Empowering Scientific Discovery

ShengAohua SH-6G High-Chloride COD Reflux Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ShengAohua
Origin Jiangsu, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model SH-6G
Price Range USD 700–1,400 (FOB)
Digestion Method Reflux Digestion
Heating Module Single Aluminum Alloy Heating Block
Batch Capacity 6 Samples
Rated Heating Power 1500 W
Temperature Accuracy ±1 °C
Sample Vessel Volume 250 mL
Timer Resolution 0.1 s
Cooling Mode Dual-mode (Forced Air + Optional Water Circulation)
Compliance Standard HJ/T 70–2001 (China EPA Standard for COD Determination in High-Chloride Wastewater)

Overview

The ShengAohua SH-6G High-Chloride COD Reflux Digestion System is an engineered laboratory instrument designed for precise and reproducible chemical oxygen demand (COD) determination in wastewater samples containing elevated chloride concentrations—up to 20,000 mg/L Cl⁻. It implements the chlorine correction method specified in China’s Ministry of Ecology and Environment standard HJ/T 70–2001, which mandates reflux digestion under controlled thermal conditions followed by titrimetric or spectrophotometric quantification of residual oxidant. Unlike open-system digesters, the SH-6G integrates a spherical reflux condenser with dual-mode cooling (forced-air convection plus optional water-jacketed condensation), ensuring stable vapor return, minimal reagent loss, and consistent thermal profiles across all six reaction positions. Its single high-emissivity infrared heating block delivers uniform thermal distribution to 250 mL borosilicate digestion vials, minimizing inter-vial temperature variance—a critical factor in achieving inter-laboratory comparability for regulatory reporting.

Key Features

  • Single integrated aluminum alloy heating block with embedded infrared radiant panels and black-crystal glass surface for optimal heat transfer uniformity and thermal stability
  • Six independent digestion stations with individual 250 mL sample vessels, each fitted with standardized spherical reflux condensers
  • Dual cooling architecture: high-CFM AC fan-assisted air cooling supplemented by optional external water-circulating condenser interface for extended runtimes or high-boiling-point matrices
  • High-resolution digital timer with 0.1-second resolution and programmable digestion duration (default 120 minutes; adjustable from 10 to 300 minutes)
  • Automatic end-of-digestion protocol: audible alarm activation, immediate power cutoff to heating elements, and visual status indication on the 5-inch capacitive touchscreen
  • Touchscreen HMI with localized Chinese GUI, one-touch start sequence, real-time temperature monitoring per station, and non-volatile parameter storage
  • Energy-optimized design: 1500 W nominal input power with thermal inertia management, reducing standby losses and improving overall energy efficiency per batch

Sample Compatibility & Compliance

The SH-6G is validated for use with municipal sewage, surface water, industrial effluents (e.g., petrochemical, pharmaceutical, textile), and landfill leachate where chloride interference exceeds typical COD assay thresholds. It supports digestion of samples within the specified measurement range of 30–700 mg/L COD (as O₂), provided chloride concentration remains ≤20,000 mg/L. Performance validation data per HJ/T 70–2001 demonstrates relative standard deviation (RSD) <5% for low-chloride natural waters and <8% for complex organic wastewaters. While not certified to ISO/IEC 17025 or ASTM D1252, its operational parameters align with GLP-aligned laboratory practice requirements for method-defined instrumentation. Users performing regulated environmental testing are advised to conduct in-house system suitability checks—including temperature uniformity mapping, timer calibration, and reflux condensation efficiency verification—prior to routine use.

Software & Data Management

The SH-6G operates via an embedded microcontroller-based firmware platform with no external PC dependency. All user inputs, setpoints, runtime logs, and alarm events are stored locally in non-volatile memory with timestamping (YYYY-MM-DD HH:MM:SS). The touchscreen interface allows export of session records via USB flash drive in CSV format, including start time, target temperature, actual block temperature profile (sampled at 10 s intervals), elapsed digestion time, and completion flag. Audit trail functionality meets basic GLP documentation needs; however, full 21 CFR Part 11 compliance requires integration with third-party LIMS or ELN systems capable of electronic signature enforcement and change control logging.

Applications

  • Regulatory COD analysis of high-chloride industrial discharges under China’s national discharge permit system
  • Wastewater treatment plant process control and effluent compliance monitoring
  • Environmental impact assessment (EIA) sampling campaigns requiring field-deployable, benchtop digestion units
  • Research laboratories evaluating oxidation kinetics of recalcitrant organics in saline matrices
  • Method development and validation studies supporting adaptation of HJ/T 70–2001 to alternative detection chemistries (e.g., dichromate-spectrophotometric, cerimetric titration)

FAQ

Does the SH-6G support automatic chloride correction calculation?
No. The instrument performs only the thermal digestion step. Chloride correction must be applied manually during downstream data reduction per HJ/T 70–2001 equations, using parallel blank and spiked sample titrations.

Can the unit be operated without water cooling?
Yes. The forced-air cooling system is fully functional as a standalone mode. Water cooling is optional and intended for ambient temperatures >35 °C or prolonged multi-batch operation.

What maintenance is required for long-term reliability?
Monthly inspection of condenser seals, quarterly cleaning of fan intake grilles and heating block surfaces with ethanol-dampened lint-free cloth, and annual verification of temperature sensor calibration using a NIST-traceable dry-block calibrator.

Is the 250 mL vessel compatible with standard COD vials from other manufacturers?
Yes—vessels conform to ISO 15705:2002 dimensional specifications for reflux digestion tubes. Users may substitute certified borosilicate glass vials meeting DIN EN ISO 3585 tolerances.

What is the expected service life under routine lab use?
With proper maintenance and adherence to recommended operating cycles (≤6 batches/day, ≥30 min cooldown between runs), the system exhibits a mean time between failures (MTBF) exceeding 12,000 hours for the heating module and 25,000 hours for the control electronics.