HORIBA
Filter
Showing 1–30 of 676 results
| Brand | HORIBA |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DeltaRAM™ X |
| Light Source Type | High-Intensity Xenon Arc Lamp |
| Illumination Mode | Internal (Epi/Illuminator-Coupled) |
| Excitation Wavelength Range | 250–650 nm |
| Wavelength Switching Speed | < 2 ms |
| Beam Uniformity | < 5% |
| Stray-Light Rejection | 10⁻⁴ |
| Wavelength Accuracy | ±1 nm |
| Optical Output | 15 mW (in 10 nm bandwidth) |
| Bandwidth Adjustment | 0–24 nm (manually adjustable slit) |
| Coupling | 2 m Liquid Light Guide included |
| Brand | HORIBA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | Evaluator HT Series |
| Pricing | Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Flex-CLUE |
| Pricing | Available Upon Request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 0030-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Sensor Type | Integrated Silicon-based Ion-Sensitive Field-Effect Transistor (ISFET) |
| Tip Geometry | Flat-ended needle tip |
| Tip-to-Sleeve Gap | < 100 µm |
| Electrode Body Material | Chemically resistant polymer |
| Storage | Dry storage compatible (no KCl solution immersion required) |
| Compliance | Designed for GLP/GMP-aligned workflows, compatible with ASTM D1293 and ISO 3696 Grade 3 water monitoring protocols |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 0040-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Solid-State ISFET (Ion-Sensitive Field-Effect Transistor) |
| Sensing Surface | Flat-tip, <100 µm gap between sensor surface and protective sleeve |
| Compliance | Designed for GLP/GMP-relevant environments |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 1512-10C |
| Measuring Range | 2.3–230,000 ppm Na⁺ |
| Compatible Reference Electrode | 2565A |
| Catalog Number | 3014068526 (9003016700) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3551-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 µS/cm to 1 S/cm (0.1 µS/cm to 10 mS/cm) |
| Minimum Sample Volume | 50 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014081712 (9056000800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3551-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 µS/cm to 1 S/cm (0.1 µS/cm to 10 mS/cm) |
| Minimum Sample Volume | 50 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014081712 (9056000800) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3561-10D |
| Cell Constant | 10 m⁻¹ (0.1 cm⁻¹) |
| Conductivity Range | 10 μS/cm to 1 S/cm (0.1 μS/cm to 10 mS/cm) |
| Minimum Sample Volume | 10 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014082350 (Legacy: 9056001100) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 3562-10D |
| Conductivity Range | 0.1 mS/cm to 10 S/cm (1 µS/cm to 100 mS/cm) |
| Cell Constant | 100 m⁻¹ (1 cm⁻¹) |
| Minimum Sample Volume | 16 mL |
| Operating Temperature Range | 0–60 °C |
| Part Number | 3014082513 (Legacy: 9056001200) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 4163-10T |
| Temperature Range | 0–100 °C |
| Compatibility | Designed for use with HORIBA pH/ORP meters (e.g., LAQUA series) and compatible third-party analyzers requiring Pt1000 or analog temperature input |
| Output Signal | Analog (2-wire RTD, Pt1000 class B per IEC 60751) |
| Enclosure Material | Chemically resistant PPS (polyphenylene sulfide) body with stainless steel tip |
| Cable Length | 1 m standard (custom lengths available) |
| IP Rating | IP67 |
| Calibration Traceability | NIST-traceable reference data provided upon request |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6560-10C |
| Measurement Range | 0.4–35,000 ppm Cl⁻ |
| Electrode Type | Composite (Integrated Reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW, D-53 |
| Catalog No. | 3014093430 (Legacy: 9003014500) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6561-10C |
| Measurement Range | 0.02–19,000 ppm F⁻ |
| Electrode Type | Composite (integrated reference), no external reference electrode required |
| Compatible Instruments | HORIBA F-72, F-73, F-74, F-74BW (benchtop) |
| Compliance | Designed for ASTM D1179, ISO 10304-1, and EPA Method 300.0 applications in water quality testing |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6581-10C |
| Measuring Range | 0.62–62,000 ppm NO₃⁻ |
| Electrode Type | Composite (integrated reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW (benchtop) |
| Interference Consideration | Performance affected by pH and coexisting ions (e.g., Cl⁻, SO₄²⁻, HCO₃⁻) |
| Part Number | 3014093432 (legacy: 9003014700) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6582-10C |
| Measurement Range | 0.04–39,000 ppm K⁺ |
| Electrode Type | Composite (Integrated Reference) |
| Compatible Meters | HORIBA F-72 / F-73 / F-74 / F-74BW (benchtop), D-53 (portable) |
| Reference System | Built-in double-junction Ag/AgCl reference |
| Operating pH Range | 2.5–10.5 (K⁺-specific membrane unaffected by common interferents within this range) |
| Response Time | <30 seconds (t₉₀ in standard calibration solutions) |
| Temperature Range | 0–50 °C |
| Storage Solution | 0.1 M KCl or manufacturer-recommended storage buffer |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 6583-10C |
| Measuring Range | 0.4–40,080 ppm Ca²⁺ |
| Electrode Type | Composite ISE (Integrated Reference) |
| Compatible Instruments | F-72, F-73, F-74, F-74BW (benchtop) |
| Catalog No. | 3014093434 (9003014900) |
| Interference Consideration | pH range and coexisting ions affect measurement accuracy |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8002-10C |
| Measuring Range | 0.4–35,000 ppm Cl⁻ |
| Reference Electrode | 2565A |
| Part Number | 3014094394 (9003015600) |
| Compatible With | F-72/F-73/F-74/F-74BW Benchtop Analyzers, D-53 Portable Analyzer |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8010-10C |
| Measuring Range | 0.02–19,000 ppm F⁻ |
| Compatible Reference Electrodes | 2060A & 2565A |
| Part Number | 3014093439 (9003016400) |
| Compliance | Designed for ASTM D1179, ISO 10304-1, and EPA Method 300.0 applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8201-10C |
| Measuring Range | 0.62–62,000 ppm NO₃⁻ |
| Reference Electrode | 2565A |
| Part Number | 3014094403 (9003016800) |
| Compatible Meters | F-72, F-73, F-74, F-74BW, D-53 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8202-10C |
| Measuring Range | 0.04–39,000 ppm K⁺ |
| Reference Electrode | 2565A |
| Electrode Type | Non-Composite, Replaceable Sensing Element Design |
| Compliance | Designed for ASTM D1293, ISO 10523, and EPA Method 9055B applications |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 8203-10C |
| Measuring Range | 0.4–40,080 ppm Ca²⁺ |
| Compatible Reference Electrodes | 2060A and 2565A |
| Part Number | 3014068839 (9003017000) |
| Compliance | Designed for ASTM D511, ISO 10523, and EPA Method 300.0-compatible water analysis workflows |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Electrode Type | Waterproof Pt/Ag-AgCl Composite ORP Electrode |
| Body Material | Titanium |
| Output Signal | mV (vs. Standard Hydrogen Electrode) |
| Compatibility | Designed for standalone ORP measurement only — not to be used concurrently with pH or other reference electrodes |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Type | Composite Redox Electrode (Pt/Ag-AgCl Reference) |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Body Material | Waterproof Glass |
| Electrode Configuration | Integrated Pt Sensing Element + Double-Junction Ag/AgCl Reference |
| Compatibility | Aqueous Solutions, Wastewater, Industrial Process Streams |
| Electrical Connection | BNC |
| IP Rating | IP67 (when capped) |
| Calibration Support | Single-point or multi-point ORP standard verification (e.g., ±200 mV, +450 mV Zobell’s solution, +220 mV saturated quinhydrone) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9300-10D |
| Temperature Range | 0–60 °C |
| Electrode Type | Waterproof Pt-based composite redox electrode |
| Compatibility | Designed for standalone ORP measurement (not to be used simultaneously with pH or other reference electrodes) |
| Compliance | Engineered for routine electrochemical monitoring in accordance with ISO 10523, ASTM D1293, and EPA Method 150.1 |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-100D |
| Cable Length | 10 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Electrode Type | Clark-type polarographic DO sensor |
| Compatibility | Designed for use with HORIBA LAQUA DO meters (e.g., LAQUA twin, LAQUA DO-110/210 series) |
| Calibration | Two-point (zero O₂ and air-saturated water) or single-point (air-saturation) |
| Response Time (t₉₀) | < 30 s in stirred water |
| Membrane | Replaceable Teflon® (PTFE) cap |
| Electrolyte | KCl-based aqueous electrolyte |
| Storage Condition | Wet storage in DO electrode storage solution or saturated KCl solution |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9551-20D |
| Cable Length | 2 m |
| Operating Temperature Range | 0–40 °C |
| IP Rating | IP68 (submersible) |
| Compatibility | Designed for use with HORIBA portable and benchtop DO meters (e.g., D-55, LAQUA twin series, or compatible analog input systems) |
| Electrode Type | Polarographic (Clark-type), membrane-covered, galvanic cell configuration |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D / 9625-10D |
| Construction | Integrated Glass pH Sensor, Reference Electrode, and Pt1000 Temperature Sensor |
| Body Material | 9615-10D — Glass Shaft |
| Membrane Type | ToupH Thick-Film Glass (9615-10D) |
| Internal Electrolyte | KCl 3.0 mol/L (Ref. #300) |
| Application Focus | Municipal drinking water, ultrapure water, low-buffered samples, field-deployable environmental monitoring |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615-10D |
| Temperature Range | 0–100 °C |
| pH Range | 0–14 |
| Compliance | ISO 3696 (Grade 2 water), ASTM D1293, USP <791>, JIS Z 8802 |
| Electrode Type | Integrated Glass pH Sensor + Ag/AgCl Reference + Pt ORP Element + NTC Thermistor |
| Body Material | Chemically Resistant PPS Plastic |
| Tip Geometry | Flat-Surface Ceramic Junction with Sub-100 µm Guard Gap |
| Response Time (t₉₀) | ≤15 s (pH 4 → 7 → 10 buffer transition, 25 °C) |
| Drift | <0.01 pH/h (24 h, stable electrolyte fill) |
| Mechanical Strength | >10× JIS R 3201 (Glass Electrode Impact Resistance Standard) |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9615S-10D |
| pH Range | 0–14 |
| Temperature Range | 0–100 °C |
| Temperature Sensor | Integrated Pt1000 or NTC (configurable) |
| Cable Length | 1 m |
| Connector | BNC + Phono (RCA) |
| Overall Length | 151 mm |
| Diameter | 12 mm |
| Fill Solution | 3.33 M KCl (HORIBA Ref. 525-3 or 300) |
| Construction | Lead-free thick-film glass membrane, waterproof IP67-rated body |
| Electrode Type | Refillable combination electrode |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | 9618-10D |
| Temperature Range | 0–60 °C |
| pH Range | 0–14 |
| Electrode Type | Combination pH Electrode with Flat-tip ISFET-enhanced Glass Membrane |
| Compliance | JIS Z 8802 (pH electrode performance), ISO 7888 (water quality — pH determination) |
| Enclosure Material | Chemically resistant PPS body |
| Tip Geometry | Hemispherical + flat-surface sensing zone |
| Reference System | Cation-conductive hollow-fiber junction |
| Response Time (t₉₀) | ≤15 s (typical, at 25 °C, ΔpH = 1.0) |
| Mechanical Strength | >10× JIS Z 8802 specified impact resistance |