Yoyilab DHG-9023A Precision Forced-Air Constant-Temperature Drying Oven

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Yoyilab
Origin Shanghai, China
Manufacturer Type Direct Manufacturer
Country of Origin China
Model DHG-9023A
Instrument Category Precision Drying Oven
Temperature Range RT+10°C to 280°C
Temperature Uniformity ±2.5% (at 100°C)
Temperature Fluctuation ±1°C
Temperature Resolution 0.1°C
External Dimensions 625 × 540 × 500 mm
Internal Chamber Dimensions 340 × 330 × 320 mm
Internal Chamber Material Mirror-Finish Stainless Steel (SUS304)
Heating Method Forced-Air Circulation via Rear-Mounted Centrifugal Blower
Power Input AC 220 V, 50 Hz, 850 W
Working Environment Ambient Temperature 5–40°C, Relative Humidity ≤80% RH (non-condensing)
Standard Compliance GB/T 30435–2013

Overview

The Yoyilab DHG-9023A is a precision forced-air constant-temperature drying oven engineered for reproducible thermal processing in research laboratories, quality control environments, and industrial R&D settings. It operates on the principle of convective heat transfer enhanced by a rear-mounted centrifugal blower and optimized air duct architecture, ensuring rapid temperature recovery and high spatial uniformity across the working chamber. Designed in strict accordance with GB/T 30435–2013 (the Chinese national standard for electric heating drying ovens), the DHG-9023A delivers stable thermal performance under both static and dynamic load conditions. Its operational range spans from ambient +10°C to 280°C—covering critical applications including moisture removal, polymer curing, pharmaceutical stability testing, pre-weighing sample conditioning, and low-temperature sterilization protocols where steam-free dry heat is required.

Key Features

  • Microprocessor-based intelligent temperature controller with PID algorithm, offering precise setpoint regulation, real-time display of chamber temperature, and programmable timer (1–9999 minutes).
  • Robust dual-layer tempered glass observation window with large viewing area, enabling non-intrusive visual monitoring without thermal disturbance.
  • High-efficiency forced-air circulation system featuring adjustable airflow direction and rear-mounted intake/exhaust ports—automatically expelling residual moisture and maintaining consistent internal humidity profiles.
  • Chamber constructed from mirror-finish SUS304 stainless steel; outer casing fabricated from cold-rolled steel with electrostatic epoxy-polyester powder coating for corrosion resistance and mechanical durability.
  • High-temperature silicone door gasket ensures reliable sealing up to 280°C, minimizing thermal leakage and extending service life.
  • Configurable safety architecture: independent over-temperature cut-off circuit (optional), power-loss data retention with auto-restart function, and audible/visual alarm activation upon deviation beyond user-defined thresholds.
  • Modular interface support: RS485 communication port (optional), embedded thermal printer (optional), 25 mm / 50 mm test port kits (optional), and inert gas inlet with calibrated rotameter (optional) for oxygen-sensitive or pyrophoric sample handling.

Sample Compatibility & Compliance

The DHG-9023A accommodates a broad spectrum of sample types—including petri dishes, weighing boats, glassware, metal trays, polymer films, ceramic substrates, and electronic components—within its 20 L working volume. Its stainless-steel interior resists oxidation and facilitates cleaning between runs, supporting GLP-compliant workflows. While not certified to ISO/IEC 17025 or FDA 21 CFR Part 11 out-of-the-box, the instrument’s deterministic thermal response, traceable calibration points, and optional data logging interfaces enable integration into validated laboratory systems. Users performing regulated work (e.g., USP , ASTM E2019, or ICH Q1A(R2) stability studies) may configure the oven with optional multi-segment programmable controllers and audit-trail-capable software to meet documentation requirements.

Software & Data Management

When equipped with the optional RS485 interface and companion PC software, the DHG-9023A supports bidirectional parameter configuration, real-time temperature logging at configurable intervals (1 s to 60 min), and export of time-stamped CSV datasets compatible with LIMS platforms and statistical process control tools. The embedded printer option provides hard-copy records of setpoints, actual temperatures, elapsed time, and alarm events—critical for batch release documentation and internal QA audits. All firmware retains parameter memory during power interruption, preserving user-defined configurations and eliminating manual re-entry after utility failures.

Applications

  • Drying and conditioning of analytical samples prior to gravimetric analysis (e.g., moisture content per ASTM D2231 or ISO 787-2).
  • Baking of coated substrates, printed circuit boards, and thin-film sensors under controlled thermal ramping.
  • Thermal aging studies of elastomers, adhesives, and composite materials per ASTM D573 or ISO 188.
  • Pre-sterilization of glassware and metal instruments using dry heat at ≥160°C for ≥2 hours (validated per ISO 17665-1).
  • Dehydration of botanical specimens, food matrices, and soil samples without oxidative degradation.
  • Low-temperature curing of encapsulants, conformal coatings, and solder pastes in electronics manufacturing.

FAQ

What is the maximum recommended operating temperature for continuous use?
The DHG-9023A is rated for continuous operation up to 280°C. For extended-duration tests above 250°C, periodic verification of door seal integrity and chamber uniformity is advised.

Does the oven support ramp-hold programming?
Standard configuration includes single-setpoint operation with timer. Multi-segment ramp-and-soak capability is available via the optional programmable temperature controller (sold separately).

Is calibration certificate included with shipment?
A factory calibration report referencing NIST-traceable standards is provided. Full ISO/IEC 17025 calibration services can be arranged through authorized third-party labs upon request.

Can the oven be used under inert atmosphere?
Yes—when fitted with the optional inert gas inlet kit (including stainless steel fitting, pressure regulator, and calibrated rotameter), users may purge and maintain nitrogen or argon environments within the chamber.

What maintenance is required to ensure long-term accuracy?
Biannual inspection of blower motor performance, door gasket compression, and sensor drift against a reference thermometer is recommended. Cleaning of air filters and exhaust vents should occur after each high-residue application.