Empowering Scientific Discovery

Titan FO-50 Forced-Air General Purpose Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Titan
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model FO-50
Price USD 785 (FOB Shanghai)

Overview

The Titan FO-50 Forced-Air General Purpose Oven is an engineered thermal processing instrument designed for consistent, uniform heat distribution across laboratory and quality control environments. Utilizing a robust horizontal airflow system with a tangential blower and precisely positioned internal baffles, the FO-50 maintains temperature uniformity within ±1.5 °C across its working chamber—meeting critical requirements for drying, curing, sterilization validation, and stability testing protocols. Its stainless-steel interior chamber (304 grade), double-wall insulated construction, and PID-controlled solid-state relay heating system ensure long-term thermal stability and minimal energy drift over extended operation cycles. The unit operates in ambient-to-250 °C range with 0.1 °C setpoint resolution and complies with IEC 61000-6-3 (EMC) and IEC 61010-1 (safety) standards for laboratory equipment.

Key Features

  • Forced-air convection system with adjustable-speed tangential fan for optimized air velocity and thermal homogeneity
  • Digital PID temperature controller with dual-sensor feedback (working chamber + over-temperature safety cutoff)
  • Stainless-steel (AISI 304) interior chamber and door liner; corrosion-resistant exterior powder-coated steel housing
  • Double-layer glass observation window with integrated anti-fog heater for real-time sample monitoring without thermal disturbance
  • Programmable ramp-soak profiles (up to 10 segments) supporting GLP-compliant thermal process documentation
  • Standard RS-485 interface for integration into centralized lab management systems (Modbus RTU protocol supported)

Sample Compatibility & Compliance

The FO-50 accommodates standard laboratory ware including Petri dishes, weighing boats, glass desiccators, aluminum trays, and polymer test coupons up to 250 mm × 250 mm × 200 mm (W×D×H). Its chamber volume of 50 L supports batch processing of multiple ISO/IEC 17025-compliant reference samples simultaneously. The oven is validated for use in ASTM D1654 (corrosion testing), ISO 17025 clause 6.4.3 (equipment suitability), and USP (sterility assurance process qualification). Optional NIST-traceable calibration certificate (per ISO/IEC 17025) and IQ/OQ documentation packages are available upon request for regulated pharmaceutical and medical device manufacturing environments.

Software & Data Management

The FO-50 includes embedded firmware supporting audit-trail-enabled operation logs, including timestamped start/stop events, temperature deviations >±2 °C, and manual parameter changes. When connected via RS-485 to Titan’s optional LabLink™ Data Acquisition Suite (v3.2), users gain access to real-time graphing, automated CSV export, electronic signature capability, and 21 CFR Part 11-compliant user role management (Admin, Operator, Reviewer). All data files are stored in encrypted SQLite format with SHA-256 hash integrity verification. Firmware updates are delivered via secure HTTPS endpoint with digital signature validation.

Applications

  • Moisture content determination per AOAC 950.46 and ISO 5517
  • Accelerated aging studies for packaging materials (ASTM F1980)
  • Pre-conditioning of polymer specimens prior to tensile or impact testing (ISO 291, ASTM D618)
  • Drying of filter papers and gravimetric analysis substrates in environmental labs
  • Thermal stabilization of reference standards before calibration (e.g., certified reference materials per ISO Guide 35)
  • Residual solvent removal in small-batch R&D synthesis workflows

FAQ

What is the maximum operating temperature of the FO-50?
The FO-50 is rated for continuous operation up to 250 °C. For safety-critical applications requiring extended dwell at ≥220 °C, we recommend specifying the high-temp option (reinforced gasket, upgraded insulation, and Class H motor).

Does the FO-50 support external data logging without LabLink™ software?
Yes—the RS-485 port provides raw Modbus register access. Third-party SCADA or LabVIEW implementations can poll temperature, setpoint, status bits, and alarm flags using standard function codes (03h, 06h).

Is the unit supplied with a factory calibration report?
All units ship with a baseline verification report covering chamber uniformity (9-point grid), sensor linearity (three-point check), and over-temperature cutoff response time. Full ISO/IEC 17025 calibration is available as an add-on service.

Can the FO-50 be installed in a fume hood or ventilated enclosure?
No—it is not designed for negative-pressure environments. Exhaust ducting requires optional rear vent kit (part #FO-VK-50) and must comply with local fire codes for heated air discharge.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0