TDA10 operates as a standalone instrument, its embedded firmware records full activation logs—including setpoint history, actual temperature profile, flow rate trace, and start/stop timestamps—with automatic UTC stamping and non-volatile memory retention (≥10,000 cycles). Optional RS-232 or USB-C interface enables export of CSV-formatted logs for traceability in QA/QC review. Firmware updates are delivered via encrypted .bin files and verified using SHA-256 checksum validation—ensuring integrity during regulatory audits.

Applications

  • Pre-conditioning of sorbent tubes for EPA TO-11A, TO-15, and TO-17 compliant air sampling in environmental laboratories.
  • Blank reduction in occupational hygiene monitoring where sub-ppbv detection limits are required (e.g., OSHA ID-255, NIOSH 1501).
  • Method development support for multi-sorbent tube configurations (e.g., layered Tenax–Carbograph–Carbon) requiring differential activation protocols.
  • Quality assurance in certified reference material (CRM) production labs performing ISO Guide 34–accredited tube certification.
  • Routine maintenance of in-house tube inventories in high-throughput GC-MS facilities processing >500 tubes/week.

FAQ

What inert gases are compatible with the HL-TDA10?
Nitrogen (grade 5.0 or higher), helium, and argon are supported. Gas purity must be ≥99.999% to prevent oxide formation on metal tube surfaces.
Can the HL-TDA10 activate tubes containing mixed-bed sorbents?
Yes—provided the lowest thermal stability limit of any sorbent layer is respected. Example: For a Tenax–Carbograph–Charcoal tri-bed, maximum activation temperature should not exceed 320 °C.
Is external cooling water required?
No. The unit uses passive convection and active fan-assisted air cooling; no plumbing or chiller integration is needed.
How is temperature calibration verified?
Users may perform in-situ verification using a NIST-traceable Class A Pt100 probe inserted into a dummy tube positioned at the geometric center of the heating zone.
Does the HL-TDA10 support remote monitoring or network connectivity?
Not natively—but optional OEM firmware extension modules (sold separately) provide Modbus RTU over RS-485 for SCADA integration in centralized lab automation systems.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0