Empowering Scientific Discovery

Restek ProFLOW 6000 Handheld Digital Electronic Flow Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Restek
Model ProFLOW 6000
Origin USA
Flow Range 0.5–500 mL/min
Accuracy ±2% of reading or ±0.05 mL/min (whichever is greater)
Calibration Traceability NIST-traceable
Explosion Protection Certified for flammable and explosive gases (Ex-rated)
Operating Temperature 0–48 °C
Relative Humidity 0–97% RH (non-condensing)
Power Supply 2 × AA batteries
Data Interface USB
Certifications CE, RoHS, WEEE
Enclosure Options Handheld and benchtop configurations
Auto-shutdown Yes
Warranty 1 year

Overview

The Restek ProFLOW 6000 Handheld Digital Electronic Flow Meter is a precision-engineered volumetric flow measurement instrument designed specifically for gas chromatography (GC) laboratories and analytical instrumentation environments where accurate, real-time, bidirectional gas flow quantification is critical. Unlike thermal mass flow meters that infer flow from heat transfer properties—making them sensitive to gas composition changes—the ProFLOW 6000 employs a calibrated laminar flow element combined with differential pressure sensing and temperature-compensated electronics to deliver true volumetric flow readings across a broad spectrum of clean, dry, non-corrosive gases. Its design adheres to fundamental principles of Poiseuille flow physics, ensuring high reproducibility and minimal dependence on gas-specific calibration factors. This makes it especially suitable for GC carrier gas verification (e.g., H2, He, N2, Ar), detector gas supply validation, and purge/vent line monitoring—applications where traceable accuracy, intrinsic safety, and operational flexibility are mandatory.

Key Features

  • Volumetric flow measurement range of 0.5–500 mL/min with an accuracy of ±2% of reading or ±0.05 mL/min (whichever is greater), validated against primary NIST-traceable standards.
  • Intrinsically safe design certified for use with flammable and explosive gases—including hydrogen—meeting international Ex classification requirements for hazardous area operation.
  • Dual form factor: fully functional handheld unit optimized for field verification and benchtop version for fixed-station integration in QC labs or instrument qualification workflows.
  • Ergonomic side-grip housing with textured, slip-resistant surface—engineered for prolonged operator comfort and mechanical durability during routine daily use.
  • Real-time bidirectional flow detection capability, enabling validation of both forward and reverse gas movement in purge valves, backflush systems, or leak-check setups.
  • Integrated audible and visual over-range alarm, automatic power-down after 10 minutes of inactivity, and low-battery indicator to ensure measurement integrity and battery longevity.
  • USB interface compliant with CDC/ACM class protocols for direct data streaming to Windows-based laboratory software; no proprietary drivers required.
  • CE-marked and compliant with EU directives including RoHS (2011/65/EU) and WEEE (2012/19/EU); fully documented for GLP/GMP-aligned instrument qualification (IQ/OQ/PQ).

Sample Compatibility & Compliance

The ProFLOW 6000 is validated for use with clean, dry, non-corrosive gases—including but not limited to helium, nitrogen, hydrogen, argon, air, carbon dioxide, methane, and synthetic air mixtures. It is explicitly not intended for use with corrosive (e.g., Cl2, NH3, H2S), condensable (e.g., saturated hydrocarbons, solvent vapors), or particulate-laden streams. Gas compatibility aligns with ASTM D3176-20 (Standard Practice for Ultimate Analysis of Coal and Coke) and ISO 8573-1:2010 Class 4 purity requirements for compressed air and inert gases used in analytical instrumentation. For regulated environments—including pharmaceutical QC labs operating under FDA 21 CFR Part 11—the device supports audit-ready data export and is compatible with electronic lab notebook (ELN) integration via timestamped CSV output. Annual recalibration is recommended per Restek’s technical bulletin TB-PROF6000-01 to maintain metrological confidence and compliance with ISO/IEC 17025:2017 clause 6.4.10 (Measurement Traceability).

Software & Data Management

No proprietary software installation is required. The ProFLOW 6000 enumerates as a standard USB CDC serial device, allowing seamless integration with common data acquisition platforms such as LabVIEW, MATLAB, Python (via PySerial), or custom LIMS interfaces. Each measurement record includes UTC timestamp, flow value (mL/min), direction flag (+/−), unit ID, and battery status. Data logs are exported in UTF-8 encoded CSV format with header rows compliant with ASTM E1382-95 (Standard Guide for Computerized Instrument Systems in Analytical Chemistry). Firmware updates are delivered via signed .hex files through Restek’s secure customer portal, supporting cryptographic verification and rollback capability—critical for regulated environments requiring change control documentation.

Applications

  • Verification of carrier gas flow rates in GC and GC-MS systems prior to method execution or system suitability testing.
  • Leak testing and pressure decay validation of GC inlet liners, septa, and column connections using controlled purge flows.
  • Calibration cross-checking of built-in electronic pneumatic controllers (EPCs) in modern GC instruments (e.g., Agilent 8890/8860, Thermo ISQ, Shimadzu GC-2030).
  • Monitoring split/splitless injection flow profiles during method development and troubleshooting retention time variability.
  • Field validation of gas generators (e.g., hydrogen, nitrogen) supplying multiple instruments within central lab infrastructure.
  • Supporting ISO 17025-accredited proficiency testing programs requiring third-party traceable flow verification reports.

FAQ

Is the ProFLOW 6000 suitable for measuring hydrogen flow in GC applications?

Yes—it is Ex-certified for use with hydrogen and other flammable gases, making it appropriate for high-sensitivity hydrogen carrier gas systems.
What does NIST-traceable calibration mean for my lab’s compliance?

It ensures measurement uncertainty can be linked unbrokenly to national standards, satisfying ISO/IEC 17025, CLIA, and FDA audit requirements for documented metrological traceability.
Can I use the same ProFLOW 6000 for both helium and nitrogen without recalibration?

Yes—its volumetric principle eliminates gas-specific correction factors required by thermal mass flow meters, provided gases meet cleanliness and dryness specifications.
How often should I schedule recalibration?

Restek recommends annual recalibration; more frequent intervals may be necessary in high-use or regulated environments per internal SOP or quality agreement.
Does the USB interface support real-time streaming during GC method runs?

Yes—continuous polling at up to 10 Hz is supported via standard serial commands, enabling synchronized logging with chromatographic data acquisition.