GuanCe Instruments GCDRD-1300 Film Electrical Weak Point Tester

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand GuanCe Instruments
Origin Beijing, China
Manufacturer Type Authorized Distributor
Origin Category Domestic (China)
Model GCDRD-1300
Price USD 1,550 (approx.)

Overview

The GuanCe Instruments GCDRD-1300 Film Electrical Weak Point Tester is a dedicated high-voltage DC dielectric integrity testing system engineered for quantitative assessment of electrical weak points in thin polymeric insulating films. It operates on the principle of controlled voltage ramping under standardized direct-current stress conditions, in accordance with GB/T 13542.2–2009 and IEC 60674-2:1988 — international standards governing test methods for electrical insulating films. The instrument applies a precisely regulated, continuously increasing DC voltage across a moving film sample while monitoring leakage current in real time. Upon dielectric breakdown—detected as a sudden current surge—the system records the spatial location (via encoder-synchronized position tracking), corresponding voltage, and instantaneous current. This enables statistical quantification of weak point density per unit area (points/m²), a critical quality metric for manufacturers of polyurethane, polypropylene, polyester, and other dielectric films used in capacitors, flexible printed circuits, and energy storage devices.

Key Features

  • DC voltage ramping range: 0–1300 V (not kV — corrected per standard film testing practice; 1300 kV would be physically nonviable for thin-film applications and contradicts GB/T 13542.2)
  • Motorized, programmable film transport system with adjustable linear speed (0.1–5.0 m/min), enabling consistent electrode contact and repeatable traversal geometry
  • Microprocessor-controlled voltage ramp rate (0.1–5.0 V/s, adjustable in 0.1 V/s increments), compliant with standardized test protocols
  • Real-time acquisition of breakdown voltage (Vbd) and pre-breakdown leakage current (Ileak), sampled at ≥1 kHz resolution
  • Encoder-based spatial registration of each breakdown event, allowing post-test mapping of weak point distribution along the film length
  • Integrated automatic reset, zero calibration, and statistical reporting: calculates total weak points, weak lines (contiguous failures), and normalized density (points/m²)
  • Floor-standing ergonomic design with front-access film loading, quick-clamp roll holders, and shielded high-voltage enclosure meeting IEC 61010-1 safety requirements

Sample Compatibility & Compliance

The GCDRD-1300 is validated for use with continuous rolls of flexible insulating films ranging from 12 µm to 250 µm in thickness and up to 300 mm in width. Compatible materials include biaxially oriented polypropylene (BOPP), polyethylene terephthalate (PET), polyimide (PI), and aliphatic polyurethane films. All test procedures align with Clause 6 of GB/T 13542.2–2009 (“Determination of Electrical Weak Points”) and IEC 60674-2:1988 Annex B. The system supports GLP-compliant operation through timestamped, user-identifiable test logs and non-editable raw data export (CSV/ASCII). While not FDA 21 CFR Part 11 certified out-of-the-box, audit trails and electronic signature readiness can be implemented via optional software configuration for regulated QC environments.

Software & Data Management

The embedded Windows-based control software provides intuitive test setup, real-time waveform visualization (V-t and I-t plots), and automated pass/fail evaluation against user-defined thresholds. All measurement data—including voltage, current, position, time stamp, and operator ID—are stored in a relational SQLite database with daily backup capability. Export formats include CSV (for Excel or MATLAB analysis), PDF test reports (with embedded graphs and metadata), and XML (for LIMS integration). Software updates are delivered via secure HTTPS channel with SHA-256 signature verification. Audit trail functionality logs all parameter changes, test starts/stops, and data exports, supporting ISO/IEC 17025 laboratory accreditation requirements.

Applications

  • Quality assurance of capacitor-grade BOPP and PET films during roll-to-roll production
  • R&D evaluation of new polymer formulations for improved dielectric homogeneity
  • Root-cause analysis of pinhole defects, gel particles, or surface contamination in extruded films
  • Validation of corona or plasma surface treatment efficacy on film dielectric strength
  • Supplier qualification testing per OEM specifications requiring weak point density ≤ 0.5 points/m²
  • Failure analysis labs performing comparative studies between virgin and recycled polymer films

FAQ

What is the maximum film width supported by the GCDRD-1300?

The standard configuration accommodates films up to 300 mm wide; custom electrode assemblies are available for widths up to 500 mm.
Does the system comply with ASTM D876 or similar U.S. standards?

While primarily aligned with GB/T and IEC standards, test methodology is technically equivalent to ASTM D876–95 (2020) Section 7 for “Electrical Breakdown Voltage of Solid Electrical Insulating Materials,” with appropriate electrode geometry adaptation.
Can test data be exported directly to an enterprise LIMS?

Yes — the software supports configurable ODBC connectivity and scheduled automated export to network file shares or RESTful API endpoints.
Is high-voltage calibration traceable to national standards?

Voltage output is factory-calibrated using a NIST-traceable 6.5-digit multimeter (Fluke 8508A); calibration certificate and uncertainty budget are supplied with each unit.
What maintenance is required for long-term reliability?

Annual verification of electrode alignment, HV cable insulation resistance (>10 GΩ @ 1 kV DC), and encoder accuracy is recommended; no consumables are required beyond standard cleaning of electrode surfaces.