Empowering Scientific Discovery

GreenPrima Aqualysis 800A Total Alkalinity Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand GreenPrima
Origin United Kingdom
Manufacturer Type Manufacturer
Origin Category Imported
Model Aqualysis 800A
Measurement Principle Titrimetric Colorimetry
Measurement Time 2–8 min (alkalinity-dependent)
Accuracy ±2% of selected reagent upper limit
Repeatability ±2% of selected reagent upper limit
Power Supply 85–265 VAC, 47–63 Hz
Power Consumption 25 VA (operational), 3.5 VA (standby)
Enclosure Rating IP65
Dimensions 400 × 300 × 180 mm (H×W×D)
Weight 4 kg
Display Color LCD
Output Options 4 programmable relay outputs (250 V, 4 A max), 1 isolated 4–20 mA output (750 Ω max), 1 RS485 interface
Input Options 2 programmable digital inputs (IN1: start analysis
IN2 stop analysis)
Sampling Interval 1–360 min (configurable) or triggered externally/flow-synchronized
Rinse Duration 15–1800 s (user-configurable)
Sample Water Requirements pH 4–10
Environmental Operating Range 10–40 °C
Units Supported °dH, °f, ppm CaCO₃, mmol/L

Overview

The GreenPrima Aqualysis 800A Total Alkalinity Analyzer is an industrial-grade, fully automated online analyzer engineered for continuous or interval-based quantification of total alkalinity in aqueous process streams. It operates on the principle of titrimetric colorimetry—where a standardized acid titrant is precisely dosed into the sample until a pH-sensitive indicator undergoes a stoichiometric color transition, detected by a high-stability photometric sensor. This method conforms to established titration-based alkalinity standards including ISO 9963-1, ASTM D1067, and APHA Standard Method 2320 B. Designed for deployment in demanding utility and pharmaceutical water systems, the Aqualysis 800A delivers traceable, reproducible measurements without operator intervention—enabling real-time feedback for lime softening, ion exchange regeneration, and boiler feedwater conditioning control loops.

Key Features

  • Robust titrimetric colorimetric measurement architecture with dual-wavelength photometric detection for enhanced interference rejection
  • Automatic calibration and system diagnostics—including reagent depletion alerts, pump stroke validation, and optical path integrity checks
  • Compact footprint (400 × 300 × 180 mm) and lightweight design (4 kg) optimized for panel mounting or skid integration
  • Low operational cost profile: minimal reagent consumption (6 months between maintenance cycles)
  • Flexible operation modes: continuous monitoring or programmable interval analysis (1–360 minutes), plus external trigger capability via digital input or flow-pulse synchronization
  • Configurable rinse protocol (15–1800 seconds) to prevent cross-contamination and maintain long-term baseline stability
  • Four programmable relay outputs supporting alarm staging, pump control, or softener backwash initiation; one isolated 4–20 mA analog output for PLC/HMI integration
  • Comprehensive local data logging—including measurement history, fault timestamps, calibration records, and diagnostic event logs—with non-volatile memory retention

Sample Compatibility & Compliance

The Aqualysis 800A is validated for use with low-turbidity, non-oily water matrices meeting specified chemical and physical constraints: pH 4–10, dissolved iron < 3 ppm, copper < 0.2 ppm, aluminum < 0.1 ppm, and manganese < 0.2 ppm. It supports operation across a pressure range of 0.2–5 bar (recommended 1–2 bar) and accommodates sample temperatures from 5–40 °C. The analyzer meets IP65 ingress protection for dust- and water-resistant enclosure performance, enabling installation in mechanical rooms, utility corridors, and outdoor instrument shelters. Its firmware architecture supports audit-trail generation and user-access-level configuration—facilitating alignment with GMP Annex 11, FDA 21 CFR Part 11 (when paired with compliant SCADA), and ISO/IEC 17025 quality management requirements.

Software & Data Management

The embedded controller features a menu-driven color LCD interface with multilingual support (English, German, French, Spanish). All configuration parameters—including measurement units (°dH, °f, ppm CaCO₃, mmol/L), sampling frequency, rinse duration, alarm thresholds, and relay logic—are accessible locally or remotely via Modbus RTU over RS485. Data export is supported through ASCII-formatted serial dumps or periodic register polling. Internal storage retains ≥30 days of high-resolution measurement data (1-minute intervals) and full diagnostic logs. Optional integration with GreenPrima’s MCS-series multi-channel selector enables centralized monitoring of up to eight independent sample points—ideal for cooling tower arrays or multi-boiler plant configurations.

Applications

  • Real-time alkalinity control in industrial boiler feedwater systems to prevent caustic embrittlement and scale formation
  • Monitoring softener effluent quality during sodium cycle regeneration and hardness breakthrough detection
  • Process assurance in pharmaceutical purified water (PW) and water-for-injection (WFI) distribution loops per USP and EU GMP Annex 1
  • Performance verification of lime-soda ash softening units in municipal and industrial pretreatment plants
  • Trend analysis and early warning of carbonate system imbalance in recirculating cooling water systems (per CTI Guidelines and ASHRAE 12–2022)
  • Regulatory compliance reporting for EPA NPDES discharge permits requiring alkalinity monitoring

FAQ

What measurement principle does the Aqualysis 800A employ?
It uses titrimetric colorimetry based on acid–base neutralization with a bromocresol green–methyl red indicator system, detecting the endpoint photometrically.
Can the analyzer operate unattended for extended periods?
Yes—designed for >6 months of uninterrupted operation with scheduled reagent replacement and annual verification per ISO/IEC 17025 guidelines.
Is remote configuration and data retrieval supported?
Yes, via Modbus RTU over RS485; no proprietary software required for basic parameter access or log extraction.
How does the unit handle sample interferences such as turbidity or metal ions?
Pre-filtration (5 µm recommended) and adherence to specified metal concentration limits ensure photometric accuracy; built-in blank correction compensates for minor background absorbance.
What certifications apply to the Aqualysis 800A for regulated environments?
CE-marked per EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU; documentation package includes Declaration of Conformity, Factory Calibration Certificate, and IQ/OQ-ready test protocols.