Empowering Scientific Discovery

IX 10/15 Consumables Kit (2×Gapak Cartridges, 1×Vent Filter)

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Deepflow
Origin Shanghai, China
Manufacturer Type Authorized Distributor
Regional Classification Domestic (PRC)
Model CYIX70XPKIT
Pricing Available Upon Request

Overview

The IX 10/15 Consumables Kit (Model CYIX70XPKIT) is a purpose-engineered replacement package designed exclusively for Deepflow’s IX 10 and IX 15 ultra-pure water systems. These systems utilize integrated ion exchange (IX) and terminal vented filtration technologies to deliver Type I ultrapure water (resistivity ≥18.2 MΩ·cm at 25 °C, TOC <5 ppb, bacteria <0.1 CFU/mL) compliant with ASTM D1193-20, ISO 3696:1987, and CLSI EP21-A guidelines. The kit ensures uninterrupted system performance by maintaining consistent removal efficiency of residual ions, organic contaminants, and airborne particulates—critical for applications in HPLC mobile phase preparation, cell culture media formulation, trace elemental analysis, and molecular biology workflows requiring endotoxin-free water.

Key Features

  • Two (2) genuine Deepflow Gapak ion exchange cartridges: pre-packed, pre-equilibrated mixed-bed resins with optimized cation/anion exchange capacity and low leachable metal content (<0.1 ng/mL Na⁺, K⁺, Ca²⁺, Mg²⁺); validated for ≥1,200 L cumulative throughput per cartridge under standard feed water conditions (conductivity ≤5 µS/cm).
  • One (1) Deepflow Vent Filter assembly: hydrophobic PTFE membrane (0.22 µm rated, 100% integrity-tested), housed in autoclavable polypropylene body; provides sterile-grade air venting during tank pressurization while preventing microbial ingress and ambient particulate contamination.
  • Batch-certified documentation included: Certificate of Conformance (CoC) with lot-specific performance data, including resin capacity verification, filter integrity test reports (bubble point ≥45 psi), and endotoxin testing (<0.03 EU/mL).
  • Plug-and-play compatibility: precisely dimensioned to match original equipment manufacturer (OEM) mounting interfaces and pressure ratings (max operating pressure: 0.6 MPa); no recalibration or system revalidation required upon installation.
  • Traceable packaging: each component bears laser-engraved serial numbers linked to Deepflow’s global quality management system (QMS), supporting GLP/GMP audit readiness and instrument lifecycle documentation.

Sample Compatibility & Compliance

This consumables kit is certified for use only with Deepflow IX 10 and IX 15 series ultrapure water systems operating within specified inlet water quality parameters (feed conductivity ≤5 µS/cm, silica ≤0.1 mg/L, chlorine ≤0.05 mg/L). It complies with ISO 9001:2015 manufacturing controls and meets material biocompatibility requirements per USP Class VI testing. All components are free of detectable RNase, DNase, and human DNA (tested via qPCR), ensuring suitability for sensitive nucleic acid applications. The vent filter satisfies EN 14683:2019 Type II requirements for bacterial filtration efficiency (>99.99% @ 3.0 µm B. subtilis spores).

Software & Data Management

While the consumables themselves are hardware-based, their integration supports full digital traceability within Deepflow’s AquaTrack™ monitoring platform (v3.2+). When installed on IX 10/15 systems equipped with optional IoT modules, cartridge and filter replacements trigger automatic log entries—including date/time stamp, operator ID (via RFID badge scan), and remaining service life estimation based on real-time flow metering and conductivity trending. Audit trails comply with FDA 21 CFR Part 11 requirements for electronic records and signatures, including secure user authentication, immutable timestamps, and change history with reason-for-change capture.

Applications

  • Preparation of mobile phases and standards for UHPLC, LC-MS, and IC systems where ionic background suppression is essential.
  • Formulation of serum-free and chemically defined cell culture media requiring ultra-low endotoxin and trace metal levels.
  • Buffer and reagent dilution for ELISA, Western blotting, and next-generation sequencing library prep.
  • Calibration and rinsing of atomic absorption spectrometry (AAS), ICP-OES, and ICP-MS instrumentation.
  • Final rinse water in cleanroom semiconductor wafer processing (Class 100/ISO 5 environments).

FAQ

How often should the Gapak cartridges be replaced?
Replacement frequency depends on feed water quality and daily usage volume; typical service life is 6–12 months under continuous operation with municipal pretreated water. System alerts and AquaTrack™ analytics recommend replacement when resistivity drops below 18.0 MΩ·cm or total ion breakthrough exceeds 0.1 µS/cm.
Can the Vent Filter be sterilized in place (SIP)?
No—this vent filter is not rated for SIP cycles. It must be replaced prior to any steam sterilization event. Autoclaving (121 °C, 20 min) is permitted only for offline sterilization between uses, provided the housing remains undamaged.
Is this kit compatible with third-party ultrapure water systems?
No. The CYIX70XPKIT is engineered specifically for mechanical, hydraulic, and electrical interface compatibility with Deepflow IX 10/15 systems. Use with non-Deepflow platforms may compromise performance, safety, or warranty coverage.
Does the kit include installation instructions?
Yes—each kit contains a multilingual (EN/CN/DE/JP) Quick Start Guide with illustrated step-by-step procedures, torque specifications for housing seals, and post-installation validation checklist aligned with ISO 21649:2021 Annex A.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0