Empowering Scientific Discovery

ATAGO PAL-37S Isopropyl Alcohol (IPA) Digital Handheld Refractometer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand ATAGO
Origin Japan
Product Type Handheld Refractometer
Model PAL-37S
Measurement Range 0.0–60.0% IPA (w/w)
Accuracy ±0.6% (0–30%), ±1.6% (40–60%)
Temperature Range 10–40°C with Automatic Temperature Compensation (ATC)
Resolution 0.2%
Display Digital LCD
Power Supply Two AAA batteries
IP Rating IP65
Dimensions 5.5 × 3.1 × 10.9 cm
Weight 100 g (instrument only)

Overview

The ATAGO PAL-37S Isopropyl Alcohol (IPA) Digital Handheld Refractometer is a precision optical instrument engineered for rapid, on-site quantification of isopropyl alcohol concentration in aqueous solutions. It operates on the principle of critical-angle refractometry: light passing through a prism-sample interface undergoes refraction proportional to the solution’s refractive index, which correlates directly with IPA mass fraction under controlled temperature conditions. The PAL-37S is factory-calibrated using NIST-traceable IPA reference standards and incorporates ATAGO’s proprietary Automatic Temperature Compensation (ATC) algorithm, compensating for thermal drift across the 10–40°C operating range without requiring external thermostatic control. Unlike generic refractometers, the PAL-37S employs a dedicated calibration curve optimized specifically for the non-linear refractive behavior of IPA–water mixtures—ensuring metrological integrity where conventional Brix or ethyl alcohol scales fail. Its compact, single-hand operation supports real-time process verification in cleanrooms, pharmaceutical manufacturing lines, electronics cleaning validation, and laboratory QC workflows where traceability, repeatability, and minimal sample volume (<0.3 mL) are critical.

Key Features

  • Optimized optical path design with high-stability sapphire prism for long-term refractive index stability and chemical resistance to IPA and common solvents
  • Digital LCD display with 0.2% resolution and automatic unit indication (%, w/w), eliminating manual conversion errors
  • True ATC functionality compliant with ISO 21748:2017 guidelines for temperature-dependent measurement correction
  • Rugged housing rated IP65 per IEC 60529, providing dust-tight protection and resistance to low-pressure water jets—suitable for industrial floor environments
  • Low-power architecture enabling >10,000 measurements per set of two AAA alkaline batteries
  • Zero-point calibration function accessible via dedicated key sequence, supporting field recalibration against certified IPA standards

Sample Compatibility & Compliance

The PAL-37S is validated exclusively for homogeneous, non-viscous, non-suspended isopropyl alcohol–water solutions at ambient pressure. It is not intended for use with glycol blends, surfactant-laden cleaners, or solutions containing particulates, oils, or high-molecular-weight polymers, as these introduce scattering artifacts and refractive index deviations beyond the instrument’s compensation model. All measurements comply with ASTM D1152–19 (Standard Specification for Isopropyl Alcohol) for concentration verification in technical-grade IPA. The device meets GLP documentation requirements when used with traceable calibration records and operator log entries; its firmware maintains no internal audit trail, so external recordkeeping is required for FDA 21 CFR Part 11–aligned environments.

Software & Data Management

The PAL-37S is a standalone, embedded-system instrument with no Bluetooth, USB, or wireless connectivity. Measurement data remain local to the LCD display and are not stored internally. For integration into LIMS or electronic batch records, users must manually transcribe values or employ optional third-party digital capture tools (e.g., smartphone-based OCR applications validated per ISO/IEC 17025). ATAGO provides downloadable calibration certificates and reference material datasheets (Cat. No. 4437) supporting metrological traceability to JCSS (Japan Calibration Service System). Firmware updates are not field-upgradable; hardware revision control is maintained via serial number and date code etching on the rear housing.

Applications

  • Final rinse verification in semiconductor wafer cleaning processes where residual IPA must be confirmed below 50 ppm (via dilution-series correlation)
  • In-process concentration monitoring during IPA-based degreasing bath replenishment in medical device manufacturing
  • Raw material receipt inspection for USP/EP-grade isopropyl alcohol in pharmaceutical excipient handling
  • Field validation of IPA disinfectant solutions in healthcare facility environmental services
  • Educational laboratory exercises demonstrating colligative property relationships and refractive index calibration curves

FAQ

Does the PAL-37S require periodic recalibration?
Yes—ATAGO recommends annual recalibration using certified IPA reference standards (e.g., 10.0%, 30.0%, and 50.0% w/w), especially after mechanical shock or exposure to temperatures outside 10–40°C.
Can it measure denatured alcohol or ethanol–IPA blends?
No—the calibration curve is specific to pure IPA–water systems. Ethanol or denaturants alter the refractive index non-linearly and invalidate results.
Is the sapphire prism replaceable in the field?
No—prism replacement requires factory service due to optical alignment sensitivity and hermetic sealing requirements.
What does IP65 rating mean for daily use?
It certifies full dust ingress protection and resistance to water projected from a 6.3 mm nozzle at 12.5 L/min for 3 minutes—enabling safe use near sinks, spray stations, or humidified cleanroom corridors.
Why is accuracy specified differently across ranges (±0.6% vs. ±1.6%)?
Refractive index linearity degrades above 30% IPA concentration; the expanded uncertainty reflects empirical validation per ISO/IEC 17025 method validation protocols.