Zhengye XG5010A Benchtop X-ray Inspection System
| Brand | Zhengye |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | XG5010A |
| X-ray Source | Sealed Tube, 90 kV |
| Minimum Focal Spot Size | 5 µm / 7 µm |
| Detector Type | Flat Panel Detector (Standard) |
| Load Capacity | 10 kg |
| Stage Options | Tilt-only (±45°), Rotation-only (360°), or Combined Tilt + Rotation |
| Stage Dimensions | 500 mm × 500 mm (standard) |
| Effective Field of View | 460 mm × 460 mm |
| System Dimensions (L×W×H) | 1270 mm × 1340 mm × 1800 mm |
| Weight | ~1500 kg |
| Power Supply | 220 V / 50 Hz |
| Max. Power Consumption | 2.5 kW |
| Radiation Leakage | ≤1.0 µSv/h (measured per third-party certified dosimeter) |
| Image Processing | Real-time enhancement, multi-format export (DICOM, TIFF, PNG, JPEG), on-the-fly annotation & measurement |
| Measurement Capabilities | Linear distance, circle diameter, concentricity, point-to-center distance, CNC path memory & auto-replay |
| Navigation | Large overview map with click-to-move stage positioning |
| Software Features | Super-resolution reconstruction algorithm, GLP-compliant audit trail (optional), FDA 21 CFR Part 11–ready configuration (with optional electronic signature module) |
Overview
The Zhengye XG5010A Benchtop X-ray Inspection System is a high-resolution, microfocus X-ray imaging platform engineered for non-destructive internal inspection of industrial components across electronics, automotive, energy storage, and advanced manufacturing sectors. Operating on the principle of differential X-ray attenuation, the system generates high-contrast transmission radiographs by directing a collimated beam from a sealed-tube microfocus source (90 kV, focal spot sizes down to 5 µm) through the sample onto a high-sensitivity flat-panel detector. Its mechanical architecture supports precise geometric magnification—enabling sub-micron feature resolution in projection geometry—and maintains consistent image fidelity across variable sample thicknesses and material densities. Designed for integration into production QA/QC workflows and R&D laboratories, the XG5010A complies with international radiation safety standards (IEC 61331-1, GBZ 138–2002), with verified leakage dose rates ≤1.0 µSv/h at 5 cm from any external surface.
Key Features
- Microfocus X-ray Source: Sealed tungsten-target tube rated at 90 kV; selectable focal spot sizes (5 µm standard, 7 µm high-power mode) ensure optimal trade-off between spatial resolution and photon flux for diverse sample types.
- Multimodal Motion Control: Three configurable stage options: tilt-only (±45°), rotation-only (360° continuous), or combined tilt+rotation—enabling true 3D tomographic acquisition and comprehensive defect localization without manual repositioning.
- CNC-Based Metrology Engine: Integrated coordinate measurement functionality supports ISO 10360–compliant dimensional analysis—including linear distances, circle diameters, concentricity, radial runout, and point-to-center offsets—with programmable motion paths for repeatable small-batch inspection.
- Real-Time Super-Resolution Imaging: Proprietary software algorithm enhances edge sharpness and noise suppression while preserving quantitative grayscale integrity—critical for detecting voids, cracks, solder bridges, delaminations, and foreign object debris (FOD) in BGA packages, battery electrodes, or ceramic substrates.
- Intuitive Navigation Interface: Dual-view GUI displays both a real-time low-resolution overview map and a high-resolution zoomed region; mouse-click navigation enables sub-pixel stage positioning accuracy within ±5 µm repeatability.
- Radiation-Safe Enclosure: Lead-lined steel chassis with interlocked door sensors, warning LEDs, and redundant hardware-based exposure cutoffs—certified to meet Class I radiation device requirements under Chinese NMPA and EU Directive 2013/59/Euratom frameworks.
Sample Compatibility & Compliance
The XG5010A accommodates samples up to 10 kg and 460 mm × 460 mm in footprint, supporting heterogeneous materials including silicon wafers, aluminum die-cast housings, lithium-ion cell stacks, multilayer PCBs, SMT-assembled modules, and sintered ceramics. Its adjustable source-to-detector distance (SDD) and source-to-object distance (SOD) allow optimization of geometric unsharpness and magnification for specific application needs. The system meets ISO/IEC 17025 prerequisites for calibration traceability when used with NIST-traceable reference phantoms. Optional validation packages support IQ/OQ/PQ documentation aligned with GMP Annex 11 and FDA 21 CFR Part 11 requirements—including electronic signature enforcement, user access tiers, and immutable audit logs for all image acquisition, processing, and measurement events.
Software & Data Management
Zhengye’s proprietary X-ray Vision Suite v4.x provides DICOM 3.0–compliant image handling, enabling seamless integration with PACS environments and third-party analysis tools. All acquired projections and reconstructed slices are stored with embedded metadata (kV, µA, exposure time, stage coordinates, operator ID, timestamp). Batch export supports TIFF (16-bit linear), PNG (lossless), JPEG (user-defined quality), and vendor-neutral DICOM-RT formats. Measurement data can be exported to CSV or Excel for statistical process control (SPC) integration. Audit trail records include operator login/logout, parameter changes, image annotations, and report generation—all timestamped and digitally signed where enabled. Software updates follow a controlled release cycle with version-controlled firmware signing and rollback capability.
Applications
- Semiconductor packaging: Wire bond integrity, die attach voiding, mold compound delamination in QFN, BGA, and SiP assemblies.
- Electronics manufacturing: Solder joint inspection (BGA, CSP), component placement verification, tombstoning detection, and popcorning assessment in MLCCs.
- Energy storage: Electrode coating uniformity, separator wrinkling, anode/cathode alignment, and jelly-roll deformation in cylindrical and prismatic Li-ion cells.
- Automotive castings: Porosity mapping, shrinkage cavity identification, and inclusion detection in aluminum engine blocks, transmission housings, and brake calipers.
- Photovoltaics: Interconnect ribbon soldering quality, EVA encapsulant bubble formation, and backsheet microcrack propagation in PERC and TOPCon modules.
- Medical device components: Weld seam integrity in stainless-steel surgical instruments, polymer weld line consistency in disposable fluidic manifolds, and ceramic insulator crack detection in RF ablation probes.
FAQ
What regulatory certifications does the XG5010A hold for international deployment?
The system conforms to IEC 61331-1:2014 (radiation protection), GBZ 138–2002 (Chinese radiation safety), and CE marking under the EU Electromagnetic Compatibility Directive 2014/30/EU. Export versions include RoHS and REACH declarations; FDA 510(k) clearance is not applicable as it is classified as industrial equipment, not a medical device.
Can the XG5010A perform computed tomography (CT)?
Yes—when equipped with the optional 360° rotating stage and CT acquisition module, the system supports cone-beam CT reconstruction with voxel resolutions down to 10 µm (subject to sample size and scan duration). Reconstruction is performed using filtered back-projection or iterative algorithms (SART, OS-SART) within the bundled software suite.
Is remote operation and monitoring supported?
Standard Ethernet (10/100/1000BASE-T) and optional Wi-Fi 6 connectivity enable remote desktop access, live streaming of radiographic views, and centralized fleet management via Zhengye’s CloudLink portal—compatible with TLS 1.2 encryption and LDAP/Active Directory authentication.
How is radiation safety ensured during daily operation?
All operational modes enforce hardware interlocks: door-open detection immediately disables X-ray emission; exposure timers limit maximum pulse duration; and real-time dosimetry alerts trigger automatic shutdown if ambient dose rate exceeds preset thresholds. Annual third-party radiation survey reports are provided with each maintenance contract.
What training and technical support options are available?
Zhengye offers on-site installation commissioning, operator certification courses (8-hour practical curriculum), and annual refresher workshops covering image interpretation, metrology validation, and regulatory documentation. Support includes 24/7 remote diagnostics, spare parts logistics with <72-hour delivery in APAC/EU regions, and firmware update notifications via secure customer portal.