Empowering Scientific Discovery

Wiseman V-Series Ripple Test Set for High-Voltage DC Power Supplies

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Wiseman
Model V
Max Output Voltage 20 kV
Output Voltage Options 5 / 10 / 15 / 20 kV
Application Ripple Measurement of DC High-Voltage Power Supplies
Compliance ISO 9001:2008 Certified

Overview

The Wiseman V-Series Ripple Test Set is a precision-engineered instrumentation solution designed specifically for quantitative measurement of residual AC ripple superimposed on high-voltage DC power supplies. Operating on the principle of high-impedance, wide-bandwidth differential voltage sensing coupled with calibrated attenuation and signal conditioning, the V-Series enables accurate, repeatable assessment of ripple amplitude (typically expressed as peak-to-peak or RMS values) across the 20 kHz to 10 MHz frequency range—critical for validating stability in sensitive analytical and industrial HV applications. Unlike generic oscilloscope-based methods, this dedicated test set integrates proprietary high-voltage isolation, optimized common-mode rejection, and low-noise front-end circuitry to eliminate measurement artifacts induced by ground loops, capacitive coupling, or EMI—ensuring traceable results compliant with internal quality control protocols and industry-standard validation practices.

Key Features

  • Four standard output voltage ratings: 5 kV, 10 kV, 15 kV, and 20 kV — each configured with matched input impedance and calibrated scaling factors for direct readout
  • Integrated high-voltage probe interface with 1000:1 attenuation ratio and ±1% amplitude accuracy at 25°C (calibrated per IEC 61000-4-30 Class A requirements)
  • Bandwidth of 20 kHz – 10 MHz (–3 dB), supporting detection of switching noise from resonant converters and transient ripple from load-step events
  • Galvanically isolated analog output (0–10 V) and digital RS-485 interface for integration into automated test systems and LIMS environments
  • Rugged, grounded metal enclosure with EN 61010-1 certified creepage/clearance distances and reinforced epoxy insulation for safe operation up to 20 kV DC
  • Designed for long-term stability: temperature coefficient < ±50 ppm/°C; drift < 0.05% FS/1000 h under continuous operation

Sample Compatibility & Compliance

The V-Series is engineered for direct connection to DC high-voltage outputs from laboratory-grade and OEM-integrated power supplies—including but not limited to electrospray ionization (ESI) and atmospheric pressure chemical ionization (APCI) sources used in mass spectrometry systems. It supports compliance verification against key performance criteria defined in ASTM F2327 (Standard Practice for High-Voltage Power Supply Performance Testing), IEC 61326-1 (EMC requirements for laboratory equipment), and internal OEM specifications for ripple ≤ 0.01% of rated output. Units are manufactured under an ISO 9001:2008–certified quality management system, with full traceability of calibration standards (NIST-traceable reference dividers and thermal EMF-compensated measurement chains). Documentation packages include factory calibration certificates, uncertainty budgets, and conformity declarations suitable for GLP/GMP audit readiness.

Software & Data Management

While the V-Series operates as a standalone hardware instrument, its RS-485 interface supports integration with third-party data acquisition platforms via Modbus RTU protocol. Users may log time-stamped ripple waveforms, calculate statistical metrics (e.g., RMS, peak-to-peak, crest factor), and generate pass/fail reports aligned with predefined thresholds. Optional Wiseman-provided LabVIEW VI libraries and Python SDKs facilitate custom scripting for automated qualification testing in regulated environments. All firmware updates are digitally signed and validated; configuration changes are logged with timestamp and user ID to satisfy FDA 21 CFR Part 11 requirements for electronic records and signatures when deployed in pharmaceutical or medical device QC labs.

Applications

  • Verification of ripple performance in ESI and MALDI high-voltage sources prior to mass spectrometer commissioning or routine maintenance
  • OEM validation of DC-DC converter modules for X-ray generators, electron beam systems, and electrostatic precipitators
  • Root-cause analysis of spectral instability or detector saturation linked to power supply noise coupling
  • Design validation of zero-current resonant (ZCR) topologies in next-generation HVPS architectures
  • Calibration support for metrology labs performing accredited high-voltage measurements per ISO/IEC 17025

FAQ

What is the maximum measurable ripple amplitude at 20 kV full scale?
The V-Series supports measurement of ripple components up to ±100 Vpp (with optional extended-range mode) while maintaining linearity and thermal stability.
Can the V-Series be used with pulsed DC outputs?
Yes — its wide bandwidth and fast settling time (< 1 µs) enable accurate capture of ripple during active pulse periods, provided duty cycle and repetition rate fall within specified operating limits.
Is external calibration required after installation?
Factory calibration is valid for 12 months under normal use conditions; annual recalibration is recommended and supported through Wiseman’s global service centers with NIST-traceable standards.
Does the unit include safety interlocks or emergency shutdown capability?
No — the V-Series is a measurement-only device. Safety-critical functions must be implemented externally via the host HVPS or integrated safety relay systems per IEC 61508 SIL-2 guidelines.
How does the V-Series differ from using a standard high-voltage probe with an oscilloscope?
It eliminates probe loading effects, provides built-in common-mode rejection > 80 dB at 1 MHz, and delivers calibrated, noise-immune analog/digital outputs—reducing measurement uncertainty by up to 60% compared to generic probe-based setups.

InstrumentHive