Empowering Scientific Discovery

Haier DW-60W156 Ultra Low Temperature Freezer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin USA
Manufacturer Type Authorized Distributor
Origin Category Imported
Model DW-60W156
Pricing Upon Request

Overview

The Haier DW-60W156 Ultra Low Temperature Freezer is an engineered solution for long-term cryogenic storage of biological specimens, reagents, vaccines, and temperature-sensitive materials at sustained -60 °C operating temperatures. Designed in accordance with international laboratory cold-chain standards, it employs a dual-stage cascade refrigeration architecture—comprising two independent compressors and optimized heat exchange circuits—to achieve stable thermal performance across ambient conditions ranging from 10 °C to 32 °C. Unlike single-stage systems, this configuration enables reliable operation at nominal -60 °C setpoints while maintaining internal uniformity within ±3 °C (measured per IEC 61000-4-2 spatial mapping protocol). The unit complies with UL 61010-1 and IEC 61010-2-011 safety requirements for laboratory equipment and meets structural design criteria referenced in ISO 13732-1 for surface temperature hazard mitigation.

Key Features

  • Dual-compressor cascade refrigeration system with non-ozone-depleting mixed refrigerants (R404A/R23 blend), engineered to reduce discharge pressure and improve thermal efficiency under high ambient loads
  • Double-door insulation structure with vacuum-insulated panels (VIPs) integrated into the outer door frame and high-density polyurethane foam (≥150 mm thickness, CFC/HCFC-free) in the cabinet walls
  • Microprocessor-based temperature controller with digital LED display, 1 °C resolution, adjustable setpoint range from -20 °C to -70 °C (achievable at 25 °C ambient)
  • Stainless steel interior chamber (304 grade) with seamless welded corners and rounded edges for ease of decontamination and thermal stability
  • Acoustic optimization yielding ≤55 dB(A) operational noise level at 1 m distance (per ISO 3744 test conditions)
  • Integrated mechanical door lock with key override; optional electronic access log available via external data interface
  • Two standardized 25 mm diameter test ports (one on each side wall) for real-time probe insertion or continuous monitoring integration

Sample Compatibility & Compliance

The DW-60W156 supports storage of primary human biospecimens (whole blood, PBMCs, serum, plasma), viral vectors, monoclonal antibodies, and small-molecule reference standards requiring thermal stability below -40 °C. Its chamber volume (156 L net) accommodates standard cryoboxes (e.g., 10×10 format), rack-based vial holders, and stacked sample trays without airflow obstruction. The unit conforms to Good Laboratory Practice (GLP) environmental control documentation requirements and supports audit-ready temperature logging when paired with validated external data loggers compliant with FDA 21 CFR Part 11 (electronic records and signatures). It is routinely deployed in blood bank facilities meeting AABB Standard 18.1.3 for frozen component storage and in clinical trial labs adhering to ICH-GCP Annex 11 data integrity guidelines.

Software & Data Management

While the base model operates via embedded firmware without proprietary software, the freezer includes RS-485 serial communication capability (Modbus RTU protocol) for integration into centralized laboratory infrastructure management systems (LIMS or BMS). Optional third-party validation packages support IQ/OQ/PQ documentation templates aligned with ISO/IEC 17025 and ASTM E2500-13. Temperature deviation alerts can be routed via dry-contact relay outputs to building alarm networks or SCADA platforms. All firmware updates are performed via secure USB interface with cryptographic signature verification to ensure traceability.

Applications

  • Long-term archival storage of hematopoietic stem cells and cord blood units in accredited cord blood banks
  • Cold-chain maintenance for mRNA vaccine intermediates during analytical method development and stability testing
  • Preservation of tissue sections and nucleic acid extracts in molecular pathology workflows
  • Storage of calibration standards and certified reference materials (CRMs) used in ISO/IEC 17025-accredited testing laboratories
  • Onboard refrigerated storage for marine research vessels conducting deep-sea bioprospecting missions

FAQ

What is the minimum ambient temperature required for stable -60 °C operation?
The unit achieves and maintains -60 °C setpoint at ambient temperatures as low as 10 °C, with full specification compliance verified between 15 °C and 32 °C.
Is the stainless steel interior electropolished?
No—the interior uses brushed-finish 304 stainless steel, selected for corrosion resistance, cleanability, and thermal mass consistency; electropolishing is available as a custom upgrade.
Can the unit be validated for GMP environments?
Yes—when equipped with calibrated NIST-traceable temperature sensors and connected to a Part 11–compliant data acquisition system, it supports formal qualification under EU Annex 15 and USP <1058>.
Does the freezer include a temperature mapping certificate?
Factory-installed mapping is not included by default but can be commissioned pre-shipment using IQ/OQ protocols executed by Haier-certified field service engineers.