Empowering Scientific Discovery

PerkinElmer GC 2400™ Platform with Split Touchscreen – Gas Chromatography-Mass Spectrometry System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand PerkinElmer
Origin USA
Manufacturer Type Original Equipment Manufacturer (OEM)
Origin Category Imported Instrument
Model GC 2400
Instrument Type Laboratory Gas Chromatograph-Mass Spectrometer
Application Scope General-Purpose GC-MS Analysis
Key Feature Integrated Split Touchscreen Control Interface
Detection Technology Quadrupole Mass Spectrometry (MS 2400 SQ) with Clarifi™ Detector
Sample Introduction Smart Liquid Autosampler with Pressure-Balanced Injection
Safety System Integrated Hydrogen Sensor
Source Technology SMARTsource™ Replaceable Ion Source
Software Platform Simplicity™ GC/MS Workstation

Overview

The PerkinElmer GC 2400™ Platform is a purpose-engineered gas chromatography–mass spectrometry (GC-MS) system designed for robust, high-throughput laboratory environments requiring regulatory compliance, method reproducibility, and operational flexibility. Built upon a modular architecture, the platform integrates a high-performance capillary GC module with the MS 2400 SQ quadrupole mass spectrometer—featuring the Clarifi™ detector for enhanced signal-to-noise ratio and improved low-abundance ion detection. The system employs electron ionization (EI) and optional chemical ionization (CI) modes, supporting both targeted quantitation and untargeted screening workflows. Its pressure-balanced injection technology ensures precise, pulse-free sample introduction across volatile and semi-volatile compounds, minimizing carryover and improving retention time stability. Designed for routine analysis in environmental, pharmaceutical, food safety, and forensic laboratories, the GC 2400 platform meets core performance requirements aligned with ASTM D5845, ISO 17025, USP , and EPA Methods 8270/8260.

Key Features

  • Split touchscreen interface enabling remote instrument control, real-time diagnostics, and contextual workflow guidance without requiring dedicated PC proximity
  • SMARTsource™ ion source design—tool-free, hot-swap replacement in under 90 seconds—minimizing downtime and maintaining consistent ionization efficiency across extended run sequences
  • Pressure-balanced liquid injection system delivering sub-microliter precision, reduced thermal degradation of thermolabile analytes, and high reproducibility (<1.5% RSD for peak area over 100 injections)
  • Integrated hydrogen sensor with automatic shutoff and alarm logging—compliant with NFPA 55 and OSHA 1910.103 standards for safe H₂ carrier gas operation
  • Modular detector bay supporting rapid interchange between MS 2400 SQ, FID, or ECD configurations without recalibration or vacuum break
  • Simplicity™ GC/MS software featuring one-click method setup, automated tune optimization, and built-in spectral deconvolution algorithms for co-eluting peaks

Sample Compatibility & Compliance

The GC 2400 platform accommodates a broad range of sample matrices—including aqueous extracts, organic solvent dilutions, headspace vials, and thermal desorption tubes—via its configurable autosampler and programmable temperature-controlled inlet. It supports standard 10–100 µL liquid injections, split/splitless modes, cold on-column, and PTV (programmed temperature vaporizing) techniques. All hardware and firmware comply with IEC 61000-6-3 (EMC), UL 61010-1 (safety), and FDA 21 CFR Part 11 requirements when deployed with audit-trail-enabled software configuration. Full GLP/GMP traceability is supported through electronic signatures, version-controlled method storage, and immutable raw data archiving in .D format.

Software & Data Management

Simplicity™ GC/MS workstation provides a unified interface for instrument control, data acquisition, processing, and reporting. It includes embedded NIST Mass Spectral Search (v3.2), customizable report templates compliant with ISO/IEC 17025 Clause 7.8, and secure user role management (administrator, analyst, reviewer). Raw data files are stored in vendor-neutral, open-format HDF5 containers—ensuring long-term accessibility independent of software version. Integration with LIMS via ASTM E1578-compliant API enables automated sample queueing, result push, and QC flag propagation. Audit trails record all parameter changes, sequence edits, and reprocessing events with timestamp, operator ID, and reason-for-change fields.

Applications

The GC 2400 platform delivers validated performance across regulated and research-driven use cases: residual solvent analysis per ICH Q3C guidelines; pesticide multiresidue screening in food per EU SANTE/11312/2021; polycyclic aromatic hydrocarbon (PAH) profiling in soil per EPA 8270D; volatile organic compound (VOC) monitoring in indoor air per ISO 16000-6; and impurity identification in small-molecule APIs per USP . Its rapid method development capability—enabled by intelligent column oven ramp optimization and auto-tune feedback loops—reduces method transfer time by up to 40% compared to legacy platforms.

FAQ

Is the GC 2400 compatible with third-party columns and consumables?
Yes—the system accepts all standard 0.1–0.53 mm ID fused silica capillary columns with Agilent, Restek, and Thermo Scientific fittings. PerkinElmer-certified liners, septa, and guard columns are recommended for optimal performance and warranty coverage.
Can the MS 2400 SQ be upgraded to a high-resolution mass spectrometer?
No—the MS 2400 SQ is a fixed-resolution quadrupole system. For HRAM capabilities, PerkinElmer offers the TOF 2400 platform as a separate configuration.
Does the system support scheduled maintenance alerts and predictive diagnostics?
Yes—embedded health monitoring tracks filament emission current, vacuum integrity, detector gain drift, and injector seal wear. Alerts are logged in the Diagnostics Dashboard and can trigger email notifications via SMTP integration.
What data security protocols are implemented for network-connected operation?
All network communications use TLS 1.2+ encryption. Local data storage employs AES-256 full-disk encryption. Remote access requires multi-factor authentication (MFA) when enabled via enterprise Active Directory integration.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0