Empowering Scientific Discovery

HORIBA F-71 Benchtop pH and ORP Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HORIBA
Origin Japan
Model F-71
Instrument Type Laboratory Water Quality Analyzer
Measured Parameters pH, ORP, Temperature
pH Range 0.000–14.000
pH Resolution 0.001
pH Repeatability ±0.005 pH ±1 digit
ORP Range ±1999.9 mV
ORP Resolution 0.1 mV
ORP Repeatability ±0.1 mV ±1 digit
Temperature Range 0.0–100.0 °C (–30.0 to 130.0 °C)
Temperature Resolution 0.1 °C
Temperature Repeatability ±0.1 °C ±1 digit
Data Storage Capacity 999 entries
Power Supply AC adapter, 100–240 V, 50/60 Hz
Power Consumption ~0.7 VA
Weight ~500 g

Overview

The HORIBA F-71 is a precision-engineered benchtop pH and ORP analyzer designed for rigorous laboratory environments where trace-level accuracy, operational consistency, and regulatory traceability are essential. Built upon HORIBA’s decades of electrochemical sensor expertise, the F-71 implements potentiometric measurement principles using high-stability glass pH electrodes and noble-metal reference systems to deliver metrologically sound pH and redox potential data. Its core architecture supports three primary measurements—pH, oxidation-reduction potential (ORP), and temperature—each acquired via calibrated analog-to-digital conversion with auto-compensated thermal referencing. Unlike portable or process-oriented meters, the F-71 is purpose-built for static, high-integrity laboratory workflows: method validation, QC release testing, stability studies, and raw material qualification in pharmaceutical, academic, and environmental research settings. Its design reflects strict adherence to foundational electrochemical standards—including JIS Z 8802, ASTM D1293, and ISO 10523—and provides the foundational measurement integrity required for downstream compliance with USP , EP 2.2.3, and JP General Chapter 2.21.

Key Features

  • Capacitive touchscreen interface with intuitive navigation—enables full parameter configuration, real-time diagnostics, and on-screen troubleshooting without external software.
  • Integrated electrode health monitoring and guided calibration wizard compliant with JIS, USP, EP, JP, and CP pharmacopoeial protocols.
  • Single-channel measurement architecture optimized for pH, ORP, and temperature—minimizes cross-parameter interference and simplifies method documentation.
  • Thermal compensation algorithm with automatic temperature sensing (0.0–100.0 °C range; extended capability to –30.0 °C and 130.0 °C) ensures accurate pH reporting across wide ambient and sample conditions.
  • Robust mechanical design: lightweight (500 g) yet lab-grade housing with integrated electrode holder, low-power consumption (~0.7 VA), and universal AC input (100–240 V, 50/60 Hz).
  • GLP-compliant data handling: timestamped measurements stored locally (999 records), with USB port for secure export to LIMS or validated analysis platforms.

Sample Compatibility & Compliance

The F-71 is compatible with standard combination pH/ORP electrodes featuring Ag/AgCl reference systems and low-resistance glass membranes suitable for aqueous samples ranging from ultrapure water (≥18.2 MΩ·cm) to buffered saline solutions and mildly aggressive industrial effluents. Electrode compatibility extends to HORIBA’s proprietary LAQUAtwin series and third-party ISO 8655-compliant sensors. Regulatory alignment includes built-in support for pharmacopeial water testing workflows: conductivity-derived TDS, salinity, and resistivity calculations follow USP and EP 2.2.39 conventions when paired with appropriate conductivity modules (note: F-71 does not include conductivity hardware—this functionality is available in higher-tier F-72/F-74 models). All measurement logs retain audit-ready metadata (operator ID, calibration history, electrode serial number, ambient temperature), satisfying FDA 21 CFR Part 11 requirements when used within a validated computer system environment.

Software & Data Management

Data acquisition and management are handled through the instrument’s embedded firmware—not cloud-dependent or subscription-based. Each measurement is stamped with date, time, temperature, electrode status, and calibration verification flags. The USB interface supports direct file transfer of CSV-formatted datasets for integration into Excel, MATLAB, or validated laboratory informatics systems. While the F-71 does not feature onboard multi-language UI beyond English and Japanese (Chinese/Korean language support begins at F-72), its firmware architecture enables seamless synchronization with HORIBA’s optional LabX® Lite software for centralized instrument fleet management, electronic signature capture, and automated report generation. Audit trails are retained in non-volatile memory and cannot be altered post-recording—critical for GLP/GMP-aligned laboratories undergoing internal or regulatory inspection.

Applications

The F-71 serves as a foundational tool in quality control laboratories performing routine pH verification of purified water systems (PW, WFI), buffer preparation, titration endpoint confirmation, and stability-indicating assays. It is routinely deployed in university teaching labs for electrochemistry instruction, municipal water treatment facilities for compliance sampling (e.g., EPA Method 150.1), and R&D centers validating novel ion-selective sensor materials. Its repeatability (±0.005 pH) and resolution (0.001 pH) make it suitable for applications requiring detection of subtle acid-base shifts—such as enzymatic reaction monitoring, corrosion inhibitor evaluation, and dissolution profile development per USP . When paired with certified reference materials (NIST-traceable buffers), the F-71 meets the performance criteria for Tier 2 analytical instrumentation under ISO/IEC 17025:2017 Clause 6.4.

FAQ

Does the F-71 support conductivity or TDS measurements?
No—the F-71 is a dedicated pH/ORP/temperature analyzer. Conductivity, resistivity, salinity, and TDS capabilities require the F-72, F-73, or F-74 models, which integrate dual-electrode AC conductivity cells and associated calculation engines.
Is the F-71 compliant with FDA 21 CFR Part 11?
The device itself provides Part 11–ready data integrity features (electronic signatures, audit trails, immutable storage); full compliance requires implementation within a validated IT infrastructure, including controlled user access, electronic record retention policies, and periodic system verification.
Can I use non-HORIBA electrodes with the F-71?
Yes—any BNC-terminated pH/ORP electrode meeting IEC 60746-1 electrical specifications (impedance ≤ 10¹² Ω, offset voltage ≤ ±30 mV) is functionally compatible, though HORIBA-certified electrodes ensure optimal calibration stability and diagnostic feedback.
What is the recommended calibration frequency?
Per USP , daily calibration is advised for critical applications; for routine QC, calibration before each analytical batch—verified against two-point (4.01 and 7.00 or 10.01) NIST-traceable buffers—is standard practice.
Does the F-71 include printer connectivity?
No—printer support (via RS-232 or USB thermal printers) is available only on F-72/F-74 models equipped with dual-channel I/O and GLP/GMP output modes.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0