Empowering Scientific Discovery

PULUODY China Service Center / PULUODY Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-510C
OriginShaanxi, China
Manufacturer TypeOEM Manufacturer
Country of OriginChina
Temperature Range60 °C to −38 °C
Temperature Resolution0.1 °C
Sample Channels2
Detection MethodTop-mounted photoelectric liquid-level sensor with automated sample tube tilting
Cooling SystemMechanical compressor-based refrigeration
Cooling MediumAir-cooled condenser
Temperature Differential ControlProgrammable ΔT between coolant and sample
Tilt MechanismMicro-tilt actuation with real-time liquid-level feedback
Heating ElementIntegrated micro-heater for rapid sample recovery
Display128×64 dot-matrix LCD (Chinese character support)
Printer20-column thermal dot-matrix printer (Chinese character support)
Power SupplyAC 220 V ±10%, 50 Hz ±2 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Regional CategoryDomestic
ModelPLD-0201
Instrument TypeOptical Particle Counter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2A
Instrument TypeOptical Particle Counter
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Detection Range0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c))
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Flow ControlPrecision Plunger Pump + Electromagnetic Flow Regulation
Compliance StandardsUSP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061
Data Output4–20 mA analog interface, iPad-compatible wireless acquisition
ReportingParticles per mL & ISO 4406 / NAS 1638 contamination codes
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelPMT-2-13
Instrument TypeOptical Liquid Particle Counter
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Calibration StandardsJJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres
Detection Range0.1–0.5 µm & 0.2–2.0 µm (standard)
Sampling MethodPrecision Metering Piston Pump
Flow ControlDual-stage electromagnetic + mechanical precision regulation
Sample Volume Accuracy< ±1%
Counting Accuracy±5% typical (NIST-traceable validation)
Coincidence Limit≤5% error at 10,000 particles/mL
Output Interface4–20 mA analog output
Alarm FunctionConfigurable particle concentration threshold alert
ReportingParticles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen UI)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelPLD-MPCS2.0-B
PriceUSD 53,800 (approx.)
Microscope ConfigurationUpright
Integrated Image Analysis SystemYes
Total Magnification Range40× to 1000×
Eyepiece10×
Objective Lenses10× (standard), with optional 4×, 20×, 40×, 100× oil immersion
Camera Resolution3 MP CCD
Optical Resolution0.1 µm
Measurement Accuracy±3% (typical)
Repeatability Error<5% (excluding sample preparation variability)
Particle Detection Resolution>95% (calibrated per ChP 2020)
Coincidence Limit10,000 particles/mL (5% coincidence error)
Image Segmentation Speed<1 sec per frame
Segmentation Success Rate>93%
Calibration ValidationCertified by Northwest National Metrology & Testing Center (Civil Products)
Software CompatibilityWindows 2000/XP (legacy support)
Analytical OutputsParticle size distribution (1–500 µm), aspect ratio distribution, circularity distribution, particle count per volume, length-weighted mean diameter, projected area equivalent diameter
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Instrument TypeOptical Particle Counter
Laser Sensor Generation7th-generation dual-laser narrow-beam detector
Measurement PrincipleLight Blockage (LO) & Light Scattering (LS)
Calibration StandardsISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061
ComplianceISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500
Particle Size Range0.03 µm – 3000 µm (configurable sensor modules)
Channel CountUp to 1000 resolution channels
Sensitivity1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854)
Coincidence Limit≤5% at 10,000 particles/mL
Resolution≥90% @ 60 mL/min
Volumetric Accuracy±1%
Flow Rate (Sampling)5–60 mL/min
Flow Rate (Cleaning)5–150 mL/min
Max. Online Pressure0–31.5 MPa (with pressure regulator)
Viscosity RangeOffline ≤99 mm²/s
Operating TemperatureAmbient to 65°C
Power Supply220 VAC, 50 Hz, <80 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2
OriginShaanxi, China
Sensor8th-Generation Dual-Laser Narrow-Beam Detector
Detection Range0.1–1.0 µm & 0.1–0.5 µm
Customizable Range1–100 µm or 4–70 µm (c), down to 0.1 µm (c)
Sampling Accuracy<±1%
Measurement Accuracy<±3% (typical)
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Output4–20 mA analog interface with configurable超标 alarm
ComplianceChinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368, JJG 1061, ISO 21501-4
SoftwareV8.3 Integrated Analysis & Calibration Software (PC + Touchscreen UI)
Power Input100–265 VAC, 50–60 Hz
DisplayColor LCD touchscreen + optional wireless keyboard/mouse
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPLD-0201L
Measurement PrincipleLight Obscuration (LO) / Optical Blockage
Detection Range1 µm to 450 µm
Sensitivity1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854)
Channel Configuration8 user-definable size channels
Counting Accuracy≤5% coincidence error at 10,000 particles/mL
Sample Volume Accuracy±1%
Flow ControlPrecision piston pump with electromagnetic flow regulation (5–60 mL/min)
Pressure Range−0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment)
Viscosity Limit≤350 cSt (mm²/s)
Operating TemperatureAmbient to 65 °C
Environmental Temp.0–50 °C
Power Supply220 V AC, 50 Hz, <80 W
Compliance StandardsISO 4406:1999, NAS 1638, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95, GJB 380, GJB 420
Data InterfaceRS232 serial port
Built-in PrinterYes
Calibration TraceabilityCertified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPST-890
PriceUSD 53,200 (approx. ¥380,000)
Sensor Generation8th-Gen Dual-Laser Narrow-Beam Detector
Detection PrincipleLight Obscuration (LO) / Single-Particle Optical Sizing (SPOS)
Calibration StandardsISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres
SoftwareV8.9 Integrated Particle Analysis Suite (PC & Embedded Touch UI)
Sample Flow Rate5–150 mL/min
Rinse Flow Rate5–500 mL/min
Temperature Range (Fluid)0–80 °C
Environmental Operating Range−15–50 °C
Counting Channels1000 configurable channels (user-definable from 4 to 128 size bins)
Detection Range1–450 µm (extended range 0.03–3000 µm optional)
Custom Ranges1–100 µm, 4–70 µm(c), 0.1 µm(c)
Sampling Accuracy<±1%
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Resolution>95% (per ChP 2015/2020), <10% (per USP <788>, ISO 21501-4)
ComplianceGB/T 11446.9–2013, ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, IP 2015, WHO IntPh IV, YBB 00272004–2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, SAE AS4059, MIL-STD-1246C, JIS B 9933, IP 564/565, ROC T 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GJB/T 420A/B, GB/T 18854
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Instrument TypeOptical Particle Counter (Light Obscuration Principle)
ModelPLD-0201I
Measurement PrincipleLight Obscuration (LO) per ISO 11171:1999 / ISO 4406:1999 / NAS1638 / GJB420B
Laser Sensor7th-Generation Narrow-Beam Laser Detector (PCF-7A)
Measurement Range1–450 µm
Sensitivity1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854)
Channels8 user-configurable size thresholds
Sample Volume Accuracy±1%
Flow Rate Control5–60 mL/min via precision piston pump with electromagnetic flow regulation
Pressure Range–0.06 to 0.7 MPa (dual positive/negative pressure pre-treatment system)
Viscosity Handlingup to 350 cSt
Max Particle Concentration10,000 particles/mL (≤5% coincidence error)
Test DurationAdjustable, default 12.5 s
Operating TempAmbient to 65 °C
Ambient Temp0–50 °C
Power220 V AC, 50 Hz, <80 W
Calibration ComplianceGB/T 18854–2002, ISO 11171:1999, JJG 066–95
Data OutputReal-time particle count/size distribution, histogram, ISO 4406 & NAS1638 contamination grade assignment, built-in thermal printer
InterfaceRS232 serial port
SoftwareP6.4 Analysis Suite (integrated LabPC7 platform)
Regulatory SupportGLP-compliant audit trail, FDA 21 CFR Part 11-ready configuration (optional), traceable calibration certificate available from National Defense Science & Technology Industry First-Class Particle Metrology Station (No. 116)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2GT
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Detection Range0.5–20.0 µm (standard), customizable to 1–100 µm or 4–70 µm(c)
Resolution0.1 µm(c) minimum detectable threshold
Sampling Accuracy<±1%
Measurement Accuracy<±3% (typical)
Coincidence Limit≤2.5% at 1000 particles/mL
Output4–20 mA analog signal with configurable alarm triggers
Calibration StandardsJJG 1061, ISO 21501-2, NIST-traceable latex sphere reference materials
SoftwareV8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI)
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPST-890
Detection PrincipleLight Obscuration (LO) with Dual-Laser Narrow-Beam Sensor
Particle Size Range1–450 µm (optional extended to 0.03–3000 µm)
Resolution>95% (ChP 2015/2020 calibrated), <10% (USP/ISO 21501 calibrated)
Channel Count1000 adjustable channels (customizable from 4 to 128 size bins)
Flow ControlPrecision metering piston pump + ultra-precise electromagnetic flow regulation
Sampling Accuracy<±1%
Counting Accuracy±3% typical
Coincidence Limit≤2.5% error at 1000 particles/mL
Operating TemperatureFluid 0–80 °C, Ambient –15–50 °C
ComplianceUSP <788>, <789>, <797>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPMT-2-T
Instrument TypeOptical Particle Counter
Detection PrincipleDual-Laser Narrow-Beam Light Scattering
Detection Range0.1–1.0 µm & 0.1–0.5 µm (standard)
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368
Flow ControlPrecision Piston Pump + Electromagnetic Flow Regulation
Sampling Accuracy< ±1%
Counting Accuracy< ±3% (typical)
Coincidence Limit1000 particles/mL (2.5% coincidence error)
Output Interface4–20 mA analog output with configurable alarm threshold
Data ReportingParticles per mL and ISO 4406 / NAS 1638 contamination grade
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen Edition)
Compliance SupportFDA 21 CFR Part 11 audit trail ready (with optional configuration), GLP/GMP traceable operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelOPC-2300M
PriceUSD 13,800 (FOB)
Detection PrincipleLight Obscuration (LO) with Dual-Laser Narrow-Beam Technology
Sensor Generation8th-Generation
Measuring Range2–750 µm (configurable up to 1000 µm)
Size Channels1000-user-definable channels, standard presets: 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm
Resolution0.1 µm
Resolution Accuracy±10% (per ISO 21501-4)
Counting Accuracy<±3% typical (NIST-traceable calibration)
Coincidence Error≤5% at 9,999 particles/mL
Maximum Detectable Concentration9,999,999 particles/mL
Sampling Interval5 s – 9 h (programmable)
Flow Rate6–500 mL/min
Operating Pressure0–0.6 MPa (standard), 0–31.5 MPa (with optional pressure regulator)
Fluid Temperature Range−10 °C to +80 °C
Calibration StandardsNIST-traceable polystyrene latex (PSL) spheres, AC fine test dust, MTD
Output Interfaces4–20 mA analog, RS232, RS485
Data StorageInternal non-volatile memory + external USB/SD logging
DisplayBacklit LCD with membrane keypad
Enclosure RatingIP65 (optional IP67)
Power Supply9–30 VDC or 220 VAC
Alarm FunctionsParticle count threshold, sensor fault, flow interruption, temperature/pressure out-of-range
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPLULODY/PULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelPLD Series
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelPS8011+
Price RangeUSD 135 – 525
Material OptionsPP, PE, PFA, PEEK, PFAD, High-Silica Borosilicate Glass
Volume Options50 mL to 1000 mL
Particle Cleanliness LevelRCL < 15 particles per 100 mL
Certified Cleanliness ClassesISO Class 1–9 (per ISO 14644-1)
Particle Detection Thresholds0.1 µm, 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm
Average Outgoing Quality Limit (AOQL)0.5%
Compliance StandardsISO 3722, ISO 14644-1, GB/T 17484, GB 50073-2001, JIS B9925:1997, JIS K0554:1995
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelPLD-268A
Ceramic CrucibleLow-form, 30 mL
Inner Iron CrucibleGalvanized steel, 75 ± 5 mL with lid
Outer Iron CrucibleGalvanized steel, 190 ± 10 mL with lid
Tripod StandStainless steel, height 250 ± 10 mm, ring diameter Φ130 ± 5 mm
Flame ShieldStainless steel, conical bore—top opening Φ90 ± 2 mm, bottom opening Φ82 ± 2 mm
Stainless Steel CoverLower cylindrical section height 50–53 mm
Gas BurnerMetric-pattern gas blowtorch (Conradson-type)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2LD
Instrument TypeOptical Particle Counter
Detection PrincipleDual-Laser Narrow-Beam Light Obscuration
Detection Range0.5–20.0 µm (standard)
Sensor Generation8th-Generation Dual-Laser Narrow-Beam Detector
Sampling MethodPrecision Metering Piston Pump
Flow ControlDual-Stage Electromagnetic + Precision Piston Pump
Accuracy±3% typical
Volume Accuracy±1%
Coincidence Limit≤2.5% error at 1000 particles/mL
Output4–20 mA analog interface with configurable particle concentration alarm
Calibration StandardsJJG 1061, ISO 21501-4, NIST-traceable latex sphere reference
SoftwareV8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI)
DisplayColor LCD touchscreen + optional wireless keyboard/mouse
Power Input100–265 VAC, 50–60 Hz
ComplianceDesigned for GLP/GMP-aligned environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPS3200-6L
Capacity6 L
Ultrasonic Frequency53 kHz
Ultrasonic Power≥200 W
Power AdjustmentYes (40–100%, 1% stepwise)
Temperature Control Range20–60 °C
Heating Power150 W
Timer Range1–199 min
Tank Dimensions30 × 15 × 15 cm
Overall Dimensions33 × 18 × 29 cm
Power Supply220 V / 50 Hz
Noise Reduction LidIncluded
Manual Drain ValveYes
Construction304 Stainless Steel Tank & Argon-Welded Mesh Basket
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeManufacturer
Product CategoryDomestic Instrument
ModelCLDEE-CCACS2.0
PriceUSD 5,150 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
ModelPLD-601XY
Instrument TypeOptical Particle Counter (Light Obscuration Principle)
Detection Range1–450 µm (optional extended range: 0.03–3000 µm)
Channel Count1000 customizable size channels (down to 0.01 µm resolution)
Flow ControlDual-precision metering piston pump + ultra-precise electromagnetic flow control system
ComplianceUSP <788>, <789>, <797>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelPMT-2801
Detection PrincipleDual-laser light scattering (narrow-beam, 8th-generation)
Particle Size Range0.1–0.5 µm (standard)
Accuracy±3% typical
Sampling Precision<±1%
Coincidence Limit≤2.5% at 1000 particles/mL
Flow ControlPrecision piston pump + electromagnetic flow regulation
ComplianceUSP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061
Data Output4–20 mA analog interface
Power Input100–265 VAC, 50–60 Hz
SoftwarePULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI)
Operating InterfaceColor LCD touch screen + optional wireless keyboard/mouse
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelPMT-2-H
PriceUSD 72,800 (approx.)
Dispersion MethodWet Dispersion
Instrument TypeLaboratory Laser-Based Particle Counter
Measurement Range0.5–5.0 µm
Repeatability≤3% RSD
Measurement Time60 s per sample
Sensor Generation8th-Generation Dual-Laser Narrow-Beam Detection
Calibration StandardsISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368
Flow ControlPrecision Metering Plunger Pump + Ultra-Stable Electromagnetic Flow Regulation
Sample Interface4–20 mA Analog Output
Data AcquisitioniPad-Compatible Wireless Interface
Operating InterfaceColor LCD Touchscreen + Optional Wireless Keyboard/Mouse
Reporting UnitsParticles/mL & ISO 4406 / NAS 1638 Contamination Codes
Voltage Input100–265 VAC, 50–60 Hz
Counting Accuracy<±1% volumetric error
coincidence limit1000 particles/mL (≤2.5% coincidence error)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPULUODY
ModelOPC
OriginShaanxi, China
Detection PrincipleLight Obscuration (LO) with Dual-Laser Narrow-Beam Technology
Measurement Range1–150 µm
Calibration Standards SupportedISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854
Operating Pressure0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator)
Sample Flow Rate6–500 mL/min
Fluid Temperature Range−10 °C to +80 °C
Viscosity Limit≤500 cSt (online mode)
Output Interfaces4–20 mA analog, RS232 serial, optional alarm relay
Power Supply9–30 VDC
ComplianceDesigned for industrial process monitoring per ISO 21501-4, ASTM D6786, and IEC 61508 SIL2-ready architecture
Enclosure RatingIP65 (standard), optional IP67
SoftwareIntegrated firmware with configurable reporting (particles/mL + contamination code)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0