| Brand | PULUODY |
|---|---|
| Model | PLD-510C |
| Origin | Shaanxi, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Temperature Range | 60 °C to −38 °C |
| Temperature Resolution | 0.1 °C |
| Sample Channels | 2 |
| Detection Method | Top-mounted photoelectric liquid-level sensor with automated sample tube tilting |
| Cooling System | Mechanical compressor-based refrigeration |
| Cooling Medium | Air-cooled condenser |
| Temperature Differential Control | Programmable ΔT between coolant and sample |
| Tilt Mechanism | Micro-tilt actuation with real-time liquid-level feedback |
| Heating Element | Integrated micro-heater for rapid sample recovery |
| Display | 128×64 dot-matrix LCD (Chinese character support) |
| Printer | 20-column thermal dot-matrix printer (Chinese character support) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Category | Domestic |
| Model | PLD-0201 |
| Instrument Type | Optical Particle Counter |
| Brand | PULUODY |
|---|---|
| Model | PMT-2A |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–100 µm (customizable sub-ranges: 0.1 µm(c), 4–70 µm(c)) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Flow Control | Precision Plunger Pump + Electromagnetic Flow Regulation |
| Compliance Standards | USP <788>, USP <789>, EP 2.9.19, BP 2.9.19, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface, iPad-compatible wireless acquisition |
| Reporting | Particles per mL & ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-13 |
| Instrument Type | Optical Liquid Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Calibration Standards | JJG 1061, ISO 21501-2, Polystyrene Latex (PSL) Reference Spheres |
| Detection Range | 0.1–0.5 µm & 0.2–2.0 µm (standard) |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-stage electromagnetic + mechanical precision regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±5% typical (NIST-traceable validation) |
| Coincidence Limit | ≤5% error at 10,000 particles/mL |
| Output Interface | 4–20 mA analog output |
| Alarm Function | Configurable particle concentration threshold alert |
| Reporting | Particles per mL + ISO 4406 / NAS 1638 / SAE AS4059 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + embedded touchscreen UI) |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PLD-MPCS2.0-B |
| Price | USD 53,800 (approx.) |
| Microscope Configuration | Upright |
| Integrated Image Analysis System | Yes |
| Total Magnification Range | 40× to 1000× |
| Eyepiece | 10× |
| Objective Lenses | 10× (standard), with optional 4×, 20×, 40×, 100× oil immersion |
| Camera Resolution | 3 MP CCD |
| Optical Resolution | 0.1 µm |
| Measurement Accuracy | ±3% (typical) |
| Repeatability Error | <5% (excluding sample preparation variability) |
| Particle Detection Resolution | >95% (calibrated per ChP 2020) |
| Coincidence Limit | 10,000 particles/mL (5% coincidence error) |
| Image Segmentation Speed | <1 sec per frame |
| Segmentation Success Rate | >93% |
| Calibration Validation | Certified by Northwest National Metrology & Testing Center (Civil Products) |
| Software Compatibility | Windows 2000/XP (legacy support) |
| Analytical Outputs | Particle size distribution (1–500 µm), aspect ratio distribution, circularity distribution, particle count per volume, length-weighted mean diameter, projected area equivalent diameter |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Instrument Type | Optical Particle Counter |
| Laser Sensor Generation | 7th-generation dual-laser narrow-beam detector |
| Measurement Principle | Light Blockage (LO) & Light Scattering (LS) |
| Calibration Standards | ISO 11171, ISO 4402, ASTM F658-87 (PSL), GB/T 18854, JJG 1061 |
| Compliance | ISO 4406:1999/2017, NAS 1638, SAE AS4059F, GJB 420B, DL/T 432, GJB 380, ISO 11500 |
| Particle Size Range | 0.03 µm – 3000 µm (configurable sensor modules) |
| Channel Count | Up to 1000 resolution channels |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 / GB/T 18854) |
| Coincidence Limit | ≤5% at 10,000 particles/mL |
| Resolution | ≥90% @ 60 mL/min |
| Volumetric Accuracy | ±1% |
| Flow Rate (Sampling) | 5–60 mL/min |
| Flow Rate (Cleaning) | 5–150 mL/min |
| Max. Online Pressure | 0–31.5 MPa (with pressure regulator) |
| Viscosity Range | Offline ≤99 mm²/s |
| Operating Temperature | Ambient to 65°C |
| Power Supply | 220 VAC, 50 Hz, <80 W |
| Brand | PULUODY |
|---|---|
| Model | PMT-2 |
| Origin | Shaanxi, China |
| Sensor | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm |
| Customizable Range | 1–100 µm or 4–70 µm (c), down to 0.1 µm (c) |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output | 4–20 mA analog interface with configurable超标 alarm |
| Compliance | Chinese Pharmacopoeia 2015/2020, USP <788>, EP 2.9.19, BP, GB 8368, JJG 1061, ISO 21501-4 |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + Touchscreen UI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Model | PLD-0201L |
| Measurement Principle | Light Obscuration (LO) / Optical Blockage |
| Detection Range | 1 µm to 450 µm |
| Sensitivity | 1 µm (per ISO 4402) or 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channel Configuration | 8 user-definable size channels |
| Counting Accuracy | ≤5% coincidence error at 10,000 particles/mL |
| Sample Volume Accuracy | ±1% |
| Flow Control | Precision piston pump with electromagnetic flow regulation (5–60 mL/min) |
| Pressure Range | −0.6 to +0.7 MPa (integrated positive/negative pressure pretreatment) |
| Viscosity Limit | ≤350 cSt (mm²/s) |
| Operating Temperature | Ambient to 65 °C |
| Environmental Temp. | 0–50 °C |
| Power Supply | 220 V AC, 50 Hz, <80 W |
| Compliance Standards | ISO 4406:1999, NAS 1638, GB/T 14039–2002, GB/T 18854–2002 (ISO 11171:1999), JJG 066–95, GJB 380, GJB 420 |
| Data Interface | RS232 serial port |
| Built-in Printer | Yes |
| Calibration Traceability | Certified by AVIC Particle Metrology Test Station (No. 116, National Defense Science & Technology Industry First-Class Particle Metrology Station) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PST-890 |
| Price | USD 53,200 (approx. ¥380,000) |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Calibration Standards | ISO 21501-4, JJG 1061, NIST-Traceable Latex Spheres |
| Software | V8.9 Integrated Particle Analysis Suite (PC & Embedded Touch UI) |
| Sample Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Temperature Range (Fluid) | 0–80 °C |
| Environmental Operating Range | −15–50 °C |
| Counting Channels | 1000 configurable channels (user-definable from 4 to 128 size bins) |
| Detection Range | 1–450 µm (extended range 0.03–3000 µm optional) |
| Custom Ranges | 1–100 µm, 4–70 µm(c), 0.1 µm(c) |
| Sampling Accuracy | <±1% |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Resolution | >95% (per ChP 2015/2020), <10% (per USP <788>, ISO 21501-4) |
| Compliance | GB/T 11446.9–2013, ChP 0903, USP <788>/<789>/<797>, EP 10.0/9.0/8.0, BP 2019/2018, JP 17/16/15, IP 2015, WHO IntPh IV, YBB 00272004–2015, GB 8368, ISO 21510, ISO 11171, NAS 1638, ISO 4406, SAE AS4059, MIL-STD-1246C, JIS B 9933, IP 564/565, ROC T 17216, GB/T 14039, DL/T 432, DL/T 1096, JB/T 9737, GJB/T 420A/B, GB/T 18854 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Model | PLD-0201I |
| Measurement Principle | Light Obscuration (LO) per ISO 11171:1999 / ISO 4406:1999 / NAS1638 / GJB420B |
| Laser Sensor | 7th-Generation Narrow-Beam Laser Detector (PCF-7A) |
| Measurement Range | 1–450 µm |
| Sensitivity | 1 µm (per ISO 4402), 4 µm(c) (per ISO 11171 & GB/T 18854) |
| Channels | 8 user-configurable size thresholds |
| Sample Volume Accuracy | ±1% |
| Flow Rate Control | 5–60 mL/min via precision piston pump with electromagnetic flow regulation |
| Pressure Range | –0.06 to 0.7 MPa (dual positive/negative pressure pre-treatment system) |
| Viscosity Handling | up to 350 cSt |
| Max Particle Concentration | 10,000 particles/mL (≤5% coincidence error) |
| Test Duration | Adjustable, default 12.5 s |
| Operating Temp | Ambient to 65 °C |
| Ambient Temp | 0–50 °C |
| Power | 220 V AC, 50 Hz, <80 W |
| Calibration Compliance | GB/T 18854–2002, ISO 11171:1999, JJG 066–95 |
| Data Output | Real-time particle count/size distribution, histogram, ISO 4406 & NAS1638 contamination grade assignment, built-in thermal printer |
| Interface | RS232 serial port |
| Software | P6.4 Analysis Suite (integrated LabPC7 platform) |
| Regulatory Support | GLP-compliant audit trail, FDA 21 CFR Part 11-ready configuration (optional), traceable calibration certificate available from National Defense Science & Technology Industry First-Class Particle Metrology Station (No. 116) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2GT |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.5–20.0 µm (standard), customizable to 1–100 µm or 4–70 µm(c) |
| Resolution | 0.1 µm(c) minimum detectable threshold |
| Sampling Accuracy | <±1% |
| Measurement Accuracy | <±3% (typical) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Output | 4–20 mA analog signal with configurable alarm triggers |
| Calibration Standards | JJG 1061, ISO 21501-2, NIST-traceable latex sphere reference materials |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen GUI) |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP environments |
| Brand | PULUODY |
|---|---|
| Model | PST-890 |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Sensor |
| Particle Size Range | 1–450 µm (optional extended to 0.03–3000 µm) |
| Resolution | >95% (ChP 2015/2020 calibrated), <10% (USP/ISO 21501 calibrated) |
| Channel Count | 1000 adjustable channels (customizable from 4 to 128 size bins) |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Operating Temperature | Fluid 0–80 °C, Ambient –15–50 °C |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2-T |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Scattering |
| Detection Range | 0.1–1.0 µm & 0.1–0.5 µm (standard) |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Piston Pump + Electromagnetic Flow Regulation |
| Sampling Accuracy | < ±1% |
| Counting Accuracy | < ±3% (typical) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with configurable alarm threshold |
| Data Reporting | Particles per mL and ISO 4406 / NAS 1638 contamination grade |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Software (PC & Touchscreen Edition) |
| Compliance Support | FDA 21 CFR Part 11 audit trail ready (with optional configuration), GLP/GMP traceable operation |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | OPC-2300M |
| Price | USD 13,800 (FOB) |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Sensor Generation | 8th-Generation |
| Measuring Range | 2–750 µm (configurable up to 1000 µm) |
| Size Channels | 1000-user-definable channels, standard presets: 1–100 µm, 2–125 µm, 2–250 µm, 5–500 µm |
| Resolution | 0.1 µm |
| Resolution Accuracy | ±10% (per ISO 21501-4) |
| Counting Accuracy | <±3% typical (NIST-traceable calibration) |
| Coincidence Error | ≤5% at 9,999 particles/mL |
| Maximum Detectable Concentration | 9,999,999 particles/mL |
| Sampling Interval | 5 s – 9 h (programmable) |
| Flow Rate | 6–500 mL/min |
| Operating Pressure | 0–0.6 MPa (standard), 0–31.5 MPa (with optional pressure regulator) |
| Fluid Temperature Range | −10 °C to +80 °C |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, AC fine test dust, MTD |
| Output Interfaces | 4–20 mA analog, RS232, RS485 |
| Data Storage | Internal non-volatile memory + external USB/SD logging |
| Display | Backlit LCD with membrane keypad |
| Enclosure Rating | IP65 (optional IP67) |
| Power Supply | 9–30 VDC or 220 VAC |
| Alarm Functions | Particle count threshold, sensor fault, flow interruption, temperature/pressure out-of-range |
| Brand | PLULODY/PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | PLD Series |
| Pricing | Upon Request |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | PS8011+ |
| Price Range | USD 135 – 525 |
| Material Options | PP, PE, PFA, PEEK, PFAD, High-Silica Borosilicate Glass |
| Volume Options | 50 mL to 1000 mL |
| Particle Cleanliness Level | RCL < 15 particles per 100 mL |
| Certified Cleanliness Classes | ISO Class 1–9 (per ISO 14644-1) |
| Particle Detection Thresholds | 0.1 µm, 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 5.0 µm |
| Average Outgoing Quality Limit (AOQL) | 0.5% |
| Compliance Standards | ISO 3722, ISO 14644-1, GB/T 17484, GB 50073-2001, JIS B9925:1997, JIS K0554:1995 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-268A |
| Ceramic Crucible | Low-form, 30 mL |
| Inner Iron Crucible | Galvanized steel, 75 ± 5 mL with lid |
| Outer Iron Crucible | Galvanized steel, 190 ± 10 mL with lid |
| Tripod Stand | Stainless steel, height 250 ± 10 mm, ring diameter Φ130 ± 5 mm |
| Flame Shield | Stainless steel, conical bore—top opening Φ90 ± 2 mm, bottom opening Φ82 ± 2 mm |
| Stainless Steel Cover | Lower cylindrical section height 50–53 mm |
| Gas Burner | Metric-pattern gas blowtorch (Conradson-type) |
| Brand | PULUODY |
|---|---|
| Model | PMT-2LD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Dual-Laser Narrow-Beam Light Obscuration |
| Detection Range | 0.5–20.0 µm (standard) |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detector |
| Sampling Method | Precision Metering Piston Pump |
| Flow Control | Dual-Stage Electromagnetic + Precision Piston Pump |
| Accuracy | ±3% typical |
| Volume Accuracy | ±1% |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Output | 4–20 mA analog interface with configurable particle concentration alarm |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-traceable latex sphere reference |
| Software | V8.3 Integrated Analysis & Calibration Software (PC + touchscreen UI) |
| Display | Color LCD touchscreen + optional wireless keyboard/mouse |
| Power Input | 100–265 VAC, 50–60 Hz |
| Compliance | Designed for GLP/GMP-aligned environments |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PS3200-6L |
| Capacity | 6 L |
| Ultrasonic Frequency | 53 kHz |
| Ultrasonic Power | ≥200 W |
| Power Adjustment | Yes (40–100%, 1% stepwise) |
| Temperature Control Range | 20–60 °C |
| Heating Power | 150 W |
| Timer Range | 1–199 min |
| Tank Dimensions | 30 × 15 × 15 cm |
| Overall Dimensions | 33 × 18 × 29 cm |
| Power Supply | 220 V / 50 Hz |
| Noise Reduction Lid | Included |
| Manual Drain Valve | Yes |
| Construction | 304 Stainless Steel Tank & Argon-Welded Mesh Basket |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | CLDEE-CCACS2.0 |
| Price | USD 5,150 (approx.) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601XY |
| Instrument Type | Optical Particle Counter (Light Obscuration Principle) |
| Detection Range | 1–450 µm (optional extended range: 0.03–3000 µm) |
| Channel Count | 1000 customizable size channels (down to 0.01 µm resolution) |
| Flow Control | Dual-precision metering piston pump + ultra-precise electromagnetic flow control system |
| Compliance | USP <788>, <789>, <797> |
| Brand | PULUODY |
|---|---|
| Model | PMT-2801 |
| Detection Principle | Dual-laser light scattering (narrow-beam, 8th-generation) |
| Particle Size Range | 0.1–0.5 µm (standard) |
| Accuracy | ±3% typical |
| Sampling Precision | <±1% |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Flow Control | Precision piston pump + electromagnetic flow regulation |
| Compliance | USP <788>, EP 2.9.19, BP, ChP 2015/2020, GB 8368, ISO 21501-4, JJG 1061 |
| Data Output | 4–20 mA analog interface |
| Power Input | 100–265 VAC, 50–60 Hz |
| Software | PULUODY V8.3 Integrated Analysis & Calibration Suite (PC + touchscreen GUI) |
| Operating Interface | Color LCD touch screen + optional wireless keyboard/mouse |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-H |
| Price | USD 72,800 (approx.) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.5–5.0 µm |
| Repeatability | ≤3% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Metering Plunger Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Sample Interface | 4–20 mA Analog Output |
| Data Acquisition | iPad-Compatible Wireless Interface |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Reporting Units | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Voltage Input | 100–265 VAC, 50–60 Hz |
| Counting Accuracy | <±1% volumetric error |
| coincidence limit | 1000 particles/mL (≤2.5% coincidence error) |
| Brand | PULUODY |
|---|---|
| Model | OPC |
| Origin | Shaanxi, China |
| Detection Principle | Light Obscuration (LO) with Dual-Laser Narrow-Beam Technology |
| Measurement Range | 1–150 µm |
| Calibration Standards Supported | ISO 4406, NAS 1638, SAE AS4059, ISO 11171, MIL-STD-1246C, GB/T 14039, DL/T 432, GJB/T 420A/B, GB/T 18854 |
| Operating Pressure | 0–0.6 MPa (standard), up to 31.5 MPa (with integrated pressure regulator) |
| Sample Flow Rate | 6–500 mL/min |
| Fluid Temperature Range | −10 °C to +80 °C |
| Viscosity Limit | ≤500 cSt (online mode) |
| Output Interfaces | 4–20 mA analog, RS232 serial, optional alarm relay |
| Power Supply | 9–30 VDC |
| Compliance | Designed for industrial process monitoring per ISO 21501-4, ASTM D6786, and IEC 61508 SIL2-ready architecture |
| Enclosure Rating | IP65 (standard), optional IP67 |
| Software | Integrated firmware with configurable reporting (particles/mL + contamination code) |