Empowering Scientific Discovery

GreenPrima PM8202P Online pH Meter for Drinking Water Applications

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand GreenPrima
Origin United Kingdom
Manufacturer Type Direct Manufacturer
Product Origin Imported
Model PM8202P
Measurement Range -2 to 16 pH, -2000 to +2000 mV, 0 to 130 °C
Resolution 0.01 pH, 1 mV, 0.1 °C
Accuracy ±0.01 pH, ±0.1 mV, ±0.1 °C
Temperature Compensation Range -10 to 130 °C (Manual/Automatic
Dimensions 144 × 144 × 108 mm
Weight 0.87 kg

Overview

The GreenPrima PM8202P Online pH Meter is an industrial-grade, microprocessor-based process analyzer engineered for continuous, high-stability monitoring of pH and redox potential (ORP) in potable water distribution systems, municipal treatment plants, and regulated water reuse applications. Operating on the principle of potentiometric measurement via a glass electrode and reference junction, the instrument delivers real-time electrochemical data with traceable calibration integrity. Its dual-channel capability supports simultaneous pH and temperature measurement, with automatic temperature compensation (ATC) using either NTC10K or PT1000 sensors—ensuring thermally robust performance across dynamic thermal gradients typical of chlorinated drinking water streams, storage reservoirs, and post-filtration lines. Designed to meet the operational rigor of 24/7 utility environments, the PM8202P complies with functional safety expectations for Class I, Division 2 hazardous locations and integrates seamlessly into SCADA and DCS architectures via standardized analog and digital interfaces.

Key Features

  • IP65-rated, fully sealed enclosure with corrosion-resistant polycarbonate housing—rated for outdoor wall-mount, pipe-mount, or panel-mount deployment in humid, chemically aggressive environments
  • Backlit high-contrast dot-matrix LCD display showing real-time pH/ORP values, temperature, timestamp, relay status, and system diagnostics
  • Configurable dual isolated 4–20 mA outputs (0.1% FS accuracy, max 500 Ω loop resistance) assignable to pH, ORP, or temperature signals independently
  • RS485 Modbus RTU communication protocol (slave mode) enabling bidirectional data exchange with PLCs, HMIs, and centralized data historians
  • User-accessible password protection (three-tier access levels), factory reset function, and configurable alarm hysteresis for reliable operational governance
  • Integrated cleaning control output with programmable cycle duration (1–1000 s) and interval (0.1–1000 h), supporting solenoid-driven chemical or air-pulse cleaning systems
  • Two independent relay outputs (5 A / 250 VAC / 30 VDC) with high/low setpoints, fault logging, and visual status indication
  • Onboard non-volatile memory storing up to 600,000 timestamped measurement records—retaining historical trends for regulatory review and process optimization

Sample Compatibility & Compliance

The PM8202P is optimized for low-conductivity aqueous matrices typical of treated drinking water (typically 50–500 µS/cm), where stable junction potential and minimal liquid junction drift are critical. It supports interchangeable GreenPrima Bsens-series pH electrodes—including the Bsens110T (general-purpose gel-filled), Bsens120T (low-maintenance refillable), and Bsens180T (high-temperature, pressurized line variant)—all featuring double-junction reference systems and ceramic frits engineered to resist clogging from calcium carbonate scaling or chlorine-induced silver chloride precipitation. The system conforms to ISO 7888 (water quality — determination of pH), ASTM D1293 (Standard Test Methods for pH of Water), and supports audit-ready operation under GLP and GMP frameworks through timestamped calibration logs, user action tracking, and secure parameter locking. Optional firmware upgrades enable compliance with FDA 21 CFR Part 11 requirements for electronic records and signatures when paired with validated data management software.

Software & Data Management

Data acquisition and configuration are managed via intuitive front-panel navigation with bilingual (English/Chinese) menu structure—requiring no external PC for routine operation. For advanced analytics, GreenPrima’s optional PC-based configuration utility (GreenPrima ConfigTool v3.2+) enables remote parameter setup, firmware updates, trend export (CSV/Excel), and alarm event filtering. All stored measurements include UTC timestamps, sensor ID, calibration history, and environmental metadata—facilitating traceability during regulatory audits. The device maintains internal clock synchronization via NTP-compatible gateways when integrated into enterprise networks, ensuring temporal consistency across distributed sensor nodes in multi-point water quality monitoring networks.

Applications

  • Real-time pH monitoring at drinking water treatment plant effluent points and distribution network entry stations
  • Continuous ORP surveillance in chlorine/chloramine disinfection contact tanks and clearwells
  • Process control in membrane filtration systems (e.g., RO feed and permeate streams)
  • Regulatory compliance reporting for EPA Safe Drinking Water Act (SDWA) Section 1413 and EU Directive 98/83/EC
  • Early detection of corrosion-related pH excursions in aging cast-iron or ductile iron distribution mains
  • Integration into smart water grid initiatives requiring edge-level data preprocessing and alarm forwarding via MQTT or OPC UA protocols

FAQ

What electrode types are compatible with the PM8202P controller?

The PM8202P is designed exclusively for GreenPrima Bsens-series pH sensors, including Bsens110T, Bsens210, Bsens120T, Bsens130, Bsens140T, Bsens150T, and Bsens180T—all featuring standardized BNC or DIN connectors and auto-sensing electrode identification.
Does the PM8202P support automatic temperature compensation with third-party RTDs?

Yes—it accepts standard NTC10K (β = 3950 K) and PT1000 resistance temperature detectors; custom RTD curves may be configured via the ConfigTool software.
Can the data logger be accessed remotely without physical connection?

Remote readout is supported via Modbus RTU over RS485; full data export and configuration require GreenPrima ConfigTool connected via USB-to-RS485 adapter or Ethernet gateway.
Is the unit certified for use in explosion-hazardous areas?

The PM8202P itself carries IP65 ingress protection and operates within Class I, Division 2 environmental limits; intrinsic safety certification requires integration with approved barrier systems per IECEx/ATEX standards.
How often does the system require calibration verification in drinking water applications?

Per ISO 5725 and US EPA Method 150.1, daily zero/span checks are recommended for critical compliance points; full two-point calibration every 7–14 days is typical for stable municipal water matrices with automated cleaning cycles enabled.