Empowering Scientific Discovery

Jiayuan MD200-1A Individual Channel-Adjustable Dry-Block Nitrogen Evaporator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Jiayuan
Origin Beijing, China
Model MD200-1A
Heating Method Dry-block heating
Temperature Range Ambient +5°C to 150°C
Temperature Uniformity ±0.5°C (at 40–100°C)
Tube Capacity 0.5 mL to 15 mL
Gas Flow Rate 0–10 L/min
Sample Positions 12
Heating Power 200 W
Display LED, 0.1°C resolution
Timer Range 0–99 h 59 min
Max Operating Pressure ≤0.1 MPa
Dimensions 280 × 240 × 500 mm
Safety Over-temperature protection, real-time fault detection & audible alarm
Modular Compatibility BK19 (96 × 0.2 mL tubes), BK20 (8-well microplate)

Overview

The Jiayuan MD200-1A is a precision-engineered, dry-block nitrogen evaporator designed for high-throughput, reproducible solvent removal in analytical and preparative laboratories. Unlike water-bath systems, it employs thermally stable aluminum heating blocks with rapid thermal response and minimal cross-contamination risk. Its core operation relies on controlled, low-velocity nitrogen gas directed perpendicularly onto sample surfaces—reducing solvent vapor pressure and accelerating evaporation under inert conditions. This method preserves thermolabile analytes (e.g., steroids, pesticides, pharmaceutical metabolites) while eliminating oxidative degradation commonly observed during rotary evaporation or open-air drying. The instrument is widely deployed in QC/QA labs supporting HPLC, GC-MS, LC-MS/MS, and ELISA workflows where parallel processing of up to 12 samples—each under independently optimized gas flow and temperature—is critical for throughput and data integrity.

Key Features

  • Individual channel gas flow control: Each of the 12 gas nozzles features independent on/off and fine-flow adjustment, enabling selective concentration without nitrogen waste—essential for cost-sensitive or regulated environments.
  • Adjustable gas manifold height: The vertical position of the gas distribution chamber can be manually calibrated to match solvent meniscus level, minimizing gas turbulence and maximizing evaporation efficiency across varying tube volumes (0.5–15 mL).
  • Dry-block thermal architecture: A 200 W resistive heating system delivers uniform temperature distribution (±0.5°C at 40–100°C) with <30 min ramp time from 40°C to 150°C; no water maintenance or corrosion concerns.
  • Real-time operational monitoring: LED display shows setpoint and actual temperature (0.1°C resolution), remaining timer (up to 99 h 59 min), and system status indicators—including active fault alerts for over-temperature or gas interruption.
  • Integrated safety mechanisms: Dual-stage thermal protection includes programmable upper-limit cutoff and hardware-based over-temperature fuse, compliant with IEC 61010-1 requirements for laboratory electrical equipment.
  • Modular interchangeability: Compatible with BK19 (96-position 0.2 mL PCR tube block) and BK20 (8-well microplate adapter) modules—both engineered for precise thermal coupling and easy tool-free installation.

Sample Compatibility & Compliance

The MD200-1A accommodates standard conical-bottom and round-bottom tubes (0.5–15 mL), as well as microcentrifuge formats via optional BK19 and BK20 modules. Its dry-block design eliminates immersion-related contamination risks and supports use in Class II biosafety cabinets or fume hoods when handling volatile, toxic, or odoriferous solvents (e.g., chloroform, hexane, acetonitrile). The instrument meets general safety standards per IEC 61010-1 and is suitable for GLP-compliant environments when operated with documented SOPs, calibration records, and audit-trail-enabled external logging. While not inherently 21 CFR Part 11–compliant, its deterministic timer, fixed setpoints, and non-networked architecture simplify validation for regulated applications requiring traceable, repeatable endpoint control.

Software & Data Management

The MD200-1A operates via embedded firmware without external software dependency—ensuring reliability, reduced IT overhead, and immunity to OS updates or driver conflicts. All parameters (temperature setpoint, timer duration, gas activation state per channel) are retained after power cycling. For laboratories requiring electronic recordkeeping, analog voltage outputs (0–5 V) for temperature and timer signals are available via optional interface module (sold separately), enabling integration with SCADA systems or validated data acquisition platforms. Calibration certificates traceable to NIST standards can be provided upon request, supporting ISO/IEC 17025-aligned metrological assurance programs.

Applications

  • High-throughput sample prep for environmental analysis (PAHs, PCBs, organochlorine pesticides in soil/water extracts)
  • Pharmaceutical impurity profiling: post-extraction concentration of API degradation products prior to UPLC-MS quantification
  • Clinical toxicology: parallel evaporation of urine or plasma extracts before derivatization and GC-FID analysis
  • Food safety testing: cleanup of QuEChERS extracts prior to multi-residue pesticide screening by LC-MS/MS
  • Forensic toxicology: gentle concentration of blood homogenates containing unstable benzodiazepines or cannabinoids
  • Academic research: reproducible solvent exchange in nanoparticle synthesis or peptide purification workflows

FAQ

Can the MD200-1A be used with solvents boiling below 40°C, such as dichloromethane or pentane?

Yes—provided ambient lab temperature remains stable and nitrogen flow is precisely tuned to avoid splashing or foaming. Use lower temperature setpoints (e.g., 35–45°C) and monitor evaporation visually during method development.
Is the BK19 module compatible with standard 96-well PCR plates?

No—the BK19 is dimensionally optimized for 0.2 mL individual PCR tubes in rack format; for full 96-well plate compatibility, the BK20 adapter (8-position, accommodating standard microplates stacked vertically) is required.
Does the instrument support external gas pressure regulation?

It accepts inlet nitrogen at ≤0.1 MPa (1 bar); an external needle valve or mass flow controller is recommended for precise sub-L/min control, especially for low-volume samples.
What maintenance is required for long-term accuracy?

Annual verification of temperature uniformity using a calibrated PT100 probe across all 12 positions is advised. Clean gas nozzles monthly with lint-free swabs and isopropanol to prevent polymer residue buildup.
Can the MD200-1A be validated for GMP environments?

Yes—its deterministic controls, absence of firmware updates, and mechanical simplicity support IQ/OQ/PQ protocols. Documentation packages including URS, DQ, and calibration templates are available upon request.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0