- All
- Favorite
- Popular
- Most rated
| Brand | Chemplex |
|---|---|
| Origin | USA |
| Product Type | Imported Mylar® Polyester Film |
| Model | 106 |
| Thickness | 6.0 µm (0.24 mil) |
| Format | Pre-cut Circular Discs, Ø63.5 mm (2.5"), 500 pcs/box |
| Compliance | ASTM D882, ISO 527-3, USP <661.1>, RoHS-compliant |
| Application | X-ray Fluorescence (XRF), Energy-Dispersive X-ray Spectroscopy (EDX), Elemental Analysis Sample Support |
| Brand | VWR |
|---|---|
| Origin | USA |
| Model | 82019-170 |
| Speed | 2800 rpm (fixed) |
| Operating Mode | Continuous |
| Motion Type | Orbital (circular) |
| Amplitude | 4.5 mm |
| Display | Fixed-speed LED indication |
| Max Tube Diameter | 30 mm |
| Max Capacity | One 50 mL tube |
| Housing Material | Inert plastic upper casing and tube contact surface |
| Dimensions | 100 mm Ø × 70 mm H (4" × 2.75") |
| Operating Temperature Range | 5°C above ambient to 40°C |
| Weight | 0.55 kg |
| Electrical | 230 V, 50/60 Hz |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported Instrument |
| Model | UV-3100PC |
| Detector Type | CMOS Array |
| Wavelength Range | 190–1100 nm |
| Wavelength Scanning Mode | Automatic |
| Spectral Bandwidth | 2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Stray Light | ≤0.5% (at 220 nm and 340 nm) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Numbers | MTD5601-0801 / MTD5601-0400 |
| Pricing | Available Upon Request |
| Brand | VWR (Avantor) |
|---|---|
| Origin | USA |
| Model | 521-1651 |
| Type | Benchtop Centrifuge |
| Speed Range | 0–13,500 rpm |
| Max RCF | 12,300 × g |
| Capacity | 12 × 1.5/2.0 mL tubes |
| Rotor Type | Fixed-angle or swing-bucket compatible (standard configuration: 12-position fixed-angle rotor) |
| Dimensions (W×D×H) | 208 × 245 × 145 mm |
| Sterilization | Autoclavable rotor and bio-containment lid (121°C, 20 min) |
| Safety Features | Automatic lid lock/unlock, overspeed & overtemperature protection, short acceleration/deceleration profiles, optimized internal airflow for thermal management |
| Noise Level | <55 dB(A) at maximum speed |
| Compliance | CE, IEC 61010-1, ISO 13485 (manufacturing system), GLP-supportive design |
| Brand | VWR |
|---|---|
| Origin | USA |
| Construction | 6.35 mm (1/4") clear or bronze-tinted acrylic |
| Door | Gasketed, left-opening, 9.5 mm (3/8") acrylic with full-length hinges and stainless steel twist-lock latches |
| Trays | Removable, perforated, lipped, slide-in |
| Tray capacity | 2–4 adjustable vented shelves |
| Dimensions (H × W × D) | 18 × 18 × 25.4 cm (7 × 7 × 10 in), 23 × 23 × 40.6 cm (9 × 9 × 16 in), 30.5 × 30.5 × 30.5 cm (12 × 12 × 12 in), 45.7 × 30.5 × 30.5 cm (18 × 12 × 12 in) |
| Compliance | Designed for GLP-compliant storage environments |
| Origin | China |
|---|---|
| Manufacturer Type | Distributor |
| Product Category | Domestic |
| Model | 89032-098 |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | 61161-283 |
| Price | Upon Request |
| Accuracy | ±1°C (Model 61161-283) |
| Temperature Range | –50 to 300°C (–58 to 572°F) |
| Resolution | 0.1°C from –19.9 to 199.9°C, 1°C elsewhere |
| Probe Diameter × Length | 0.36 cm × 12.7 cm (0.14" × 5") |
| Unit Dimensions | 4.4 cm Ø × 1.3 cm D (1.73" Ø × 0.51" D) |
| Weight | 42.5 g (1.5 oz.) |
| Display | 6.4 mm high LCD digits |
| Update Interval | 1 second |
| Housing | Waterproof and shockproof |
| Probe Material | Stainless steel sensor |
| Calibration | ISO/IEC 17025-accredited certificate traceable to NIST standards |
| Power | 1.5 V silver-oxide battery (1 year continuous operation) |
| Accessories | 3 m probe cable, magnet mount, suction cups, Velcro® fastener |
| Brand | VWR |
|---|---|
| Origin | USA |
| Filter Grades | 691, 693, 696, GF/A, 934-AH |
| Diameter Range | 2.1–30.5 cm |
| Particle Retention | 1.1–1.6 µm |
| Porosity | Fine |
| Max Operating Temperature | 550 °C |
| Basis Weight | 64 g/m² |
| Filtration Speed | 47 sec/100 mL (Herzberg) |
| Brand | VWR |
|---|---|
| Origin | USA |
| Product Line | Sterile Disposable Sampling Containers |
| Models | 82007-714, 83007-556, 83007-562, 89000-190 |
| Sterility | Gamma-Irradiated (SAL 10⁻⁶) |
| Material | Low-Density Polyethylene (LDPE) |
| Max Temp | 100°C (212°F) |
| Not Compatible With | Alcohols or Strong Oxidizers |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | T_701FBT10P |
| Instrument Type | Electric Handheld Homogenizer |
| Max. Sample Volume | 0.5–100 mL |
| Speed Range | 8,000–30,000 rpm |
| Temperature Control | Not integrated |
| Brand | VWR |
|---|---|
| Origin | USA |
| Distributor Type | Authorized Distributor |
| Import Status | Imported |
| Model | 3500 |
| Instrument Category | Orbital Shaker |
| Platform Quantity | 5 |
| Orbit Diameter | 0.75 in |
| Timer Range | Not Available |
| Oscillation Frequency | Not Specified |
| Temperature Control | Not Integrated |
| Pricing Range | USD 1,400 – 2,800 (est. based on FOB US market) |
| Brand | VWR |
|---|---|
| Origin | USA |
| Model | 634-6001 |
| Optical System | Single-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 4 nm |
| Wavelength Accuracy | ±2 nm |
| Stray Light | ≤0.05% T |
| Wavelength Repeatability | ≤0.3 nm |
| Photometric Accuracy | ±0.3% T |
| Photometric Range | 0–200% T, –0.3 to 3.0 A |
| Baseline Stability | ±0.002 A/h at 500 nm |
| Display | 128 × 64 dot-matrix LCD |
| Interface | USB |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MTD5600-1502 / MTD5600-0501 |
| Pricing | Available Upon Request |
| Material | Polypropylene (PP) |
| Discharge Tube Options | Fixed PP or Adjustable 1.25 m PVC with Faucet |
| Sealing | PTFE Gasket |
| Immersion Tube ID | 32 mm |
| Max Flow Rate | ~12 L/min |
| Compatible Drum Capacity | 60–1000 L |
| Connection | Threaded Sleeve Coupling |
| Immersion Depth Adjustment | Continuously Variable |
| Residual Liquid Minimization | Low-Position Check Valve |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MTD5606-1000 |
| Pricing | Available Upon Request |
| Brand | VWR |
|---|---|
| Origin | USA |
| Model | 89176-484 |
| Voltage | 230 V, 50 Hz |
| Dimensions (W×D×H) | 35.6 × 45.9 × 33 cm |
| Maximum Capacity | 4 × 100 mL |
| Maximum RCF | 17,320 × g |
| Speed Range | 250–13,500 rpm |
| Weight | 39.9 kg |
| Rotor Recognition | Yes |
| Braking Control | Dynamic soft-stop |
| Motor Type | Brushless DC |
| Timer Modes | Timed / Continuous / Momentary |
| Compliance | CE, IEC 61010-1, UL 61010-1 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DW-40L262 |
| Pricing | Available Upon Request |
| Brand | VWR |
|---|---|
| Origin | USA |
| Model | VWRI630-3292 |
| Microscope Type | Upright |
| Head Type | Trinocular |
| Eyepiece | Widefield 10×/18 mm |
| Objective Lenses | N-plan HC 4×, 10×, 40×, 60× (standard configuration) |
| Stage | 125 × 115 mm mechanical stage with 70 × 30 mm travel range |
| Condenser | Abbe condenser, NA 1.25, pre-centered, height-adjustable, with iris diaphragm |
| Focusing System | Coaxial coarse and fine focus knobs (fine focus graduation: 2 µm) |
| Illumination | 3 W LED Köhler illumination, color temperature ~6,000 K, >50,000 h lifetime |
| Dimensions (W × D × H) | 235 × 290 × 370 mm |
| Weight | 6.5 kg |
| Compliance | CE, UKCA, ISO 9001-manufactured supply chain, RoHS-compliant components |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | 613-5250 |
| Instrument Type | Multichannel Pipette |
| Automation Level | Electronic |
| Channel Count | 12-channel |
| Volume Range | 1–10 µL |
| Accuracy | ±8.0% to ±2.0% |
| Precision (CV) | <8.0% to <2.0% |
| Sterilization | Autoclavable (121°C, 20 min) |
| Compliance | ISO 8655-2:2022, ISO 8655-6:2022, GLP/GMP-ready |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MYL-D1076 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MHV-97025-100 |
| Max RCF | 5000 × g |
| Max Speed | 9200 rpm |
| Speed Settings | 6000 rpm (2000 × g) / 9200 rpm (5000 × g) |
| Timer Range | 1–15 min, Pulse Mode, Continuous Mode |
| Rotor Compatibility | 8-place fixed-angle rotor (1.5 mL), 4-place rotor (5 mL), PCR strip rotor (0.2 mL), eight 0.5 mL tube adapters |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 620-1582 |
| Price | Upon Request |
| Accuracy | ±0.5 °C |
| Temperature Range | −50 to +70 °C |
| Resolution | 0.1 °C |
| Dimensions (W×D×H) | 75 × 62 × 15 mm |
| Weight | 113 g |
| Probe Options | Ethylene Glycol-filled Bottle Sensor (620-1582) or Stainless Steel Bullet Probe (20 mm, 620-1583) |
| Calibration Points | 0 °C and 50 °C |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | OLS200 / 66238-204 |
| Pricing | Upon Request |
| Brand | VWR |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported PPE |
| Model Numbers | 1013461 / 89013-671 / 138-3015085 / 300061-684 |
| Noise Reduction Rating (NRR) | 22–30 dB |
| Weight | 0.58–0.62 lb |
| Configuration Options | Folding Headband, Neckband, Cap-Mounted, Standard Headband |
| Compliance | ANSI S3.19-1974, CSA Z94.2-14, EN 352-1:2019 |
| Packaging | Case of 20 units (per model) |
| Ear Cushion Material | Ultra-soft closed-cell foam |
| Headband Construction | Reinforced steel core with adjustable tension |
| Airflow Control™ Technology | Frequency-optimized acoustic damping |
Show next