Empowering Scientific Discovery

HePu MWD-700 Microwave Digestion System

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand HePu (Ji'nan, Shandong)
Origin China
Model MWD-700
Sample Capacity 1–18 vessels
Microwave Source Dual Magnetron
Max Operating Temperature 250 °C (up to 300 °C vessel rating)
Max Operating Pressure 0–6 MPa (vessel burst pressure: 20 MPa)
Temperature Measurement Range Ambient–400 °C (±1 °C)
Pressure Measurement Range 0–10 MPa (±0.1 MPa)
Microwave Frequency 2450 MHz
Output Power 0–2500 W (adjustable)
Input Power 3400 W, 220 V AC, 50/60 Hz, 16 A
Cavity Ventilation >5 m³/min corrosion-resistant blower
Microwave Leakage <5 mW/cm² (compliant with GB 10436 and IEC 61000-3-2)

Overview

The HePu MWD-700 Microwave Digestion System is an advanced, fully integrated sample preparation platform engineered for high-throughput, reproducible acid digestion of solid and semi-solid matrices under controlled temperature and pressure conditions. Based on closed-vessel microwave-assisted acid decomposition, the system leverages 2450 MHz electromagnetic energy to rapidly and uniformly heat reaction mixtures—enabling complete mineralization of organic and inorganic samples while minimizing volatile element loss, reagent consumption, and procedural blank contributions. Unlike conventional hotplate or block digesters, the MWD-700 delivers precise kinetic control over digestion thermodynamics via real-time, per-vessel monitoring of temperature and pressure—critical for trace elemental analysis by ICP-OES, ICP-MS, AAS, and HG-AFS. Its robust cavity architecture, dual-magnetron power delivery, and continuous 360° rotation mechanism ensure field homogeneity across all 18 positions, eliminating positional bias and enhancing inter-vessel precision (RSD < 3% for certified reference materials). Designed for routine operation in QA/QC, environmental, food safety, and geochemical laboratories, the MWD-700 complies with ISO 17025 method validation requirements and supports GLP-aligned documentation workflows.

Key Features

  • Zero-consumable vessel design: Eliminates disposable safety components (e.g., burst discs, elastomeric seals, compression rings), reducing long-term operational cost and procurement complexity while maintaining full ASME BPVC Section VIII compliance for pressure containment.
  • Self-resealing digestion vessels: TFM-lined inner vessels with PEEK+glass-fiber reinforced outer jackets automatically restore hermetic integrity after controlled pressure release—ensuring uninterrupted digestion cycles and preventing cross-contamination or sample loss.
  • Independent per-vessel temperature & pressure monitoring: Fiber-optic temperature sensors and piezoresistive pressure transducers provide real-time, non-invasive measurement for each vessel—decoupling sensor systems from aggressive acid environments and enabling true multi-sample parallelism.
  • Continuous 360° rotation platform: Sustained unidirectional rotation eliminates standing-wave interference and ensures uniform microwave coupling across all vessel positions—extending motor service life versus oscillatory (±180°) mechanisms and improving repeatability (CV ≤ 2.1% for Cr in NIST SRM 1573a).
  • Intelligent 10.1-inch color touchscreen interface: Displays live power, temperature, pressure, and time profiles; supports dynamic parameter adjustment during active runs; stores up to 255 customizable methods with 10-step sequences per method—including ramp-hold-cool protocols with user-defined rate limits.
  • Comprehensive safety architecture: Integrates 12 redundant protections: door-interlocked power cutoff, mechanical pressure relief, thermal runaway detection, acoustic anomaly monitoring, emergency stop button, overtemperature/overpressure cut-off, cavity fault diagnostics, and force-engineered explosion-resistant chamber construction.

Sample Compatibility & Compliance

The MWD-700 accommodates standard 100 mL TFM digestion vessels and is validated for use with HNO₃, HCl, HF, H₂O₂, and aqua regia mixtures. It supports digestion of diverse matrices including soil (EPA Method 3052), biological tissues (AOAC 999.10), polymers, coal, catalysts, and lithium-ion battery cathode materials. Vessel materials meet USP Class VI biocompatibility standards and exhibit chemical resistance per ASTM D543. The system conforms to national safety regulations (GB 4706.21, GB 10436) and electromagnetic compatibility directives (IEC 61000-3-2, IEC 61000-4-3). Optional RS232/USB interfaces enable integration with LIMS and support 21 CFR Part 11-compliant audit trails when paired with validated third-party data acquisition software.

Software & Data Management

The embedded operating system provides full method traceability: every run logs vessel ID, setpoints, actual curves, operator ID, timestamp, and system diagnostics. Methods are exportable as CSV or XML for external review. The “Help” module delivers context-sensitive troubleshooting guidance—including pressure calibration verification, temperature drift correction, and cavity cleaning protocols—reducing mean time to resolution (MTTR) by >65% versus vendor-dependent support models. Raw data files include metadata headers compliant with ASTM E1489 for analytical data interchange. Remote monitoring via Ethernet is supported through optional firmware upgrade.

Applications

The MWD-700 serves as a primary digestion tool in accredited testing laboratories performing regulatory analyses per EPA 3052, ISO 11466, EN 13656, and GB/T 223.73. Key application domains include: heavy metal screening in food and cosmetics (Pb, Cd, As, Hg); nutrient and contaminant profiling in agricultural soils and sediments; rare earth element quantification in electronic waste; sulfur and halogen determination in petrochemical feedstocks; and dissolution kinetics studies for pharmaceutical excipients. Its ability to retain volatile analytes (e.g., Se, Te, I) at elevated temperatures makes it particularly suited for speciation-preparatory workflows prior to HPLC-ICP-MS coupling.

FAQ

What is the maximum number of samples the MWD-700 can process simultaneously?

The system supports parallel digestion of 1 to 18 samples using standardized 100 mL TFM vessels.

Does the MWD-700 comply with international microwave safety standards?

Yes—it meets IEC 61000-3-2 for harmonic emissions and maintains microwave leakage below 5 mW/cm² at 5 cm distance, conforming to GB 10436 and ICNIRP guidelines.

Can digestion methods be modified during an active run?

Yes—the touchscreen interface allows real-time adjustment of temperature, pressure, power, and hold time without interrupting the cycle.

Is the system compatible with HF-based digestion protocols?

Yes—TFM vessels and PEEK+glass-fiber outer jackets are chemically inert to hydrofluoric acid up to 250 °C and 6 MPa.

What data export formats are supported?

CSV and XML exports include full method parameters, raw sensor outputs, and system event logs for traceability and regulatory reporting.