Empowering Scientific Discovery

AWA6218C Statistical Noise Analyzer

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Zhejiang, China
Manufacturer Type Authorized Distributor
Origin Category Domestic (China)
Model AWA6218C
Pricing Upon Request
Accuracy Class Type 2 per IEC 61672:2002 & GB/T 17181
Microphone 1/2″ Pre-polarized Condenser, Sensitivity ≈ 40 mV/Pa
Frequency Range 20 Hz – 12.5 kHz
Measurement Range 35 dB – 130 dB (optional extended: 27 dB – 120 dB)
Frequency Weighting A-weighting only
Time Weighting Fast (F), Slow (S)
Detector Digital True RMS, Crest Factor ≥ 3
Operating Modes Single-shot, 24-hour Automated Logging
Measured Metrics L<sub>p</sub>, L<sub>inst</sub>, L<sub>5</sub>, L<sub>10</sub>, L<sub>50</sub>, L<sub>90</sub>, L<sub>95</sub>, E (Sound Exposure), L<sub>eq</sub>, L<sub>max</sub>, L<sub>min</sub>
Integration Times Manual, 10 s, 1 min, 5 min, 10 min, 20 min, 1 h, 2 h, 4 h, 8 h, 24 h
Real-time Clock Battery-backed calendar clock with persistent timekeeping during power loss
Data Storage Up to 120 measurement sets with statistical distribution graphs, non-volatile Flash RAM
Interface RS-232 serial port for printer or PC communication
Optional Filters Compatible with AWA5721 (octave-band) or AWA5722 (1/3-octave-band) external filter sets
Printer Support UP40 thermal micro-printer
Power Supply 4 × AA alkaline batteries (≥48 h operation, <20 mA current draw)
Operating Temperature 0 °C to 40 °C (extended range: –10 °C to +50 °C, optional)
Dimensions 220 × 72 × 32 mm
Mass ≈ 0.3 kg

Overview

The AWA6218C Statistical Noise Analyzer is a compact, field-deployable instrument engineered for high-reliability environmental and occupational noise assessment. It implements digital true RMS detection architecture compliant with IEC 61672:2002 and GB/T 17181 requirements for Class 2 sound level meters—ensuring metrological traceability in regulatory and industrial monitoring contexts. Unlike analog-based legacy instruments, its fully digital signal path eliminates drift-related errors and enhances long-term stability under variable ambient conditions. The device functions simultaneously as an integrating sound level meter, personal noise exposure dosimeter, and automated 24-hour environmental logging system. Its core measurement principle relies on real-time digitization of acoustic pressure signals from a pre-polarized 1/2″ condenser microphone, followed by digital filtering, weighting (A-frequency), time-weighting (Fast/Slow), and statistical computation of percentile levels (L5–L95), equivalent continuous sound pressure levels (Leq), and cumulative sound exposure (E). This architecture supports compliance-driven reporting for noise mapping, workplace health surveillance, and municipal environmental noise ordinances.

Key Features

  • Digital true RMS detector with crest factor ≥3, enabling accurate peak capture in impulsive or transient noise environments (e.g., construction, transportation)
  • Battery-backed real-time calendar clock ensuring uninterrupted time-stamping across multi-day deployments without manual re-synchronization
  • Non-volatile Flash RAM storage for up to 120 complete measurement sessions—including full statistical distribution data (e.g., histogram plots, cumulative probability curves) and time-history records
  • Multi-mode operational flexibility: single-point spot measurement, timed integrations (10 s to 24 h), and unattended 24-hour autonomous logging with automatic start/stop scheduling
  • RS-232 interface supporting direct connection to UP40 thermal micro-printers for on-site hardcopy output of Leq, Ldn, Ld/Ln reports, and statistical distribution graphs
  • Modular expandability via external AWA5721 (octave-band) or AWA5722 (1/3-octave-band) filter modules for frequency-domain analysis required in noise source identification and acoustic barrier evaluation
  • Low-power design: ≤20 mA operating current enables >48 hours of continuous use on standard AA alkaline cells; compatible with regulated 5–6 V DC external power supplies for fixed-site installations

Sample Compatibility & Compliance

The AWA6218C is validated for use with standardized 1/2″ pre-polarized condenser microphones meeting IEC 61094-4 specifications. Its A-weighted frequency response (20 Hz–12.5 kHz) conforms to the tolerance limits defined in IEC 61672-1:2013 for Class 2 instruments, making it suitable for statutory noise monitoring under national environmental protection frameworks (e.g., China’s HJ 640–2012, EU Directive 2002/49/EC). The device supports documentation workflows aligned with ISO 1996-2:2017 (acoustics — description, measurement and assessment of environmental noise) and OSHA 1910.95 / NIOSH RELs for occupational exposure assessment. While not inherently 21 CFR Part 11 compliant, its immutable Flash RAM storage and time-stamped audit trail provide foundational data integrity for GLP-aligned field studies when paired with controlled procedural documentation.

Software & Data Management

Data export is facilitated through the RS-232 interface using ASCII-based protocol, allowing seamless integration with third-party data acquisition platforms or custom laboratory information management systems (LIMS). Measurement sets—including Leq, Lmax/Lmin, percentile levels, and integrated exposure values—are structured in tab-delimited format with embedded timestamps and configuration metadata (e.g., weighting, integration time, battery status). No proprietary software is required for basic data retrieval; however, optional companion utilities (distributed separately) support visualization of 24-hour Leq trends, day-night noise indices (Ldn), and spectral overlays when used with external filter modules. All stored datasets retain their original acquisition context—no post-processing interpolation or algorithmic smoothing is applied, preserving raw statistical fidelity for regulatory review.

Applications

  • Long-term ambient noise monitoring at municipal boundaries, near airports, highways, and rail corridors per ISO 1996-2 protocols
  • Ongoing occupational noise exposure assessment in manufacturing, mining, and logistics facilities to verify compliance with national permissible exposure limits (PELs)
  • Acoustic characterization of machinery, HVAC systems, and consumer appliances during product development and quality assurance testing
  • Educational acoustics laboratories requiring portable, standards-compliant instrumentation for student experiments in noise propagation and psychoacoustics
  • Field validation of noise control interventions (e.g., barrier efficacy, enclosure performance) via pre-/post-installation comparative Leq and percentile analysis
  • Research-grade environmental impact assessments where statistical descriptors (L10, L90) inform community annoyance modeling

FAQ

Does the AWA6218C support C- or Z-frequency weighting?
No. The instrument implements A-weighting only, consistent with its Class 2 designation for environmental and occupational noise assessment per IEC 61672.
Can measurement data be exported directly to Excel or CSV without proprietary software?
Yes. The RS-232 ASCII output is plain-text and tab-delimited, enabling direct import into spreadsheet applications or database tools without conversion utilities.
Is the internal clock synchronized to GPS or NTP time sources?
No. The clock is quartz-based with battery backup; manual initialization is required, but time integrity is preserved during battery replacement or power interruption.
What is the maximum sampling interval resolution for 24-hour logging mode?
The device does not perform continuous waveform sampling. Instead, it computes statistical metrics (e.g., Leq, L90) over user-defined integration periods (minimum 10 seconds), with no sub-interval averaging.
Are calibration certificates included with shipment?
Factory calibration against traceable acoustic standards is performed prior to dispatch; a certificate of conformance (not NIST-traceable calibration) is provided. Field recalibration requires a Class 1 pistonphone or sound calibrator per IEC 60942.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0