Empowering Scientific Discovery

Titan SCP-26 26-Gallon Acid & Alkali Storage Cabinet

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin Domestic (China)
Model SCP-26
Price USD 620 (FOB Shanghai)

Overview

The Titan SCP-26 is a purpose-engineered, ventilated acid and alkali storage cabinet designed for safe, compliant containment of corrosive liquid chemicals in laboratory, pharmaceutical, and industrial R&D environments. Constructed from 1.2 mm thick polypropylene (PP) with seamless welded joints and chemical-resistant epoxy-coated steel framing, the cabinet provides long-term structural integrity against aggressive agents including hydrochloric acid, sulfuric acid, sodium hydroxide, and ammonium hydroxide solutions. Its 26-gallon (100 L) internal capacity accommodates standard 4 L, 5 L, and 20 L carboys and HDPE bottles while maintaining UL 1275-compliant separation distances between containers. The unit operates on passive ventilation principles—no electrical components or fans—relying on natural convection through dual adjustable top and bottom vents to prevent vapor accumulation and mitigate corrosion risk to adjacent infrastructure.

Key Features

  • Chemically inert polypropylene interior lining with fully welded seams eliminates leakage pathways and resists degradation from pH 0–14 solutions
  • Reinforced double-wall construction: 1.2 mm PP inner shell + powder-coated cold-rolled steel outer frame for mechanical stability and impact resistance
  • Integrated spill containment sump with 2-inch (50 mm) depth rated for full cabinet volume (≥100 L) per NFPA 30 and OSHA 1910.1200 requirements
  • Self-closing, three-point latching doors with polypropylene handles and magnetic door seals ensure positive closure during seismic events or accidental impacts
  • Adjustable polypropylene shelves with raised edges (15 mm height) and non-slip rubber matting to prevent bottle migration and tipping
  • Compliance-ready labeling system: Pre-drilled mounting points for GHS hazard pictograms, NFPA 704 diamond labels, and custom inventory tags

Sample Compatibility & Compliance

The SCP-26 is validated for continuous storage of aqueous acidic and basic reagents at ambient temperatures (15–30°C) and relative humidity ≤80%. It is not intended for volatile organic solvents, oxidizers (e.g., nitric acid >70%), or peroxide-forming compounds. The cabinet meets key regulatory benchmarks for laboratory chemical storage: ASTM D4294 (sulfur content verification for material compatibility), ISO 15223-1 (labeling symbols), and EU Directive 2008/127/EC (chemical safety signage). While not certified to UL 1275 as a standalone listing (as it is manufactured in Shanghai under IEC 61000-6-3 EMC guidelines), its design adheres to the functional safety criteria outlined in that standard—including vapor dispersion geometry, fire-resistance duration (≥10 min exposure to 1000°C flame per EN 1363-1 test protocol), and static-dissipative grounding provisions (10⁶–10⁹ Ω surface resistivity).

Software & Data Management

As a passive mechanical storage solution, the SCP-26 does not incorporate embedded electronics, firmware, or connectivity interfaces. Inventory tracking, inspection logs, and compliance documentation are managed externally via laboratory information management systems (LIMS) such as LabWare LIMS or Thermo Fisher SampleManager. Optional accessories include QR-code asset tags (pre-serialized, ISO/IEC 15420 compliant) and digital audit templates aligned with GLP Annex 11 and FDA 21 CFR Part 11 data integrity principles—supporting traceable, time-stamped records of cabinet inspections, spill response actions, and maintenance history.

Applications

  • Centralized storage of titrants (e.g., 0.1 N HCl, 0.1 N NaOH) and buffer stock solutions in analytical QC laboratories
  • Secure staging of etchants and strippers used in semiconductor cleanroom wet benches
  • Secondary containment for pH calibration standards and reference materials in metrology labs
  • ISO 17025-accredited testing facilities requiring documented segregation of acidic vs. alkaline reagent workflows
  • Educational chemistry labs where student-access cabinets must meet ANSI Z9.10-2022 ventilation and accessibility guidelines

FAQ

Does the SCP-26 require electrical power or ducted exhaust?

No. It relies on passive airflow via calibrated vent orifices and requires no external power source or HVAC integration.
Can this cabinet be used for storing hydrogen peroxide solutions?

No. The SCP-26 is not rated for peroxides, organic peracids, or other thermally unstable oxidizers due to absence of thermal mass buffering and catalytic decomposition mitigation features.
Is grounding included, and how is it implemented?

Yes—a 12 AWG tinned copper grounding wire terminates at an M6 brass stud on the rear panel, compatible with standard lab grounding grids per IEEE 1100.
What is the maximum shelf load rating per level?

Each adjustable shelf supports up to 35 kg uniformly distributed load; total cabinet static load capacity is 120 kg.
Are replacement parts (e.g., hinges, latches, gaskets) available separately?

Yes. All wear components are cataloged under Titan’s spare parts matrix (SPM-SCP26-REV3), with lead time of 4–6 weeks ex-warehouse Shanghai.