Peak Scientific Precision Hydrogen Trace 500cc Hydrogen Generator

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PEAK
Origin United Kingdom
Manufacturer Type Original Equipment Manufacturer (OEM)
Import Status Imported
Model Precision Hydrogen Trace 500cc
Hydrogen Generation Principle PEM Electrolysis of Deionized Water
Output Flow Rate 500 cc/min
Output Pressure 0–100 psi (0–6.9 bar)
Hydrogen Purity 99.9999% (6.0 N)
Dew Point < –70 °C (< 1 ppmv H₂O)
Power Consumption 1380 W
Dimensions (H×W×D) 440 × 320 × 500 mm
Weight 28 kg
Safety Certifications CE, UKCA, UL/CSA 61010-1, IEC 62368-1

Overview

The Peak Scientific Precision Hydrogen Trace 500cc Hydrogen Generator is an engineered solution for laboratories requiring ultra-high-purity hydrogen gas as a carrier or fuel gas in gas chromatography (GC), GC–MS, and other analytical instrumentation. Designed around proton exchange membrane (PEM) electrolysis technology, it generates hydrogen on-demand from deionized water—eliminating the logistical, safety, and regulatory burdens associated with high-pressure cylinder storage. The system delivers continuous, stable flow at up to 500 cc/min with guaranteed purity of 99.9999% (6.0 N), trace moisture content below 1 ppmv, and oxygen impurity < 0.1 ppmv—meeting stringent requirements for sensitive detectors such as flame ionization (FID), thermal conductivity (TCD), and pulsed discharge helium ionization (PDHID). Its compact, stackable chassis supports modular deployment across multi-instrument labs while maintaining full compliance with IEC 61010-1 and IEC 62368-1 for laboratory electrical safety.

Key Features

  • PEM-based electrolysis core ensures rapid start-up, zero hydrocarbon contamination, and intrinsic safety via low-pressure internal generation (no high-pressure storage vessels)
  • Integrated dual-stage purification: catalytic recombination followed by molecular sieve drying delivers <1 ppmv H₂O and <0.1 ppmv O₂
  • Real-time status monitoring via intuitive LED interface with color-coded indicators for operational state, maintenance alerts, and fault diagnostics
  • Auto-shutdown and leak detection circuitry compliant with EN 60079-10-1 for hazardous area considerations
  • Low-maintenance architecture: only annual desiccant replacement and biannual deionized water cartridge change required under normal operation
  • Front-access service design enables field-replaceable modules without tools—minimizing downtime during scheduled PM

Sample Compatibility & Compliance

The Precision Hydrogen Trace 500cc is validated for use with all major GC platforms including Agilent 7890/8890, Thermo Fisher TRACE 1300/1600, Shimadzu GC-2030, and PerkinElmer Clarus series. It meets ASTM D6299 and ISO 8573-1 Class 1 compressed gas quality specifications for instrumental analysis. All firmware and hardware configurations adhere to FDA 21 CFR Part 11 requirements for electronic records and signatures when paired with optional PeakConnect™ software. Full GLP/GMP documentation packages—including IQ/OQ protocols, calibration certificates, and traceable material declarations—are available upon request for regulated environments in pharmaceutical QC, food safety testing, and environmental monitoring laboratories.

Software & Data Management

PeakConnect™ software (optional) provides remote monitoring, event logging, and audit-trail-enabled data export compatible with LIMS integration. System logs record runtime hours, pressure transients, temperature profiles, and consumables usage—supporting predictive maintenance scheduling per ISO/IEC 17025 Clause 6.4.2. Firmware updates are delivered via secure HTTPS channel with SHA-256 signature verification. All data storage complies with GDPR Article 32 technical safeguards; no telemetry or cloud transmission occurs unless explicitly enabled by user configuration.

Applications

  • Carrier gas supply for capillary GC and GC–MS systems requiring ultra-low background interference
  • Fuel gas for FID and FTIR-based combustion analyzers in petrochemical and emissions testing
  • Reduction atmosphere generation in thermal desorption units and purge-and-trap concentrators
  • Calibration gas blending support in certified reference material (CRM) preparation workflows
  • On-site hydrogen sourcing for portable GC systems deployed in field environmental sampling

FAQ

What water quality is required for optimal operation?
Deionized water with resistivity ≥ 15 MΩ·cm and total organic carbon (TOC) < 5 ppb is mandatory. Integrated water quality sensor triggers audible/visual alerts if conductivity exceeds 0.5 µS/cm.
Can this generator supply multiple GC instruments simultaneously?
Yes—when configured with Peak’s Multi-Port Distribution Manifold (optional), the unit supports up to three independent GC lines with individual pressure regulation and flow metering.
Is the system compatible with nitrogen-purged GC oven enclosures?
Yes—the generator’s sealed electronics and non-sparking enclosure meet IP54 ingress protection standards and operate safely within nitrogen-enriched ambient environments.
How often must consumables be replaced?
The deionized water cartridge requires replacement every 6 months; the desiccant column every 12 months—both intervals are tracked automatically and reported via front-panel display and PeakConnect™.
Does the generator require external cooling or ventilation?
No—passive convection cooling suffices. Ambient operating temperature range is 15–30 °C; no forced-air exhaust or dedicated HVAC ducting is needed.