TimePower TP205 Precision Chilled-Mirror Dew Point Meter

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand TimePower
Origin Beijing, China
Manufacturer Type Direct Manufacturer
Product Category Laboratory-Grade Dew Point Meter
Measurement Principle Chilled-Mirror (Optical Condensation)
Operating Temperature Range −20 °C to +60 °C
Accuracy ±1 °C (at −40 °C to +20 °C)
Repeatability ±0.5 °C
Dew Point Range −100 °C to +20 °C
Sensor Vaisala DMT242 or DMT142 chilled-mirror probe
Response Time (t₆₃% / t₉₀%) 90 s / 450 s
Pressure Range 0–20 bar (absolute)
Sample Flow Rate Flow-Insensitive Design
Output Interface RS232 Serial Port
Power Supply Rechargeable Internal Battery (≥8 h charging time with auto-cut-off protection)
Probe Protection Stainless Steel Sintered Filter
Display True-Color Touchscreen with Dual-Language UI (English & Chinese)
Data Logging Real-Time Storage & Optional Thermal Printing

Overview

The TimePower TP205 Precision Chilled-Mirror Dew Point Meter is a laboratory-grade hygrometric instrument engineered for trace-level moisture analysis in compressed gases and industrial process streams. It operates on the fundamental physical principle of chilled-mirror condensation—where a polished, temperature-controlled mirror surface is dynamically cooled until dew (or frost) forms, detected optically via reflected light intensity change. This primary measurement method provides direct, absolute determination of dew point temperature (Td), eliminating reliance on empirical calibration curves or polymer-based sensors subject to drift. The core sensing element is the Vaisala DMT242 or DMT142 high-stability chilled-mirror probe—internationally recognized for metrological traceability, long-term stability, and resistance to contamination. Designed for rigorous environments, the TP205 delivers certified accuracy of ±1 °C within the −40 °C to +20 °C Td range and ±2 °C across its full −100 °C to +20 °C operational span—meeting requirements for ISO 8573-1 Class 2 and ASTM D6304 Annex A3 validation protocols.

Key Features

  • Chilled-mirror optical detection system with automatic mirror cleaning algorithm and anti-fogging thermal management
  • Integrated stainless steel sintered filter (5 µm pore size) protecting the sensor from particulates, oil aerosols, and condensable hydrocarbons
  • True-color capacitive touchscreen interface supporting real-time bilingual (English/Chinese) operation without firmware switching
  • Simultaneous display of dew point temperature (°C), ppmv water concentration, relative humidity (%RH), and sample temperature (°C)
  • Flow-insensitive measurement architecture—valid across 0.1–20 L/min sample flow rates without recalibration
  • Onboard data logging with timestamped records (≥10,000 entries), exportable via RS232 to PC or external thermal printer
  • Rechargeable lithium-ion battery with intelligent charge management (auto-cutoff after ≥8 h), enabling >12 h continuous field operation

Sample Compatibility & Compliance

The TP205 is validated for use with non-corrosive, non-reactive gas matrices including nitrogen, air, argon, helium, SF6, CO2, natural gas, and purified instrument air. Its stainless-steel wetted path and inert mirror coating ensure compatibility with trace hydrocarbon-bearing streams common in petrochemical and pharmaceutical purge gas monitoring. The instrument complies with IEC 61000-4 electromagnetic immunity standards and meets mechanical robustness requirements per IP54 enclosure rating. While not intrinsically safe, it is suitable for Zone 2/Class I Division 2 environments when operated with appropriate gas conditioning (e.g., particulate filtration, coalescing pre-filters). Data integrity features—including immutable timestamps, user-accessible audit logs, and password-protected configuration settings—support alignment with GLP and GMP documentation practices under FDA 21 CFR Part 11 guidelines where electronic records are retained.

Software & Data Management

Data acquisition and reporting are facilitated through the optional TimePower DewLog PC software (Windows-compatible), which enables automated calibration verification, trend analysis, and PDF report generation compliant with ISO/IEC 17025 documentation templates. All logged measurements include embedded metadata: operator ID, probe serial number, ambient pressure reading, and system self-test status flags. The RS232 interface supports Modbus RTU protocol for integration into SCADA or LIMS platforms. Firmware updates are performed via secure USB-to-serial adapter; each version includes SHA-256 checksum verification to prevent unauthorized modification.

Applications

  • Quality control of compressed air systems in pharmaceutical manufacturing (ISO 8573-1 Class 2–4 verification)
  • Moisture monitoring in SF6 circuit breakers and gas-insulated switchgear (GIS)
  • In-process validation of dry air purges during semiconductor wafer fabrication
  • Trace moisture analysis in LNG carrier cargo tanks and vapor recovery units
  • Calibration reference standard for portable aluminum oxide or tunable diode laser (TDLAS) analyzers
  • Research-grade studies of water vapor thermodynamics in low-temperature gas adsorption experiments

FAQ

What is the calibration traceability of the TP205?
The DMT242/DMT142 probe is factory-calibrated against NIST-traceable chilled-mirror standards; certificate of calibration includes uncertainty budget per ISO/IEC 17025.
Can the TP205 measure below −80 °C dew point?
Yes—the extended range model supports −100 °C Td using cryogenic mirror cooling enhancement; requires optional dry gas purge to prevent frost accumulation on housing.
Is pressure compensation automatic?
Yes—integrated absolute pressure transducer enables real-time dew point correction to standardized 101.325 kPa per ISO 6245.
How often is recalibration recommended?
Annual calibration is advised for routine QC use; biannual verification is sufficient for research applications with documented stability checks.
Does the instrument support MODBUS TCP/IP?
No—only RS232 serial output is provided; Ethernet or wireless connectivity requires external protocol converter.