Empowering Scientific Discovery

ILMVAC VCB 521 Vacuum Controller

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Origin Germany
Manufacturer Type Authorized Distributor
Origin Category Imported
Model VCB 521
Pricing Upon Request
Measurement Range 1100–1 mbar
Accuracy ±2 mbar
Display Digital & Icon-Based (9 mm digit height)
Operating Voltage 230 V AC / 50 Hz
Protection Class IP20
Ambient Temperature Range 15–40 °C
Weight 1.5 kg
Dimensions (W×H×D) 195 × 178 × 105 mm
Vacuum Port Front-mounted hose connection, DN 8
Interface RS232 PC interface
Chemical Resistance High (chemically resistant housing and internal components)

Overview

The ILMVAC VCB 521 Vacuum Controller is an integrated, compact vacuum regulation system engineered for precision pressure management in laboratory-scale distillation, rotary evaporation, freeze drying, and solvent recovery applications. Unlike standalone vacuum gauges or mechanical regulators, the VCB 521 combines piezoresistive pressure sensing, proportional electromagnetic valve actuation, real-time digital feedback control, and intuitive local operation into a single self-contained unit. Its core architecture follows closed-loop PID-based control logic, enabling dynamic adjustment of vacuum level in response to process-induced pressure fluctuations—critical for maintaining consistent boiling points during temperature-sensitive evaporative separations. Designed and assembled in Germany, the device complies with CE marking requirements and meets essential safety and electromagnetic compatibility (EMC) directives (2014/30/EU and 2014/35/EU), ensuring reliable integration into GLP-compliant laboratory environments.

Key Features

  • Integrated pressure sensing and active vacuum regulation within one enclosure—eliminates need for external controllers, transducers, or solenoid manifolds.
  • Wide operational range of 1100 to 1 mbar (absolute), covering rough vacuum applications from atmospheric pre-pump down through medium vacuum regimes typical of rotary evaporators and short-path distillations.
  • Digital display with 9 mm high LED digits and status icons for immediate visual verification of setpoint, actual pressure, valve position, and error conditions.
  • High chemical resistance achieved via fluoropolymer-sealed internal components and a robust ABS+PC housing rated for exposure to common organic solvents, acids, and bases encountered in synthetic and analytical labs.
  • RS232 serial interface (DB9) enables bidirectional communication with Windows-based laboratory software for remote setpoint programming, data logging, and audit-trail generation—fully compatible with 21 CFR Part 11-ready systems when deployed with compliant host software.
  • Front-mounted DN 8 vacuum port with standardized hose barb simplifies installation onto existing vacuum lines; no tools required for connection or disconnection.
  • Compact footprint (195 × 178 × 105 mm) and low mass (1.5 kg) allow flexible benchtop placement—even on space-constrained rotary evaporator frames or fume hood interiors.

Sample Compatibility & Compliance

The VCB 521 is compatible with all standard laboratory vacuum pumps operating within its pressure range—including diaphragm, scroll, and oil-lubricated rotary vane pumps—and interfaces seamlessly with glassware systems using ISO-KF, NW, or standard rubber hose connections (via optional adapters). Its pressure sensor exhibits minimal hysteresis and long-term zero stability, validated per DIN EN 61298-2 for industrial pressure measurement devices. While not certified to ISO/IEC 17025 as a standalone metrological instrument, the controller supports traceable calibration workflows when used with NIST-traceable reference gauges. It conforms to IEC 61000-6-2 (immunity) and IEC 61000-6-4 (emissions), and its IP20 rating indicates suitability for indoor laboratory use under non-dusty, non-splashing conditions per IEC 60529.

Software & Data Management

The VCB 521 communicates via ASCII protocol over RS232 at 9600 baud, 8N1 configuration. Standard command sets support reading real-time pressure values (e.g., “READ?”), setting target vacuum levels (“SET 50.0”), querying valve status (“VALVE?”), and retrieving device identification (“IDN?”). Third-party integration is supported through LabVIEW™ drivers, Python (pySerial), and MATLAB® Serial Port Toolbox. When connected to validated LIMS or ELN platforms, logged vacuum profiles—including timestamps, setpoints, deviations, and valve duty cycles—can be archived with electronic signatures and version-controlled metadata, satisfying ALCOA+ principles for data integrity in regulated QC/QA labs.

Applications

  • Precision-controlled rotary evaporation of thermolabile compounds (e.g., cannabinoids, fragrances, pharmaceutical intermediates).
  • Optimized solvent recovery in multi-step synthesis workflows where consistent vapor pressure directly impacts yield and purity.
  • Stabilized vacuum conditions during fractional distillation of low-boiling azeotropes.
  • Automated vacuum ramping in lyophilization pre-freeze stages to prevent melt-back or collapse.
  • Method development for ASTM D287-20 (API gravity of crude oil) and USP <721> (viscosity determination under controlled pressure).

FAQ

What vacuum pumps are compatible with the VCB 521?

The controller works with any pump capable of reaching ≤1 mbar absolute pressure and delivering sufficient flow rate to maintain the selected setpoint under process load—commonly diaphragm (e.g., KNF N86 KT), scroll (e.g., Agilent IDP-10), or two-stage rotary vane pumps.
Can the VCB 521 be calibrated in-house?

Yes—using a certified reference gauge connected in parallel, users may perform zero and span adjustments via the front-panel service menu. Full calibration certificates require traceability to national standards and are available through ILMVAC-authorized service centers.
Is the RS232 interface optically isolated?

No—the interface is galvanically coupled. For electrically noisy environments, use a USB-to-RS232 adapter with built-in isolation or install a signal conditioner inline.
Does the VCB 521 support analog output for PLC integration?

Not natively. Analog 0–10 V or 4–20 mA outputs are not provided; however, digital pressure data can be converted externally using industrial protocol gateways (e.g., Modbus RTU via RS485 converter).
What maintenance intervals are recommended?

Inspect hose connections and valve seal integrity every 6 months; clean display and housing with isopropanol-dampened lint-free cloth. No scheduled internal maintenance is required under normal operating conditions (15–40 °C, non-condensing atmosphere).

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0